Payment Terms | T/T |
Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days |
Packaging Details | In Carton or Wooden Box |
Product Name | 40mm Electromagnetic Flow Meter with Water, 60 Degree |
Pipeline Diameter | DN40 |
Accuracy | 0.5% |
Output | 4-20mA / Pulse / RS485 |
Electrode | 316SS, Hc, Ta, Ti, Others |
IP Class | IP65/IP68 |
Brand Name | |
Model Number | MLF |
Place of Origin | China |
View Detail Information
Explore similar products
Compact Type Electromagnetic Flow Meter SS Material with 0.3 - 10m/s Velocity
Thread Type Magnetic Flow Transmitter High Performance Fast Response Design
Clamp Type Electromagnetic Flow Meter Stainless Steel with 220VAC / 24VDC /
Electromagnetic Flow Meter with English / Korean / Polish / Turkish / French /
Product Specification
Payment Terms | T/T | Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days | Packaging Details | In Carton or Wooden Box |
Product Name | 40mm Electromagnetic Flow Meter with Water, 60 Degree | Pipeline Diameter | DN40 |
Accuracy | 0.5% | Output | 4-20mA / Pulse / RS485 |
Electrode | 316SS, Hc, Ta, Ti, Others | IP Class | IP65/IP68 |
Brand Name | Model Number | MLF | |
Place of Origin | China | ||
High Light | 40mm Electromagnetic Flow Meter ,IP65 Electromagnetic Flow Meter ,20mA Electromagnetic Flow Meter |
40mm Electromagnetic Flow Meter with Water, 60 Degree
1.Working Principle
The principle of the sensor is based on Faraday’s law of electromagnetic induction.
It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and produces induced electromagnetic force.Which can be measured by the two electrodes on the meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal) E=KBDV
E——Induced electromotive force,V;
K——meter constant;
B——Magnetic flux density,T;
D——Internal diameter of measuring pipe,m;
V——Average velocity of pipe section,m/s.
MLF Series Electromagnetic Flow Meter
Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,
K is meter constant,K=4kB/πD.
Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the measuring electrodes inspect the electromotive force, and transmit to the converter, the converter provides excitation current.
E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,adjusting can be achieved.
2. Selection of Liner Material
Liner Material | Main Performance | Application |
PTFE | 1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone. 2. Low abrasion resistance. 3. Low negative pressure resistance | 1. -25~140℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare medium |
CR | Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc. | 1. <80℃ 2. Be able to measure sewage and mud |
PU | 1. Very good abrasive resistance, flexibility. 2. Low acid and alkali resistance. | 1. <65℃ 2. Neutral strong abrasion resistance medium |
Hard Rubber | 1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide 2 Avoid strong oxidants | 1. <80℃ 2. General acid, alkali, salt solution |
PFA | 1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant. 2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 3. Injection molding for higher negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
FEP(F46) | 1. Hydrophobicity and non-viscous 2. Corrosion resistance is inferior to PFA 3. Negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
3. Dimensional Sketches
a. Dimension of Converter
Divided Type
Integrated Type
Battery Powered Type
b. Dimension of Sensor
Pipeline Diameter | Dimension | ||
L | W | H | |
15 | 160 | 95 | 130 |
20 | 160 | 105 | 137 |
25 | 160 | 115 | 150 |
32 | 160 | 135 | 160 |
40 | 200 | 145 | 175 |
50 | 200 | 160 | 185 |
65 | 200 | 180 | 205 |
80 | 200 | 195 | 215 |
100 | 250 | 215 | 235 |
125 | 250 | 245 | 275 |
150 | 300 | 280 | 300 |
200 | 350 | 335 | 355 |
250 | 400 | 400 | 405 |
300 | 500 | 455 | 460 |
350 | 500 | 515 | 520 |
400 | 600 | 575 | 580 |
450 | 600 | 635 | 630 |
500 | 600 | 710 | 685 |
600 | 600 | 835 | 795 |
700 | 700 | 905 | 910 |
800 | 800 | 1020 | 1030 |
900 | 900 | 1120 | 1120 |
1000 | 1000 | 1245 | 1250 |
1200 | 1200 | 1465 | 1470 |
4. Configuration
MLF Series Electromagnetic Flow Meter Configuration | |||||||||||||||||||||||
Model | MLF | ||||||||||||||||||||||
Sensor Installation | S | Flange Type Sensor | |||||||||||||||||||||
C | Insertion Type Sensor | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipeline Diameter | 10 | 10mm | |||||||||||||||||||||
15 | 15mm | ||||||||||||||||||||||
20 | 20mm | ||||||||||||||||||||||
...... | |||||||||||||||||||||||
2000 | 2000mm | ||||||||||||||||||||||
Electrode Installation | F | Standard Fixed Type | |||||||||||||||||||||
Electrode Material | A | 316L SS | |||||||||||||||||||||
B | Hb | ||||||||||||||||||||||
C | Ta | ||||||||||||||||||||||
D | Ti | ||||||||||||||||||||||
E | Hc | ||||||||||||||||||||||
F | Tungsten Carbide | ||||||||||||||||||||||
G | Others | ||||||||||||||||||||||
Liner Material | R | Rubber | |||||||||||||||||||||
P | PTFE | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipe Material | B | 304 SS (Standard) | |||||||||||||||||||||
C | 316 SS | ||||||||||||||||||||||
Flange Type | G | GB (Standard) | |||||||||||||||||||||
A | ANSI | ||||||||||||||||||||||
J | JIS | ||||||||||||||||||||||
B | BS | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Flange Material | A | 304 SS | |||||||||||||||||||||
B | 316 SS | ||||||||||||||||||||||
C | #20 Carbon Steel (Standard) | ||||||||||||||||||||||
Cover Material | D | 304 SS | |||||||||||||||||||||
E | 316 SS | ||||||||||||||||||||||
F | Carbon Steel+ Epoxy Metallic Paint (Standard) | ||||||||||||||||||||||
Matching Flange | 0 | Without Matching Flange (Standard) | |||||||||||||||||||||
1 | With Matching Flange | ||||||||||||||||||||||
Ground Ring | 0 | Without Ground Ring (Standard) | |||||||||||||||||||||
1 | With Ground Ring | ||||||||||||||||||||||
Rated Pressure | 10 | 1.0MPa | |||||||||||||||||||||
16 | 1.6MPa | ||||||||||||||||||||||
25 | 2.5MPa | ||||||||||||||||||||||
40 | 4.0MPa | ||||||||||||||||||||||
Working Temperature | E | ≤60℃ | |||||||||||||||||||||
H | ≤180℃(Divided Type) | ||||||||||||||||||||||
Type | I | Integrated Type | |||||||||||||||||||||
D | Divided Type | ||||||||||||||||||||||
Output | P | Pulse | |||||||||||||||||||||
A | 4-20mA | ||||||||||||||||||||||
G | RS485 | ||||||||||||||||||||||
H | Hart | ||||||||||||||||||||||
Q | Others | ||||||||||||||||||||||
Power Supply | 0 | 220VAC | |||||||||||||||||||||
1 | 24VDC | ||||||||||||||||||||||
2 | Battery-powered | ||||||||||||||||||||||
Protection Class | 0 | IP65 (Integrated/Divided Type) | |||||||||||||||||||||
1 | IP67 (Divided Type) | ||||||||||||||||||||||
2 | IP68 (Divided Type) | ||||||||||||||||||||||
Other Features | R | Heat Energy Function | |||||||||||||||||||||
P | With PT1000 | ||||||||||||||||||||||
B | Without PT1000 | ||||||||||||||||||||||
Explosion Proof | 0 | None | |||||||||||||||||||||
EX | Explosive Proof |
5.Instrument Inspection and Maintenance
Electromagnetic flow converter has self-diagnosis function. In addition to the power and hardware circuit fault, The system also give alarm to other faults in general usage. These information are given accordingly prompts in the lower right of the screen.
1. Maintenance and repair
a) Sensor installation site should be consistent with the section four requirements, Please keep the housing clean and tidy;
b)Transmitter should be placed in a clean, ventilated, dry place;
c)Need to inspect every two years, for high precision users, instrument need to be submitted to censorship.
2. Transportation and storage
a)The instrument must be packed before transportation, be carefully handled when loading and unloading.
b)Storage site must be dry, ventilated, avoid corrosive gas erosion, the ambient temperature is not too low or too high;
c)Storage time better not exceed three years.
3,Unpacking and checking
a) The packing can’t be opened with heavy hammer, and should be careful not to damage the instrument
b) Check the content carefully according to the packing list.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2019
Total Annual:
$1000000-$2000000
Employee Number:
>50
Ecer Certification:
Site Member
Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ...
Get in touch with us
Leave a Message, we will call you back quickly!