China factories

China factory - Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

  • China,Shanghai ,Shanghai
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China IP67 4.0MPa PTFE Liner Electromagnetic Flow Meter
China IP67 4.0MPa PTFE Liner Electromagnetic Flow Meter

  1. China IP67 4.0MPa PTFE Liner Electromagnetic Flow Meter
  2. China IP67 4.0MPa PTFE Liner Electromagnetic Flow Meter

IP67 4.0MPa PTFE Liner Electromagnetic Flow Meter

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 500pcs per month
Delivery Time 7-10 working days
Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter
Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2%
Flange GB/ANSI/JIS/BS/Others
Pressure Rate 0.6MPa-4.0MPa
IP Class IP65/IP67/IP68
Brand Name
Model Number MLF
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 500pcs per month
Delivery Time 7-10 working days Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2% Flange GB/ANSI/JIS/BS/Others
Pressure Rate 0.6MPa-4.0MPa IP Class IP65/IP67/IP68
Brand Name Model Number MLF
Place of Origin China
High Light PTFE Liner Electromagnetic Flow MeterIP67 Electromagnetic Flow Meter4.0MPa Mag Flow Meter

                                     Melan Brand MLF Model Electromagnetic Flow Meter with PTFE Liner

 

1. Introduction

The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a converter. Used to measure the conductivity of liquids or solids. Under normal circumstances, its conductivity should be greater than 5μS/cm (the conductivity of tap water and raw water is about 100-500μS/cm), and it can also be used to measure acids, alkali, brine, pulp or pulp and other media. But these media cannot contain a lot of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.

 

2. Quick Details

1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2) MLF electromagnetic flowmeter is explosion-proof design.

3) Function of low conductivity measurement.

4) There are nine language(Chinese, English, Korean, Polish, Turkish, French and Portuguese language) options to meet the needs of different customers.

5) It has the function of self-regulation and self-examination.

6) Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

 

3. Selection of Liner Material

Liner Material Main Performance Application
PTFE

1 The most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong bases and various organic solvents, but not resistant to the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

2 Low wear resistance.

3 Low negative pressure resistance.

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CR Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Room temperature resistance, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

4. Selection of Electrode Materials

Electrode Material Main Performance
316L Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.
Hb

Good resistance to all concentrations below boiling point of hydrochloric acid, but also resistant to non-oxidizing acids, alkalis, sulphuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.

Hc Corrosion resistance to oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulphuric acid, oxidizing salts, such as Fe3 plus, Q3 plus, and other oxidants, such as a mixture of hyalphate solutions and seawater above normal temperatures.
Ti Resistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.
Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and  can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......  
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others  
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa  
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

 

 

7. Instrument inspection and maintenance

 

Electromagnetic flow meters have a self-diagnosis function. In addition to power and hardware circuit failures, the system also alerts to other faults in general use. This information is prompted in the lower right corner of the screen.

 

1 Maintenance and repair

a) The sensor installation site should comply with section IV requirements, please keep the housing clean;

b) The transmitter should be placed in a clean, ventilated and dry place;

c) The instrument needs to be checked every two years and for high-precision users, the instrument needs to be submitted for review.

 

2 Transport and storage

a) The instrument must be packed before transport and handled with care.

b) Storage sites must be dry and ventilated to avoid the erosion of corrosive gases, and the ambient temperature should not be too low or too high;

c) Storage time should preferably not exceed three years.

 

3 Out-of-the-box inspection

a) The package cannot be opened with a heavy hammer and care should be taken not to damage the instrument

b) Check the contents carefully according to the packing slip.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement