China Smart Electromagnetic Flow Meter Wastewater Flow Meter
China Smart Electromagnetic Flow Meter Wastewater Flow Meter

  1. China Smart Electromagnetic Flow Meter Wastewater Flow Meter
  2. China Smart Electromagnetic Flow Meter Wastewater Flow Meter
  3. China Smart Electromagnetic Flow Meter Wastewater Flow Meter
  4. China Smart Electromagnetic Flow Meter Wastewater Flow Meter
  5. China Smart Electromagnetic Flow Meter Wastewater Flow Meter
  6. China Smart Electromagnetic Flow Meter Wastewater Flow Meter

Smart Electromagnetic Flow Meter Wastewater Flow Meter

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T
Supply Ability 500pcs per month
Delivery Time 7-10 working days
Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter
Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2%
Flange GB/ANSI/JIS/BS/Others
Velocity 0.3~10m/s
Liner Material Rubber/PTFE/PU/Hard Rubber/PFA/FEP(F46)
Power Supply 220VAC/24VDC/Lithium Battery
Type & IP Grade Integrated Type IP65/Remote Type IP68
Pressure Rate 0.6MPa~4.0MPa
Model Number MLF
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 500pcs per month
Delivery Time 7-10 working days Packaging Details In Carton or Wooden Box
Product Name Electromagnetic Flow Meter Pipeline Diameter DN15-DN2000
Accuracy Up to 0.2% Flange GB/ANSI/JIS/BS/Others
Velocity 0.3~10m/s Liner Material Rubber/PTFE/PU/Hard Rubber/PFA/FEP(F46)
Power Supply 220VAC/24VDC/Lithium Battery Type & IP Grade Integrated Type IP65/Remote Type IP68
Pressure Rate 0.6MPa~4.0MPa Model Number MLF
Place of Origin China

                                                             Smart Electromagnetic Flow Meter Wastewater Flow Meter

 

1. Introduction

MLF electromagnetic flowmeter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. Generally, its conductivity should be greater than 5μS/cm (the conductivity of tap water, raw water is about 100~500μS/cm). it can also be used to measure various media such as acid, alkali, brine, pulp or pulp and other medium. But these medium can not contain a large number of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument to measure liquid fluidity. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textile, food, urban management, water plants and other industries of flow measurement.

 

2. Quick Details

1) It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

2) MLF electromagnetic flowmeter is explosion-proof design.

3) Function of low conductivity measurement.

4) There are nine language(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

5) It has the function of self-regulation and self-examination.

6) Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

 

 

3. Selection of Liner Material

Liner Material Main Performance Application
PTFE

1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

2 Low wear resistance.

3 Low negative pressure resistance.

1. -25~140℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare medium

CR Oil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

1. <80℃

2. Be able to measure sewage and mud

PU

1. Very good abrasive resistance, flexibility.

2. Low acid and alkali resistance.

1. <65℃

2. Neutral strong abrasion resistance medium

Hard Rubber

1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

2 Avoid strong oxidants

1. <80℃

2. General acid, alkali, salt solution

PFA

1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

2. High material strength, resistance to aging, better than PTFE, EFP in high temperature 

3. Injection molding for higher negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

FEP(F46)

1. Hydrophobicity and non-viscous

2. Corrosion resistance is inferior to PFA

3. Negative pressure

1. 40~180℃

2. Strong corrosion medium, like strong acid and alkali

3. Healthcare mdium

 

4. Selection of Electrode Materials

Electrode Material Main Performance
316L Good corrosion resistance to nitric acid, less than 5% corrosion of sulfuric acid, acetic acid, alkaline liquid, sulfite, seawater and acetic acid under certain pressure at room temperature, and can be widely used in petrochemical urea, vinylon and so on
Hb

Good resistance to hydrochloric acid with concentration lower than boiling point and corrosion of non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

Hc Resistant to the corrosion of oxidizing acid, such as nitric acid and mixed acid. The mixture of chromic acid and sulfuric acid, oxidized salts, such as Fe3+, Q3+, and other oxidants, such as the mixture of hypochlorite solution and seawater at higher than normal temperature.
Ti Resistant to the corrosion of seawater, various chlorides, hypochlorite, oxidized acid (including fuming nitric acid), organic acid or alkali, but not pure reducing acid (such as sulfuric acid and hydrochloric acid). However, if the acid contains oxidants (such as nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
Ta Good corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
Pt-Ir Have good corrosion resistance of all acid, and  can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
Tungsten Carbide For pulp and sewage, good resistance to solid particle interference.

 

 

5. Dimensional Sketches

a. Dimension of Converter

                                                                      Divided Type

 

 

                                                                      Integrated Type

 

                                                                  Battery Powered Type

 

 

b. Dimension of Sensor

 

 

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

 

6. Advantages & Disadvantages

There are numerous benefits to using electromagnetic flowmeters to perform fluid flow measurements. They are generally non-invasive and have no moving parts, reducing the risk of breakdowns and the frequency of repairs. A decrease in flowmeter pressure is also usually no greater than that of an equivalent pipe length, reducing the piping costs. Some of the other major advantages provided by magnetic flowmeters include:

  • Power usage is relatively low, with electrical power requirements as low as 15 watts for some models.
  • They are mechanically obstructionless and can be equipped with abrasion-resistant liners, making them effective for measuring slurries and other erosive fluids.
  • They are capable of dealing with most kinds of acids and bases, as well as water and water-based solutions, due to lining materials that are both insulators and have corrosion resistance.
  • Relatively small amounts of electrode metals are needed for magnetic flowmeters.
  • They can measure both very low flows and very high volume flow rates, with a minimum diameter of roughly 0.125 inches and a maximum volume of up to 10 cubic feet.
  • They can usually measure multidirectional flow, either upstream or downstream.

Despite these advantages, magnetic flowmeters also present certain difficulties for flow rate measurement. These flowmeters are only effective on conductive fluids, and materials such as unmixed hydrocarbons and gases cannot be measured. However, magnetic materials themselves may also present problems, as hydrodynamic effects can alter the normal flow pattern and disturb the velocity rate enough to interfere with operations. Depending on their size and capacity, magnetic flowmeters can be relatively heavy, and those with higher corrosion and abrasion resistance can be expensive.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2019

  • Total Annual:

    $1000000-$2000000

  • Employee Number:

    >50

  • Ecer Certification:

    Site Member

Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ... Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.   Our products are widely used in various fields, including electricity, chemical ...

+ Read More

Get in touch with us

  • Reach Us
  • Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
  • No.21, Lane 697, Guangfulin Road, Songjiang District, Shanghai, China
  • https://www.industrial-flowmeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details