Packaging Details | safety box |
Delivery Time | 20~25 working days |
Payment Terms | 100% TT in advance |
Supply Ability | 3~5 units per month |
standard | IEC 60560 Figure 8 |
size | 105 X 267 X220 W *D*H mm |
capacitor C1 | 100nF |
capacitor C2 | 68 nF to 150 nF |
induction L1 | 3 mH |
incandescent lamp P | 60 W |
Brand Name | KingPo |
Place of Origin | China |
Certification | ISO 17025 Calibration certificate |
View Detail Information
Explore similar products
100N Impact LED Light Testing Equipment IEC 60598 1 Clause 8.15.1
IEC60598 Stainless Steel Testing Equipment For Lampholder Contacts
Flexible Pipe Winding LED Light Testing Equipment For String Strength
SN100 Push And Pull Tester For Electronic Appliances Textile Lighters
Product Specification
Packaging Details | safety box | Delivery Time | 20~25 working days |
Payment Terms | 100% TT in advance | Supply Ability | 3~5 units per month |
standard | IEC 60560 Figure 8 | size | 105 X 267 X220 W *D*H mm |
capacitor C1 | 100nF | capacitor C2 | 68 nF to 150 nF |
induction L1 | 3 mH | incandescent lamp P | 60 W |
Brand Name | KingPo | Place of Origin | China |
Certification | ISO 17025 Calibration certificate | ||
High Light | IEC 60560 LED Light Testing Equipment ,100nF LED Light Testing Equipment ,60W IEC Test Equipment |
IEC 60560 Figure 8 LED Light Testing Equipment For Non-Dimmable Lamp
IEC 60560 Figure 8 test equipment
IEC62560-1 Figure 8 Test Circuit For Non-Dimmable Lamp At Dimmer Or Electronic Switch
1. Use
Applying non-dimmable self-ballasted lamps on a dimmer or an electronic switch is to be tested as a possible case of abnormal operation..
2. Reference standards
IEC60560-Fig8
3. Technical parameters
Internal dimension | 105 X 267 X220 W *D*H mm |
2 | potentiometer R1 |
3 | resistor R |
4 | Triac BTA16/700 |
5 | Diac DB3 |
6 | capacitor C1 = 100 nF |
7 | capacitor C2 = 68 nF to 150 nF |
8 | induction L1 = 3 mH |
9 | basic load, incandescent lamp P = 60 W |
11 | I r.m.s. Ammeter |
Ammeter input Power | AC 220V 50Hz |
4.Test procedure:
Determine R1 and S1 setting at which the maximum I r.m.s . occurs.
Test at this situation, and if the lamp passively fails within 60 min, repeat the test at 10 % lower I r.m.s . The lower I r.m.s . shall be set in the decreasing potentiometer resistance direction.
Hot Tags: iec62560 test equipment, China, manufacturers, suppliers, factory, custom, wholesale, Lock Security Test Bench, Dielectric Strength Test Instrument, BS EN 13126 - 5 Figure A.2 Jointed Test Finger, Lamp Foot Twist Apparatus-600x600-0.jpg, Scratched Pin Electric Safety Testing Probes, IEC60529 IPX1 To IPX8 Test System
Company Details
Business Type:
Manufacturer
Year Established:
2012
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,... Kingpo Technology Development Limited is a pioneer and leader of global safety testing equipment manufacturer.We offer one-stop service for worldwide labs from R&D,testing,production to after-sales service.We dedicate ourselves in achieving optimal production quality for our customers,...
Get in touch with us
Leave a Message, we will call you back quickly!