Payment Terms | T/T |
Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days |
Packaging Details | In Carton or Wooden Box |
Product Name | Electro Magnetic Flow Meter |
Pipeline Diameter | DN150 |
Accuracy | Up to 0.2% |
Flange | GB/ANSI/JIS/BS/Others |
Velocity | 0.3~10m/s |
Output | Hart, RS485, Profibus, 4-20mA, Frequency, Pulse |
Brand Name | |
Model Number | MLF |
Place of Origin | China |
View Detail Information
Explore similar products
Digital Industrial Flow Meter 4-20mA Output DN4-DN200 Pipeline Diameter
High Accuracy Turbine Water Flow Meter Stainless Steel 304 Body Double Power
Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart
Reliable Industrial Flow Meter Convenient Insertion Type Magnetic Flow Meter
Product Specification
Payment Terms | T/T | Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days | Packaging Details | In Carton or Wooden Box |
Product Name | Electro Magnetic Flow Meter | Pipeline Diameter | DN150 |
Accuracy | Up to 0.2% | Flange | GB/ANSI/JIS/BS/Others |
Velocity | 0.3~10m/s | Output | Hart, RS485, Profibus, 4-20mA, Frequency, Pulse |
Brand Name | Model Number | MLF | |
Place of Origin | China | ||
High Light | insertion type magnetic flow meter , vortex air flow meter |
Integrated Electromagnetic Industrial Flow Meter 4 Inch Modbus RS485
1. Introduction
The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a transducer. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μS/cm (tap water, raw water conductivity of about 100 ~ 500μS/cm), can also be used to measure acid, alkali, salt water, pulp or pulp and other media. However, these media should not contain large amounts of magnetic material and air bubbles.
MLF electromagnetic flowmeter is a kind of instrument to measure liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries flow measurement.
2. Quick Details
The MLF electromagnetic flow meter is for explosive proof design.
It has the function of low conductivity measurement.
It has 9 languages for option to satisfy different customers’ requirements.
It has the function of self-adjustment and self-checking.
A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.
3. Specification
MLF Type | Divided Type | Integrated Type | Explosive Proof Integrated Type | Battery Powered Type | Heat Energy Type |
Accuracy | ±0.2% or ±0.5% | ||||
Pipeline Diameter | DN10-DN2000 | DN10-DN600 | DN25-DN2000 | ||
Flange | GB, ANSI, JIS, BS, Others | ||||
Pressure | DN10-DN600 1.0 1.6 2.5 4.0MPa | ||||
DN700-DN2000 0.6 1.0 1.6MPa | |||||
Liner Material | CR, PTFE, PU, Hard Rubber, PFA, FEP(F46) | ||||
Conductivity | ≥5µs/cm(Please contact us if it is less than 5µs/cm) | ||||
Electrode | 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others | ||||
Protection Class | IP65, IP66, IP67, IP68 | ||||
Medium Temperature | -25~180℃ (Please refer to liner material) | -25~80℃(Please refer to liner material) | -25~180℃ (Please refer to liner material) | ||
Ambient Temperature for Accuracy Influence | <±0.1%/10℃ or <±0.25%/10℃ at the ambient temperature of -25~60℃ | ||||
Repetability | ≤±0.1% or ±0.25% | ||||
Analog Output Error | ≤±0.02mA | ||||
Velocity | 0.3~10m/s | ||||
Electrical connection | M20x1.5 Seal Cartridge, GB1/2, NPT1/2 | ||||
Output | 4-20mA, Pulse, RS485, Hart, Profibus |
4. Selection of Electrode Materials
Electrode Material | Main Performance |
316L | Good corrosion resistance of nitric acid, <5% sulfuric acid, acetic acid, alkaline liquid normal temperature, sulfite, seawater, acetic acid under certain pressure, can be widely used in petrochemical urea, vinylon and so on. |
Hb | Good resistance to all concentrations below the boiling point of hydrochloric acid, but also resistant to non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion. |
Hc | Corrosion of oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3,Q3, and some other oxidants, such as a mixture of hypochlorite solution and seawater above normal temperature. |
Ti | Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease. |
Ta | Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid. |
Pt-Ir | Have good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium |
Tungsten Carbide | For pulp and sewage, good resistance to solid particle interference. |
5. Selection of Liner Material
Liner Material | Main Performance | Application |
PTFE | 1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion. 2 Low wear resistance. 3 Low negative pressure resistance. | 1. -25~140℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare medium |
CR | Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc. | 1. <80℃ 2. Be able to measure sewage and mud |
PU | 1. Very good abrasive resistance, flexibility. 2. Low acid and alkali resistance. | 1. <65℃ 2. Neutral strong abrasion resistance medium |
Hard Rubber | 1. Good resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide 2. Avoid strong oxidants | 1. <80℃ 2. General acid, alkali, salt solution |
PFA | 1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant. 2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 3. Injection molding for higher negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
FEP(F46) | 1. Hydrophobicity and non-viscous 2. Corrosion resistance is inferior to PFA 3. Negative pressure | 1. 40~180℃ 2. Strong corrosion medium, like strong acid and alkali 3. Healthcare mdium |
5. Dimensional Sketches
a. Dimension of Converter
Divided Type
Integrated Type
Battery Powered Type
b. Dimension of Sensor
Pipeline Diameter | Dimension | ||
L | W | H | |
15 | 160 | 95 | 130 |
20 | 160 | 105 | 137 |
25 | 160 | 115 | 150 |
32 | 160 | 135 | 160 |
40 | 200 | 145 | 175 |
50 | 200 | 160 | 185 |
65 | 200 | 180 | 205 |
80 | 200 | 195 | 215 |
100 | 250 | 215 | 235 |
125 | 250 | 245 | 275 |
150 | 300 | 280 | 300 |
200 | 350 | 335 | 355 |
250 | 400 | 400 | 405 |
300 | 500 | 455 | 460 |
350 | 500 | 515 | 520 |
400 | 600 | 575 | 580 |
450 | 600 | 635 | 630 |
500 | 600 | 710 | 685 |
600 | 600 | 835 | 795 |
700 | 700 | 905 | 910 |
800 | 800 | 1020 | 1030 |
900 | 900 | 1120 | 1120 |
1000 | 1000 | 1245 | 1250 |
1200 | 1200 | 1465 | 1470 |
6. Configuration
MLF Series Electromagnetic Flow Meter Configuration | |||||||||||||||||||||||
Model | MLF | ||||||||||||||||||||||
Sensor Installation | S | Flange Type Sensor | |||||||||||||||||||||
C | Insertion Type Sensor | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipeline Diameter | 10 | 10mm | |||||||||||||||||||||
15 | 15mm | ||||||||||||||||||||||
20 | 20mm | ||||||||||||||||||||||
...... | |||||||||||||||||||||||
2000 | 2000mm | ||||||||||||||||||||||
Electrode Installation | F | Standard Fixed Type | |||||||||||||||||||||
Electrode Material | A | 316L SS | |||||||||||||||||||||
B | Hb | ||||||||||||||||||||||
C | Ta | ||||||||||||||||||||||
D | Ti | ||||||||||||||||||||||
E | Hc | ||||||||||||||||||||||
F | Tungsten Carbide | ||||||||||||||||||||||
G | Others | ||||||||||||||||||||||
Liner Material | R | Rubber | |||||||||||||||||||||
P | PTFE | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Pipe Material | B | 304 SS (Standard) | |||||||||||||||||||||
C | 316 SS | ||||||||||||||||||||||
Flange Type | G | GB (Standard) | |||||||||||||||||||||
A | ANSI | ||||||||||||||||||||||
J | JIS | ||||||||||||||||||||||
B | BS | ||||||||||||||||||||||
O | Others | ||||||||||||||||||||||
Flange Material | A | 304 SS | |||||||||||||||||||||
B | 316 SS | ||||||||||||||||||||||
C | #20 Carbon Steel (Standard) | ||||||||||||||||||||||
Cover Material | D | 304 SS | |||||||||||||||||||||
E | 316 SS | ||||||||||||||||||||||
F | Carbon Steel+ Epoxy Metallic Paint (Standard) | ||||||||||||||||||||||
Matching Flange | 0 | Without Matching Flange (Standard) | |||||||||||||||||||||
1 | With Matching Flange | ||||||||||||||||||||||
Ground Ring | 0 | Without Ground Ring (Standard) | |||||||||||||||||||||
1 | With Ground Ring | ||||||||||||||||||||||
Rated Pressure | 10 | 1.0MPa | |||||||||||||||||||||
16 | 1.6MPa | ||||||||||||||||||||||
25 | 2.5MPa | ||||||||||||||||||||||
40 | 4.0MPa | ||||||||||||||||||||||
Working Temperature | E | ≤60℃ | |||||||||||||||||||||
H | ≤180℃(Divided Type) | ||||||||||||||||||||||
Type | I | Integrated Type | |||||||||||||||||||||
D | Divided Type | ||||||||||||||||||||||
Output | P | Pulse | |||||||||||||||||||||
A | 4-20mA | ||||||||||||||||||||||
G | RS485 | ||||||||||||||||||||||
H | Hart | ||||||||||||||||||||||
Q | Others | ||||||||||||||||||||||
Power Supply | 0 | 220VAC | |||||||||||||||||||||
1 | 24VDC | ||||||||||||||||||||||
2 | Battery-powered | ||||||||||||||||||||||
Protection Class | 0 | IP65 (Integrated/Divided Type) | |||||||||||||||||||||
1 | IP67 (Divided Type) | ||||||||||||||||||||||
2 | IP68 (Divided Type) | ||||||||||||||||||||||
Other Features | R | Heat Energy Function | |||||||||||||||||||||
P | With PT1000 | ||||||||||||||||||||||
B | Without PT1000 | ||||||||||||||||||||||
Explosion Proof | 0 | None | |||||||||||||||||||||
EX | Explosive Proof |
7. Product Photos
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2019
Total Annual:
$1000000-$2000000
Employee Number:
>50
Ecer Certification:
Site Member
Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ...
Get in touch with us
Leave a Message, we will call you back quickly!