China Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC
China Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC

  1. China Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC
  2. China Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC

Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10000pcs per month
Delivery Time 7-10 working days
Packaging Details In Carton Packing
Product Name Hydrostatic Level Transmitter
Accuracy ±0.2% or ±0.1%
Measuring Range 0~200mH2O
Sensor Stainless Steel(Cylinder Shape)
Lag Full Span Better Than 0.01%
Product Types Common, Oil Resistance, Corrosion Resistance
Brand Name
Model Number ML2000T
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10000pcs per month
Delivery Time 7-10 working days Packaging Details In Carton Packing
Product Name Hydrostatic Level Transmitter Accuracy ±0.2% or ±0.1%
Measuring Range 0~200mH2O Sensor Stainless Steel(Cylinder Shape)
Lag Full Span Better Than 0.01% Product Types Common, Oil Resistance, Corrosion Resistance
Brand Name Model Number ML2000T
Place of Origin China
High Light liquid level transmitterhydrostatic type level transmitter

                                   Industry Hydrostatic Type Level Transmitter Two - wired Analog 24VDC

 

1. Introduction

ML2000T series static liquid level transmitter adopts imported silicon pressure transducer as sensitive element, utilizing reasonable industry structure to finish stainless steel sealing package. The amplifying circuit can ensure measurement accuracy through laser compensation . The electrical connection cable applies is anti corrosive gas shielded cable which makes the back pressure chamber is directly connected to the atmosphere. 

 

2. Features

  • The tested medium is extensive. As long as the liquid is compatible with the diaphragm material and the paste, it can be measured.
  • The lifetime is long for it has stainless steel material, reasonable sealing package and special cable.
  • It has high accuracy and good stability. The transducer realizes temperature compensation with 0-85℃ and eliminates accuracy influence caused by temperature drift through compensation circuit.
  • ML2000T series is easy installed. Just immerse the probe into medium directly and connect the signal cable to secondary instrument. Adapt to small installation space. When installation, please try to fix the cable to avoid shaking of transducer for shaking can influence the accuracy and lifetime of the transducer.
  • Upgrade features:

① Power supply non polar connection

② Field or Outside lightning prevention design

 

 

3. Technical Parameter

Accuracy ±0.2% or ±0.1%
Measuring Range 0~200mH2O
Stability <0.1%FS Per Year
Overload Limit 200%
Power Supply 24VDC or 12VDC
Signal Output Two-wired 4-20mA
Overload Limit 150%~300%
Lag Full Span Better Than 0.01%
Working Temperature 0~85℃
Storage Temperature 85℃

 

 

4. Structure & Material

Isolation Diaphragm 316L Stainless Steel
Transducer: Stainless Steel(Cylinder Shape)
Sealing: Fluorine Rubber
Cable: PVC Cable With Shield
Product Types Common, Oil Resistance, Corrosion Resistance

 

 

5. Configuration

Type Specification Code Illustration
ML2¨¨¨T --------------------------------- Static Liquid Level Transmitter
Transducer 0-------------------------------- Diffused Silicon Transducer
Accuracy 8-------------------------------- ±0.2%
5-------------------------------- ±0.1%
Output 8-------------------------------- 4-20mA
1-------------------------------- 4-20mA, HART, RS485
  T--------------------------------  
Measuring Mode A-------------------------------- Common Type *
G-------------------------------- Oil Resistance Type(0~200℃)
N-------------------------------- Corrosion Resistance Type
K-------------------------------- Lightning Stroke Resistance Type
Dimension Requirements L-------------------------------- Cable Type (Note 1)
G-------------------------------- Rod Type (Note 2)
Measuring Range 1-------------------------------- 0-1000mmH2O
2-------------------------------- 0-5000mmH2O
3-------------------------------- 0-10000mmH2O
4-------------------------------- 0-20000mmH2O
5-------------------------------- 0-30000mmH2O
6-------------------------------- 0-60000mmH2O
7-------------------------------- 0-100mH2O
8-------------------------------- 0-150mH2O
9-------------------------------- 0-200mmH2O
Display Header D-------------------------------- Multiple Parameters & Modes Digital LED Display Header With HART
L-------------------------------- Common LED Header Without HART
Z-------------------------------- Pointer Header
N-------------------------------- No Header
Electrical Connection 5-------------------------------- M20x1.5 Waterproof Concentrator
Power Supply -A-------------------------------- 24VDC
-B-------------------------------- 12VDC
Additional Type -FL------------------------------ Flange Connection (Note 3)
-NF1---------------------------- Ex-proof Certificate: Exd II CT6
-NS1---------------------------- Intrinsic Safety Type: Exi II CT4
-M------------------------------- Other Requirements (Note 4)
Remarks:    
e.g.:ML2088TAL2N5-A-NF1 0-5000mmH2O
Note1: Please indicate cable length behind type if you choose this code
Note2: Please indicate rod length behind type if you choose this code(Max.3m)
Note3: Please indicate flange size behind type if you choose this code
Note4: Please note in order
*: Standard    
Order Attention:    
1. Indicate the ambient temperature and medium temperature if it is corrosive.
2. Indicate medium density.

 

 

6. Installation Method:

(1) Choose a place easy to operate and maintain to install.

(2) Try to be away from the vibration source

(3) Try to be away from the heat source

(4) Better to connect the pipe with the valves

(5) Please clamp on the six-party of the wrench tightly

(6) Please don’t move the connection part between Hirschmann and outer cover.

 

7. Pressure Level Transmitter

   Gauge Pressure Transmitter

   Differential Pressure Transmitter

   Capacitance Level Transmitter

   Hydrostatic Level Transmitter

   Submersible Level Transmitter

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement