Payment Terms | T/T |
Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days |
Packaging Details | In Carton or Wooden Box |
Product Name | Turbine Flow Meter |
Connection | Thread Type |
Medium Temperature | -20℃~+110℃ |
Pipeline Diameter | DN4-DN200 |
Protection Class | IP65 |
Accuracy | ±1%R、±0.5%R、±0.2%R(Special Order) |
Brand Name | |
Model Number | LWGYML |
Place of Origin | China |
View Detail Information
Explore similar products
Digital Industrial Flow Meter 4-20mA Output DN4-DN200 Pipeline Diameter
High Accuracy Turbine Water Flow Meter Stainless Steel 304 Body Double Power
Remote Type Liquid Electronic Magnetic Flow Meter With RS485 / Hart
Reliable Industrial Flow Meter Convenient Insertion Type Magnetic Flow Meter
Product Specification
Payment Terms | T/T | Supply Ability | 500pcs per month |
Delivery Time | 7-10 working days | Packaging Details | In Carton or Wooden Box |
Product Name | Turbine Flow Meter | Connection | Thread Type |
Medium Temperature | -20℃~+110℃ | Pipeline Diameter | DN4-DN200 |
Protection Class | IP65 | Accuracy | ±1%R、±0.5%R、±0.2%R(Special Order) |
Brand Name | Model Number | LWGYML | |
Place of Origin | China | ||
High Light | insertion type magnetic flow meter ,vortex air flow meter |
Stainless Steel Industrial Flow Meter / Turbine Water Meter IP65
1. Introduction
LWGYML series intelligent liquid turbine Flowmeter is a new intelligent instrument which integrates turbine flow sensor and display. It is developed by using advanced ultra-low power single chip microcomputer technology. Compact structure, clear reading, high reliability, no external power interference, lightning protection, low cost and other obvious advantages.
2. Features
3. Working Principle
The working principle of the turbine Flowmeter: the fluid flows through the sensor housing. Because the blade of the impeller has a certain angle with the flow direction, the impulse force of the fluid causes the blade to have a rotating torque, and the blade rotates after overcoming the friction torque and fluid resistance. the speed is stable after the moment is balanced, and under certain conditions, the rotational speed is proportional to the velocity, because the blade has magnetic conductivity. It is in the magnetic field of the signal detector (composed of permanent magnet steel and coil). The rotating blade cuts the magnetic force line and periodically changes the magnetic flux of the coil, so that the two ends of the coil induce an electric pulse signal. This signal is amplified and shaped by the amplifier to form a continuous rectangular pulse wave with a certain amplitude, which can be transmitted to the display instrument, showing the instantaneous flow and accumulation of the fluid.
4. Specifications
Pipeline Diameter(mm) and Connection | 4,6,10,15,20,25,32,40 Thread Connection |
(15,20,25,32,40) 50,65,80,100,125,150,200 Flange Connection | |
Accuracy | ±1%R,±0.5%R,±0.2%R(Special Order) |
Turn Down Ratio | 10:1; 15:1; 20:1 |
Material | 304SS,316(L)SS, etc |
Medium Temperature | -20℃~+110℃ |
Environmental Conditions | Temperature: -10℃~+55℃ Relative humidity: 5%~90% Atmospheric pressure: 86~106KPa |
Power supply | Sensor:+12VDC,+24VDC(Option) Transmitter:+24VDC Local Display:3.2V Lithium Battery |
Output Signal | Sensor:Pulse Frequency Signal(Low level≤0.8V, High level≥8V) Transmitter:Two Wired 4-20mA Current Signal |
Signal Cable | STVPV 3x0.3(Three Wired),2x0.3(Two Wired) |
Signal Cable Connection | Houseman Connector(Standard Type) Inner Thread M20x1.5(Explosion Type) |
Transmission Distance | ≤1000m |
Explosion Proof | None(Standard Type) EXdIIBT6(Explosion Proof) |
Protection Class | IP65 |
5. Flow Range & Work Pressure
Pipeline Diameter | Normal Flow Range (m³/h) | Extended Flow Range (m³/h) | Normal Pressure (MPa) | Pressure Rate(MPa) (Flange Connection) |
DN4 | 0.04~0.25 | 0.04~0.40 | 6.3 | 12,16,25 |
DN6 | 0.10~0.60 | 0.06~0.60 | 6.3 | 12,16,25 |
DN10 | 0.20~1.20 | 0.15~1.50 | 6.3 | 12,16,25 |
DN15 | 0.60~6.00 | 0.40~8.00 | 6.3,2.5 (Flange Connection) | 4.0,6.3,12,16,25 |
DN20 | 0.80~8.00 | 0.45~9.00 | 6.3,2.5 (Flange Connection) | 4.0,6.3,12,16,25 |
DN25 | 1.00~10.00 | 0.50~10.00 | 6.3,2.5 (Flange Connection) | 4.0,6.3,12,16,25 |
DN32 | 1.50~15.00 | 0.80~15.00 | 6.3,2.5 (Flange Connection) | 4.0,6.3,12,16,25 |
DN40 | 2.00~20.00 | 1.00~20.00 | 6.3,2.5 (Flange Connection) | 4.0,6.3,12,16,25 |
DN50 | 4.00~40.00 | 2.00~~40.00 | 2.5 | 4.0,6.3,12,16,25 |
DN65 | 7.00~70.00 | 4.00~70.00 | 2.5 | 4.0,6.3,12,16,25 |
DN80 | 10.00~100.00 | 5.00~100.00 | 2.5 | 4.0,6.3,12,16,25 |
DN100 | 20.00~200.00 | 10.00~200.00 | 1.6 | 4.0,6.3,12,16,25 |
DN125 | 25.00~250.00 | 13.00~250.00 | 1.6 | 2.5,4.0,6.3,12,16 |
DN150 | 30.00~300.00 | 15.00~300.00 | 1.6 | 2.5,4.0,6.3,12,16 |
DN200 | 80.00~800.00 | 40.00~800.00 | 1.6 | 2.5,4.0,6.3,12,16 |
6. Installation Dimension
According to the diameter, choose thread or flange connection to install the senor. As to installation method, please check Pic4, Pic5, Pic6.
Pic4 LWGYML-4~10 Structure & Installation Dimension Diagram
Pic5 LWGYML-15~40 Structure & Installation Dimension Diagram
Pic6 LWGYML-50~200 Structure & Installation Dimension Diagram
Pipeline Diameter | L | Thread Connection | Flange Connection | ||
(mm) | G | D (mm) | d (mm) | n | |
DN4 | 295 | G1/2 | |||
DN6 | 330 | G1/2 | |||
DN10 | 450 | G1/2 | |||
DN15 | 75 | G1 | θ65 | θ14 | 4 |
DN20 | 80 | G1 | θ75 | θ14 | 4 |
DN25 | 100 | G1-1/4 | θ85 | θ14 | 4 |
DN32 | 120 | G2 | θ100 | θ14 | 4 |
DN40 | 140 | G2 | θ110 | θ18 | 4 |
DN50 | 150 | θ125 | θ18 | 4 | |
DN65 | 170 | θ145 | θ18 | 4 | |
DN80 | 200 | θ160 | θ18 | 8 | |
DN100 | 220 | θ180 | θ18 | 8 | |
DN125 | 250 | θ210 | θ25 | 8 | |
DN150 | 300 | θ250 | θ25 | 8 | |
DN200 | 360 | θ295 | θ25 | 12 |
7. Configuration
LWGYML Series Turbine Flow Meter Configuration | ||||||||||
Model | LWGYML | |||||||||
Pipe Material | 4 | 4mm | ||||||||
6 | 6mm | |||||||||
10 | 10mm | |||||||||
...... | ||||||||||
200 | 200mm | |||||||||
Model Description | N | No Display,12VDC Power Supply,Pulse Output, High Level≥8V Low Level≤0.8V | ||||||||
A | No Display,4-20mA 2 Wired Current Output | |||||||||
B | Local Display,Battery Operated | |||||||||
C | Local Display,4-20mA 2 Wired Current Output | |||||||||
C1 | Local Display,RS485 Output | |||||||||
C2 | Local Display, HART Output | |||||||||
Accuracy | 05 | 0.5 Grade | ||||||||
10 | 1.0 Grade | |||||||||
Turbine Type | W | Extended Ratio | ||||||||
S | Standard Ratio | |||||||||
Material | S | SS 304 | ||||||||
I | SS 316(L) | |||||||||
Explosion Proof | N | None | ||||||||
E | Explosion Type(ExmIICT6 or ExdIIBT6) | |||||||||
Pressure Rate | N | Normal Pressure | ||||||||
H | High Pressure | |||||||||
Connection Type | T | Thread Connection | ||||||||
F | Flange Connection | |||||||||
Filter | N | None | ||||||||
F | With Filter |
8. Details
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2019
Total Annual:
$1000000-$2000000
Employee Number:
>50
Ecer Certification:
Site Member
Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments. Our products are widely used in various fields, including electricity, chemical ...
Get in touch with us