China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity
China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity

  1. China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity
  2. China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity
  3. China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity
  4. China IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity

IEC 60068 Electrical Appliance Tester , Programmable Temperature Humidity

  1. MOQ: 1 set
  2. Price: Negotiatable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 10 sets per month
Delivery Time 20 days
Packaging Details Plywood
Working volume 150L
Temperature range -40℃~+150℃
Humidity range 20 %RH~ 98 %RH
Brand Name HongCe
Model Number PTH-1000 (150L)
Certification Third part calibration certificate(cost additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 10 sets per month
Delivery Time 20 days Packaging Details Plywood
Working volume 150L Temperature range -40℃~+150℃
Humidity range 20 %RH~ 98 %RH Brand Name HongCe
Model Number PTH-1000 (150L) Certification Third part calibration certificate(cost additional)
Place of Origin China
High Light electrical appliance testerportable appliance testing equipment

IEC 60068 Electrical Appliance Tester Programmable Temperature Humidity Chamber Working Volume 150L

 

 

Product information

 

This test device can simulate different environment condition.So it is appropriate to test material performance,such as resist heat,resist cold,resist humidity,resist dry. It is designed and manufactured in accordance with the standard requirement of IEC 60068-2-1.1990, IEC60068-2-2.1974 and ect.

 

Technical parameters

 

1. Working volume: 150L

2. Temperature range: -40 ℃~ +150

3. Humidity range: 20 %RH~ 98 %RH

*Note: Please refer to below humidity use range chart!

 

4. Temperature and humidity control accuracy: ±0.2℃; ±2.5%RH.

* To guarantee above 2~4 performance, should be measured 30 minutes after the temperature sensing measurements is stable!

 

5. Temperature and humidity distribution uniformity: ±2℃; ±3%RH.

*Note: To guarantee below 6~11 performance, the measuring positions should be each wall’s 1/6 positions of the test zone, and should be measured 30 minutes after the temperature is stable!

 

6. Heating time: Heating from the room temperature to 150℃, the total heating time is 50 mins (under non-load state).

 

7. Cooling time: Cooling from the room temperature to -40℃, the total cooling time is 40mins (under non-load state).

 

8. Inner chamber dimensions: test area: 50×60×50cm(W×H×D).

*Note: The volume of placing samples should not exceed 2/3 of the capacity of the test zone.

 

9. Equipment installation space: at least 920×1600×870cm(W×H×D).

 

10. Test chamber door: 80 × 105 cm(W×H), total 1.

 

11. Power source: AC 1220 V 50 Hz MAX 40 A

 

Structure

 

A. Chamber structure:

SUS#304, plate thickness 1 mm.

 Insulation Material: PU Foaming, thickness 100 mm.

 

B. Cooling refrigeration cycle system:

1. Refrigeration systems:

a. R404 Refrigeration cycle system

b. R23 Refrigeration cycle system

2. Condenser: Air-cooled 

3. Expansion mode: Capillary 

4. Evaporator: Air loop mode 

 

C. Heating system:

Heater: 220 V 2 KW

 

D. Humidification system:

1. Humidifier: stainless steel heater 220 V 2. KW× 1 SET.

2. Humidity gauze sink and humidifier water supply system: automatic replenishment mode.

 

E. Automatic Control System:

1. PLC control TEMI880.

* Please refer to the controller instruction manual in the CD.

2. Temperature and humidity sensors: RTD (Dry bulb / wet bulb).

* Controlled by circuit.

 

F. Air circulation and drainage systems:

1. Loop air duct: 1 group

a. material: SUS#304 stainless steel.

b. Air blower: 1 220 V 60W × 1 SET

2. Diameter of drain pipe .

 

G. Protection system:

   Over temperature protection switch

   Water shortage protection

Electromagnetic switch and overload current protector

No fuse switch

Compressor overload protector

Control circuit protection fuse

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate... Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou HongCe Equipment Co., Ltd.
  • No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
  • https://www.iectestingequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement