Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Modular ISO Clean Room , Dust Free H13 H14 Prefabricated Clean Room For Lab","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/f4\/17\/7100a2b4f59608e7fa6a1a7c6337-200x200-1\/modular_iso_clean_room_2c_dust_free_h13_h14_prefabricated_clean_room_for_lab.jpg","attrs":{"Place of Origin":"Guangdong, China","Brand Name":"ZJNF","Packaging Details":"plywood\/wooden package","Supply Ability":""}}
{"title":"Positive\/Negative Pressure Control Modular Clean Room Hepa Air Filter System","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/52\/92\/a98c71c15bdd20efb530d984832b-200x200-1\/positive_2fnegative_pressure_control_modular_clean_room_hepa_air_filter_system.jpg","attrs":{"Brand Name":"ZJNF","Model Number":"Clean Booth Room","Place of Origin":"Shenzhen","Marketing Type":"Ordinary Product"}}
{"title":"65dB Noise Clean Room Booth with Positive\/Negative Pressure Control and Laminar","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e3\/70\/6823a93fbc3dc46558e8804df339-200x200-1\/65db_noise_clean_room_booth_with_positive_2fnegative_pressure_control_and_laminar_flow_hood.jpg","attrs":{"Brand Name":"ZJNF","Model Number":"Clean Booth Room","Place of Origin":"Shenzhen","Noise_Level":"Less Than 65dB"}}
{"title":"Modular Clean Room With Ceiling Ffu Air Condition Filtration System For","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e3\/70\/6823a93fbc3dc46558e8804df339-200x200-1\/modular_clean_room_with_ceiling_ffu_air_condition_filtration_system_for_unidirectional_airflow_system_dust_free_working.jpg","attrs":{"Brand Name":"ZJNF","Place of Origin":"China","Minimum Order Quantity":"1","Price":"negotiate"}}
{"title":"Modular Clean Room with Aerospace Assembly and High Air Exchange Rates using","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/fb\/7b\/6f12c4aad4ba6e5efd79196454fc-200x200-1\/modular_clean_room_with_aerospace_assembly_and_high_air_exchange_rates_using_cold_roll_steel_2fstainless_steel_body_material.jpg","attrs":{"Brand Name":"ZJNF","Place of Origin":"China","Payment Terms":"tt lc PayPal credit card","Minimum Order Quantity":"1"}}
{"title":"Modular Clean Room Manufacturers With 99.99% Filter Efficiency And High Air","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/11\/0d\/08dac0174666d85bdb8dabe77b6b-200x200-1\/modular_clean_room_manufacturers_with_99_99_25_filter_efficiency_and_high_air_exchange_rates.jpg","attrs":{"Brand Name":"ZJNF","Place of Origin":"China","Payment Terms":"tt lc PayPal credit card","Minimum Order Quantity":"1"}}
{"title":"Prefabricated Clean Environment Shelter With Advanced Air Purification And","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/11\/0d\/08dac0174666d85bdb8dabe77b6b-200x200-1\/prefabricated_clean_environment_shelter_with_advanced_air_purification_and_positive_air_pressure.jpg","attrs":{"Brand Name":"ZJNF","Place of Origin":"China","Payment Terms":"tt lc PayPal credit card","Minimum Order Quantity":"1"}}
Customized Clean Room Easy Installation dust free H13 H14 ISO Standard Modular for Laboratory with Hepa FFU fan
Clean room design
A cleanroom is a controlled environment designed to minimize the presence of airborne particles, contaminants, and pollutants, while also maintaining specific levels of temperature, humidity, and airflow. Cleanrooms are commonly used in industries where the presence of even minute amounts of contaminants can affect the quality of products or processes, or where precise and sterile conditions are critical.
Airflow → primary effect air treatment → air conditioning → medium effect air treatment → fan pressurized air supply → purified air supply pipeline →Efficient air supply outlet→ clean room → take away dust (bacteria) → return air duct → fresh air and primary air treatment.
The above proces is repeated to achieve that purpose of purification.
1. Controlled Air Quality
Particle Control: Clean rooms are designed to limit particulate contamination to very low levels. The concentration of particles in the air is carefully monitored and controlled, often classified by the number of particles per cubic meter of air at specific particle sizes.
Air Filtration: High-efficiency filters, such as HEPA (High-Efficiency Particulate Air) or ULPA (Ultra-Low Penetration Air) filters, are used to remove particles from the air. The air in a clean room is often recirculated through these filters multiple times.
2. Airflow Design
Positive Pressure: Clean rooms are often maintained at a positive pressure relative to surrounding areas. This ensures that any air that leaks out is filtered, preventing contaminants from entering the room.
Laminar or Turbulent Flow: The airflow in clean rooms may be laminar (smooth and unidirectional) or turbulent, depending on the class of clean room. Laminar flow helps to direct particles away from the work area and is typically used in high-class clean rooms.
3. Temperature and Humidity Control
Temperature Stability: Temperature is often maintained within a specific range to ensure the proper functioning of sensitive equipment and to prevent static electricity build-up.
Humidity Control: Humidity is also regulated to prevent static buildup, reduce the risk of certain contaminants, and ensure material stability.
4. Strict Protocols for Personnel
Gowning Procedures: Personnel entering a clean room must follow strict gowning protocols, such as wearing coveralls, gloves, masks, hair covers, and shoe covers to prevent contaminants from being brought in.
Access Control: Entry to the clean room is often restricted and monitored, with only trained personnel allowed to enter.
5. Clean Room Classifications
Clean rooms are classified based on the number and size of particles allowed in the air. The most common standards for classification are the ISO 14644-1 (international standard for clean rooms) and Federal Standard 209E (outdated but still referenced in some regions).
ISO Classifications range from ISO 1 (the cleanest) to ISO 9 (the least clean). For instance, an ISO 1 clean room has fewer than 12 particles per cubic meter of air, while an ISO 9 clean room allows up to 35,200,000 particles.
6. Surface Cleanliness
Smooth, Non-porous Surfaces: Surfaces inside a clean room are typically made from smooth, non-porous materials like stainless steel or epoxy-coated surfaces, which are easier to clean and less likely to harbor contaminants.
Frequent Cleaning: Clean rooms are regularly cleaned using specific cleaning agents that do not leave residues, and all items entering the room are often sterilized or sanitized.
7. Monitoring and Documentation
Continuous Monitoring: Clean rooms are equipped with sensors to monitor particle counts, airflow, temperature, and humidity. These readings are often logged continuously and checked against standards to ensure the room’s performance.
Environmental Control Systems: Advanced monitoring systems can also track air quality, contamination sources, and any deviations from standard protocols to ensure compliance with stringent requirements.
8. Materials and Equipment
Contaminant-Free Tools: Equipment and tools in a clean room are also controlled for cleanliness, often cleaned or sterilized before use. Materials used in the room, such as packaging and containers, are also often subjected to cleaning or sterilization processes to avoid contamination.
Technical Data
Cleanliness Level
Maximum Allowable Dust Number/Cubic Meter
Maximum Allowable Number of Microorganism
/
≥0.5um
≥5um
Airborne Microbe/Cubic Meter
Settling Microbe Number/Vessel·30min
100
3500
0
5
1
10000
350000
2000
100
3
100000
3500000
20000
500
10
300000
10500000
60000
/
15
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2003
Total Annual:
3000000-4000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003.
Which is the only high-tech technology company in Southern China with CNAS certification
We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ... Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003.
Which is the only high-tech technology company in Southern China with CNAS certification
We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ...
9th Floor, Block C, Coolpad Building, Intersection Of Keyuan Avenue And Baoshen Road, Nanshan Gaoxin North District, Songpingshan Community, Xili Street, Shenzhen city, Guangdong, China