China 451P Ion Chamber Survey Meter Radiation Detected Of Beta Above 1MeV & Gamma
China 451P Ion Chamber Survey Meter Radiation Detected Of Beta Above 1MeV & Gamma

  1. China 451P Ion Chamber Survey Meter Radiation Detected Of Beta Above 1MeV & Gamma

451P Ion Chamber Survey Meter Radiation Detected Of Beta Above 1MeV & Gamma

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 10 sets per month
Delivery Time 30 days
Packaging Details plywood
Radiation Detected Beta above 1MeV&gamma above 25KeV
Accuracy ±10% of reading between 10% and 100% of full-scale indication on any range,exclusive of energy response (calibration source is 137 Cs)
Measuring range 0 - 50µSv/h,0-500µSv/h, 0-5mSv/h,0-50mSv/h , 0-500mSv/h
Preheat time 1 min
Power supply 9V alkaline battery, two sections
Environmental requirements - 20° to + 70°C /0 to 100%, at + 60°C less than 1%
Brand Name HongCe
Model Number 451P
Certification Calibration certificate(cost additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 10 sets per month
Delivery Time 30 days Packaging Details plywood
Radiation Detected Beta above 1MeV&gamma above 25KeV Accuracy ±10% of reading between 10% and 100% of full-scale indication on any range,exclusive of energy response (calibration source is 137 Cs)
Measuring range 0 - 50µSv/h,0-500µSv/h, 0-5mSv/h,0-50mSv/h , 0-500mSv/h Preheat time 1 min
Power supply 9V alkaline battery, two sections Environmental requirements - 20° to + 70°C /0 to 100%, at + 60°C less than 1%
Brand Name HongCe Model Number 451P
Certification Calibration certificate(cost additional) Place of Origin China
High Light audio measurement equipmention chamber survey meter

IEC 60065:2014 clause 6.1 Ion Chamber Survey Meter

 

Introduction

 

The Model 451P Ion Chamber Survey Meter is a hand-held, pressurized, battery operated unit designed to measure gamma and x-ray radiation above 25 keV, and beta radiation above 1 MeV, using the latest CMOS and LCD technology. The 451P case is constructed of high strength ABS plastic. A gasket seals moisture out of the unit and provides a cushion for the internal components. The Model 451P readout consists of a 2 1/2 digit liquid crystal display and a 100 segment analog bargraph. The bargraph contains a zero segment and twenty groups of five segments each. A permanent scale is located on the display screen. The major divisions of the scale indicate the units corresponding to the range that the meter is measuring. Units of measurement are displayed next to the 2 1/2 digit display. LOW BAT and FREEZE will appear on the display when the instrument is operating in these modes. External controls consist of an ON/OFF button and a MODE button. The unit is auto-ranging and auto-zeroing and has an auto ON backlight. The backlight automatically comes on when the ambient light conditions fall below twilight levels. An internal factory set alarm will blink the display if the rate exceeds 5 R/hr. Two 9-volt batteries, located in the rear of the instrument, provide over 200 hours of continuous operation.

 

Features

 

1. Overrange Rate

If the instantaneous radiation rate measured by the Model 451P exceeds 5 R/h, the 'R' in 'mR/h' or the 'Sv' in 'Sv/h' displayed will blink to notify the user that a potential error in the integrated radiation value exists. The blinking will stop when the integrated value is cleared. This, however, may also clear the log data RAM.

2. Low Battery Indicator

There are about six hours of operation remaining when the LOW BATTERY indicator first becomes visible. When the LOW BATTERY indicator blinks, there is less than one hour of operation remaining.

These times are for two batteries installed and from the first occurrences of these indications. If the instrument is turned off during a low battery condition, the batteries will recover somewhat, but time of operation remaining will be less. The LCD low battery indicator is disabled during communication mode.

Be sure to use fresh batteries when calibrating this instrument.

 

WARNING

 

If chamber bias is LO, the instrument can’t measure high radiation rates accurately. Service to the instrument is required.

Verify the chamber bias is low. Turn the unit off and replace with new 9-volt batteries. Power up the unit. After the self-test, if blinking low battery reoccurs the bias is low. Refer to Section 4 Maintenance.

3. Warm-up Time

The pressured ion chamber collection potential is 105 Vdc and is derived from the 5 lithium cells. The warm-up time for an instrument that has been off 12 or more hours is about four minutes for readings less than 20 μR/h in a 10 μR/h or less background.

 

Specifications

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate... Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicate...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou HongCe Equipment Co., Ltd.
  • No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
  • https://www.iectestingequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement