China Underground 2.5 Mm PVC / SWA Cable 0.6-1kv Voltage ROSH Certificate
China Underground 2.5 Mm PVC / SWA Cable 0.6-1kv Voltage ROSH Certificate

  1. China Underground 2.5 Mm PVC / SWA Cable 0.6-1kv Voltage ROSH Certificate
  2. China Underground 2.5 Mm PVC / SWA Cable 0.6-1kv Voltage ROSH Certificate

Underground 2.5 Mm PVC / SWA Cable 0.6-1kv Voltage ROSH Certificate

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 100KM/Week
Delivery Time 7-15 working days
Packaging Details Steel wooden drum, Coil In Foil / Drum
Model name YJV
Voltage Suitable 0.6/1kV
Conductor Material Copper
certificates IEC, ROSH
Sheath Color Black or upon requirement
Conductor Type Bare Copper Class 2
Sheath PVC
Application Industrial, underground
Brand Name DONGJIAXIN
Model Number YJV
Certification IEC, ROSH
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 100KM/Week
Delivery Time 7-15 working days Packaging Details Steel wooden drum, Coil In Foil / Drum
Model name YJV Voltage Suitable 0.6/1kV
Conductor Material Copper certificates IEC, ROSH
Sheath Color Black or upon requirement Conductor Type Bare Copper Class 2
Sheath PVC Application Industrial, underground
Brand Name DONGJIAXIN Model Number YJV
Certification IEC, ROSH Place of Origin CHINA
High Light 0.6 kv swa cable1kv swa cableROSH 2.5 mm swa cable

YJV / YJV22 /YJLV /YJLV22 /zr cable 0.6/1KV 3+2 cores CU/AL/XLPE/PVC/SWA cable

Construction:

Stranded (RM) bare copper as per IEC60228
XLPE (cross-linked polyethylene) Insulation
Fillers strip, Yarn, or Paper
Non woven Wrapping tape or Flame Retardant

Extruded PVC Inner Covering

Overall Sheath: polyvinylchloride (PVC)

Application:


Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.

 

Technical data:
Test voltage 0.6/1 kV [kV] 3.5 / 5 min.
Temperature range in motion -5°C till +70°C
fixed -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard EN 60332-1-2


Standards:

IEC 60502-1

 

 

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 5.2 12.1
1×2.5 1 0.7 1.4 5.6 7.41
1×4 1 0.7 1.4 6.0 4.61
1×6 1 0.7 1.4 6.5 3.08
1×10 7 0.7 1.4 7.6 1.83
1×16 7 0.7 1.4 8.6 1.15
1×25 7 0.9 1.4 10.2 0.727
1×35 7 0.9 1.4 11.2 0.524
1×50 10 1.0 1.4 12.5 0.387
1×70 14 1.1 1.4 14.3 0.268
1×95 19 1.1 1.5 16.5 0.193
1×120 24 1.2 1.5 18.2 0.153
1×150 30 1.4 1.6 20.1 0.124
1×185 37 1.6 1.6 22.2 0.0991
1×240 48 1.7 1.7 24.9 0.0754
1×300 61 1.8 1.8 27.5 0.0601
1×400 61 2.0 1.9 30.8 0.0470
1×500 61 2.2 2.0 34.3 0.0366
1×630 61 2.4 2.2 41.3 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 8.9 12.1
2×2.5 1 0.7 1.8 9.7 7.41
2×4 1 0.7 1.8 10.6 4.61
2×6 1 0.7 1.8 11.6 3.08
2×10 7 0.7 1.8 13.8 1.83
2×16 7 0.7 1.8 15.7 1.15
2×25 7 0.9 1.8 18.9 0.727
2×35 7 0.9 1.8 20.9 0.524
2×50 10 1.0 1.8 24.6 0.387
2×70 14 1.1 1.8 28.2 0.268
2×95 19 1.1 1.9 32.4 0.193
2×120 24 1.2 2.0 35.8 0.153
2×150 30 1.4 2.2 39.6 0.124
2×185 37 1.6 2.3 44.0 0.0991
2×240 48 1.7 2.5 49.4 0.0754
2×300 61 1.8 2.6 54.3 0.0601
2×400 61 2.0 2.9 61.0 0.0470
2×500 61 2.2 3.1 68.4 0.0366
2×630 61 2.4 3.3 82.0 0.0283
3×1.5 1 0.7 1.8 9.4 12.1
3×2.5 1 0.7 1.8 10.2 7.41
3×4 1 0.7 1.8 11.2 4.61
3×6 1 0.7 1.8 12.2 3.08
3×10 7 0.7 1.8 14.6 1.83
3×16 7 0.7 1.8 16.7 1.15
3×25 7 0.9 1.8 20.1 0.727
3×35 7 0.9 1.8 22.3 0.524
3×50 10 1.0 1.8 26.2 0.387
3×70 14 1.1 1.9 30.3 0.268
3×95 19 1.1 2.0 34.6 0.193
3×120 24 1.2 2.1 38.5 0.153
3×150 30 1.4 2.3 42.6 0.124
3×185 37 1.6 2.4 47.3 0.0991
3×240 48 1.7 2.6 53.1 0.0754
3×300 61 1.8 2.7 58.2 0.0601
3×400 61 2.0 3.0 65.6 0.0470
3×500 61 2.2 3.2 73.5 0.0366
3×630 61 2.4 3.5 88.2 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 10.1 12.1
4×2.5 1 0.7 1.8 11.0 7.41
4×4 1 0.7 1.8 12.1 4.61
4×6 1 0.7 1.8 13.3 3.08
4×10 7 0.7 1.8 16.0 1.83
4×16 7 0.7 1.8 18.3 1.15
4×25 7 0.9 1.8 22.1 0.727
4×35 7 0.9 1.8 24.6 0.524
4×50 10 1.0 1.8 28.8 0.387
4×70 14 1.1 2.0 33.4 0.268
4×95 19 1.1 2.1 38.4 0.193
4×120 24 1.2 2.3 43.0 0.153
4×150 30 1.4 2.4 47.3 0.124
4×185 37 1.6 2.6 52.7 0.0991
4×240 48 1.7 2.8 59.0 0.0754
4×300 61 1.8 3.0 65.1 0.0601
4×400 61 2.0 3.3 73.3 0.0470
4×500 61 2.2 3.5 82.0 0.0366
4×630 61 2.4 3.8 98.6 0.0283
5×1.5 1 0.7 1.8 10.9 12.1
5×2.5 1 0.7 1.8 11.9 7.41
5×4 1 0.7 1.8 13.1 4.61
5×6 1 0.7 1.8 14.5 3.08
5×10 7 0.7 1.8 17.4 1.83
5×16 7 0.7 1.8 20.0 1.15
5×25 7 0.9 1.8 24.3 0.727
5×35 7 0.9 1.8 27.0 0.524
5×50 10 1.0 1.9 31.9 0.387
5×70 14 1.1 2.1 36.9 0.268
5×95 19 1.1 2.2 42.5 0.193
5×120 24 1.2 2.4 47.5 0.153
5×150 30 1.4 2.6 52.5 0.124
5×185 37 1.6 2.8 58.4 0.0991
5×240 48 1.7 3.0 65.5 0.0754
5×300 61 1.8 3.2 72.3 0.0601
5×400 61 2.0 3.5 81.2 0.0470
5×500 61 2.2 3.8 91.2 0.0366
5×630 61 2.4 4.1 109.5 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 10.8 7.41
3×4+1×2.5 1 0.7 1.8 11.8 4.61
3×6+1×4 1 0.7 1.8 13.0 3.08
3×10+1×6 7 0.7 1.8 15.3 1.83
3×16+1×10 7 0.7 1.8 17.7 1.15
3×25+1×16 7 0.9 1.8 21.2 0.727
3×35+1×16 7 0.9 1.8 23.0 0.524
3×50+1×25 10 1.0 1.8 27.4 0.387
3×70+1×35 14 1.1 1.9 31.5 0.268
3×95+1×50 19 1.1 2.1 36.1 0.193
3×120+1×70 24 1.2 2.2 40.5 0.153
3×150+1×70 30 1.4 2.3 43.8 0.124
3×185+1×95 37 1.6 2.5 49.2 0.0991
3×240+1×120 48 1.7 2.6 55.0 0.0754
3×300+1×150 61 1.8 2.8 60.5 0.0601
3×400+1×185 61 2.0 3.1 68.1 0.0470
3×500+1×240 61 2.2 3.3 76.3 0.0366
3×630+1×300 61 2.4 3.6 90.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 11.5 7.41
3×4+2×2.5 1 0.7 1.8 12.6 4.61
3×6+2×4 1 0.7 1.8 13.9 3.08
3×10+2×6 7 0.7 1.8 16.2 1.83
3×16+2×10 7 0.7 1.8 19.0 1.15
3×25+2×16 7 0.9 1.8 22.6 0.727
3×35+2×16 7 0.9 1.8 24.2 0.524
3×50+2×25 10 1.0 1.8 29.1 0.387
3×70+2×35 14 1.1 2.0 33.3 0.268
3×95+2×50 19 1.1 2.1 38.2 0.193
3×120+2×70 24 1.2 2.3 43.3 0.153
3×150+2×70 30 1.4 2.4 46.3 0.124
3×185+2×95 37 1.6 2.5 52.0 0.0991
3×240+2×120 48 1.7 2.7 58.1 0.0754
3×300+2×150 61 1.8 2.9 64.2 0.0601
3×400+2×185 61 2.0 3.2 72.1 0.0470
3×500+2×240 61 2.2 3.5 80.9 0.0366
3×630+2×300 61 2.4 3.8 94.7 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 0.7 1.8 11.7 7.41
4×4+1×2.5 1 0.7 1.8 12.9 4.61
4×6+1×4 1 0.7 1.8 14.2 3.08
4×10+1×6 7 0.7 1.8 16.8 1.83
4×16+1×10 7 0.7 1.8 19.5 1.15
4×25+1×16 7 0.9 1.8 23.4 0.727
4×35+1×16 7 0.9 1.8 25.6 0.524
4×50+1×25 10 1.0 1.9 30.6 0.387
4×70+1×35 14 1.1 2.0 35.0 0.268
4×95+1×50 19 1.1 2.2 40.5 0.193
4×120+1×70 24 1.2 2.3 45.3 0.153
4×150+1×70 30 1.4 2.5 49.4 0.124
4×185+1×95 37 1.6 2.6 55.2 0.0991
4×240+1×120 48 1.7 2.9 61.9 0.0754
4×300+1×150 61 1.8 3.1 68.3 0.0601
4×400+1×185 61 2.0 3.4 76.7 0.0470
4×500+1×240 61 2.2 3.6 86.0 0.0366
4×630+1×300 61 2.4 3.9 102.1 0.0283

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

 

 

FAQ

* How to assure the quality of products?

1. Most of our products have certification.

2. Our Lab staff will test the material and check the process card before production.

3. The O.D tester is testing all the time during production, and the production line is always under control.

4. The product will be tested by Lab staff after production.

* Do you offer free samples or not?

1. If we have inventory about the sample you need and the total amount is not large, it's free.

2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.

* When I want customized products, how to do it?

We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

Copper Cable ZR YJV22 0.6/1kv XLPE Insulated Steel Tape Armoured FR PVC Underground Power Cable
▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

▼ Delivery Port :

Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 5 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 6 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 7
Port of Shenzhen Port of Hongkong

Port of Guangzhou
 

 

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

Tag:   fireproof electrical cable,    fire rated electrical cable,    fire resistant power cable

Ordering Advice:

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

If this all seems a little too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1990

  • Total Annual:

    230701800.00-307602400

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in... DJX Cable was first founded in 1990 and formally registered in 2003 as Shenzhen Dongjiaxin Wire&Cable co.,ltd.. In 2017, DJX established a group company Shenzhen Finecredit Group Co.,ltd. and started a group operation model with 4 wholly-owned subsidiaries. Group manufacturing base is located in...

+ Read More

Get in touch with us

  • Reach Us
  • SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
  • No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
  • https://www.industrialelectricalcable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement