China factories

China factory - Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

  • China,Shanghai ,Shanghai
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China High Accuracy Electromagnetic Flow Transmitter Low Conductivity Measurement
China High Accuracy Electromagnetic Flow Transmitter Low Conductivity Measurement

  1. China High Accuracy Electromagnetic Flow Transmitter Low Conductivity Measurement
  2. China High Accuracy Electromagnetic Flow Transmitter Low Conductivity Measurement

High Accuracy Electromagnetic Flow Transmitter Low Conductivity Measurement

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 500pcs per month
Delivery Time 7-10 working days
Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter
Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2%
Flange GB/ANSI/JIS/BS/Others
Output Hart, RS485, Profibus, 4-20mA, Frequency, Pulse
IP Class IP65/IP67/IP68
Brand Name
Model Number MLF
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 500pcs per month
Delivery Time 7-10 working days Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2% Flange GB/ANSI/JIS/BS/Others
Output Hart, RS485, Profibus, 4-20mA, Frequency, Pulse IP Class IP65/IP67/IP68
Brand Name Model Number MLF
Place of Origin China
High Light mag flow meterelectronic magnetic flow meter

                               High Accuracy Electromagnetic Flow Meter Low Conductivity Measurement

 

1. Introduction

MLF electromagnetic flowmeter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. Generally, its conductivity should be greater than 5μS/cm (the conductivity of tap water, raw water is about 100~500μS/cm). it can also be used to measure various media such as acid, alkali, brine, pulp or pulp and other medium. But these medium can not contain a large number of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument to measure liquid fluidity. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textile, food, urban management, water plants and other industries of flow measurement.

 

2. Features

MLF electromagnetic flowmeter is explosion-proof design.

Function of low conductivity measurement.

There are nine languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

It has the function of self-regulation and self-examination.

Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

 

 

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

 

4. Selection of Electrode Materials

Electrode Material Main Performance
316L

Good corrosion resistance to nitric acid, less than 5% corrosion of sulfuric acid, acetic acid, alkaline liquid, sulfite, seawater and acetic acid under certain pressure at room temperature, and can be widely used in petrochemical urea, vinylon and so on

Hb

Good resistance to hydrochloric acid with concentration lower than boiling point and corrosion of non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

Hc

Corrosion of oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3,Q3, and some other oxidants, such as a mixture of hypochlorite solution and seawater above normal temperature.

Ti Resistance the corrosion of seawater, various chlorides, hypochlorite, oxidizing acid(including fuming nitric acid), and organic acid or alkali, but don't be resistance to the corrosion of pure reducint acid(like sulfuric acid, hydrochloric acid). But if acid includes oxidants(like nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

 

6. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......  
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others  
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa  
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

 

7. Instrument Detection & Maintenance

 

Electromagnetic Flowmeter has self-diagnosis function. In addition to power and hardware circuit failures, the system also alarm other faults in general use. The information is prompted in the lower right corner of the screen.

 

1. Maintenance and repair

a) sensor installation site should meet the requirements of Section 4, please keep the shell clean;

b) transmitters shall be placed in a clean, ventilated, dry place;

c) need to be checked every two years, for high-precision users, the instrument needs to be submitted for review.

 

2. Transport and storage

a) instruments must be packed before transportation, loading and unloading should be carefully light.

b) storage place must be dry, ventilated, avoid corrosive gas erosion, environmental temperature should not be too low or too high;

c) storage time should not exceed three years.

 

3. Open-box inspection

a) packing must not be opened with a heavy hammer, be careful not to damage the instrument

b) carefully check the contents according to the packing list.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement