Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"380AC 1.5kw Motor Large Paddle Extra Large Giant Ceiling Fans","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/34\/bf\/d6a03def73d932a7c170baa51ab8-200x200-1\/380ac_1_5kw_motor_large_paddle_extra_large_giant_ceiling_fans.jpg","attrs":{"Payment Terms":"L\/C, T\/T, Money Gram","Place of Origin":"China","Brand Name":"daisen","Certification":"ISO"}}
{"title":"China Traditional Hvls Electric Ceiling Fan With 6 Aluminum Blades","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/89\/20\/eb8f91e93b6002ba308032ed79da-200x200-1\/china_traditional_hvls_electric_ceiling_fan_with_6_aluminum_blades.jpg","attrs":{"Brand Name":"DAISEN","Model Number":"DS\/DX","Certification":"RoHS, ISO, UL, CE, SGS","Place of Origin":"Chengdu,China"}}
Big Hvls Energy Saving Industrial Pmsm Ceiling Fan Exhaust Large Fan for Air Cooling and Ventilation in
Product Description
HVLS INDUSTRIAL CEILING FANS
DAISEN PRODUCT SERIES AS BELOW:
Series
Model
Numbers of the blades
Voltage
Power
Diameter
Drive mode
Max speed
Max air volume
Max coverage area(m²)
Fit for installation height(m)
Noise level
Net weight
DS (Gearbox motor)
DS-7.3
6
220V/380V
1.5KW
7.3M (24FT)
Gearbox motor drive
50RPM
888000m3/h
1200
7~18
≤60db
156kg
DS-6.7
6
220V/380V
1.5KW
6.7M (22FT)
Gearbox motor drive
52RPM
822000m3/h
1000
6~15
≤60db
152kg
DS-6.1
6
220V/380V
1.5KW
6.1M (20FT)
Gearbox motor drive
55RPM
774000m3/h
800
6~13
≤60db
147kg
DS-5.5
6
220V/380V
1.5KW
5.5M (18FT)
Gearbox motor drive
60RPM
732000m3/h
600
5~11
≤60db
143kg
DS-5.0
6
220V/380V
1.5KW
5.0M (16FT)
Gearbox motor drive
65RPM
690000m3/h
450
5~9
≤60db
140kg
DX (PMSM motor)
DX-7.3
6
220V
1.5KW
7.3M (24FT)
brushless direct drive
50RPM
888000m3/h
1200
7~18
≤38db
106kg
DX-6.7
6
220V
1.2KW
6.7M (22FT)
brushless direct drive
55RPM
822000m3/h
1000
6~15
≤38db
100kg
DX-6.1
6
220V
1.0KW
6.1M (20FT)
brushless direct drive
60RPM
774000m3/h
800
6~13
≤38db
94kg
DX-5.5
6
220V
0.75KW
5.5M (18FT)
brushless direct drive
65RPM
732000m3/h
600
5~11
≤38db
72kg
DX-5.0
6
220V
0.7KW
5.0M (16FT)
brushless direct drive
68RPM
690000m3/h
450
5~9
≤38db
68kg
DX-4.2
5
220V
0.6KW
4.2M (14FT)
brushless direct drive
75RPM
636000m3/h
300
4~7
≤38db
64kg
DX-3.6
5
220V
0.3KW
3.6M (12FT)
brushless direct drive
90RPM
393600m3/h
250
4~6
≤45db
42kg
DX-3.0
5
220V
0.2KW
3.0M (10FT)
brushless direct drive
100RPM
331800m3/h
200
4~5
≤45db
38kg
DX-2.4
5
220V
0.15KW
2.4M (8FT)
brushless direct drive
100RPM
273000m3/h
200
4~5
≤45db
34kg
DETAILS OF CEILING FAN
DX Large ceiling fan Air volume up to 774000m³/h, fan diameter 6.0m, 6 fan blades, 6063T6, operating speed 5-65RPM (controlled by stepless inverter), net weight 82kg, wind speed 1-4m/s; coverage area up to 800m3 (10m installation height). The rated power is 1.0KW, and the noise value is less than 38dB.
EC Motor(PMSM motor)
Poleless speed control box, German Weitu structure design, bult-in MOBK frequency controller,speed control display panel, France Schneider air switch over-current overload protection, control box cooling fan assembly, fan status indicator lamp, fan status detection, accidental automatic power cut-off,anti-electromagnetic interference
Poleless speed control box Infinite speed control box, German Rittal structural design, built-in MOBK frequency controller, speed control display panel, French Schneider air switch overcurrent and overload protection, control box cooling fan assembly, fan status indicator, fan status detection, accidental automatic power off , anti-electromagnetic interference
blade
The blade is made of aeronautic Al-mg alloy material that passed T6 heat treatment process,it has high strength,highdurability,the cross section of the blade is propeller streamlined to ensure the best energy efficiency ratio. It is easy to clean after surface grinding and extremely oxidation treatment. It has low wind resistance and high efficiency,There are two reinforced tendons and over-reinforcing structure.the thinnest part is 2mm,and the thickest part is 5mm,so as to avoid fatigue loss of the blade.
Installation kits
Our company's unique design of row holes on the installation plate, can prevent the sliding of the installation plate, we also have installation kits for concrete and and circular tube structure as well as any other kinds of structure.
Steel rope
8mm diameter steel rope wrapped with anti-rust plastic,reinforced rope clip,with anti-skip turnbuckle screw tension and adjust the horizon of the fan, prevents shaking of the fan, absorb the vibration energy.
Comparison of three refrigeration methods in 1000 square meter plant
Refrigeration mode
Quantity
Power/unit
Tall power
General comparison
Central air conditioner
1
80KW
80KW
The walls and doors and windows of the plant are required to be insulated. The cost of one-time investment of the equipment is high, and the maintenance cost of replacing the filter element and adding refrigerant is high
Traditional industrial fan
40
0.3KW
12KW
The installation of traditional wall fans is limited by walls and columns. The power lines of floor fans are scattered, which has potential safety hazards. It is not safe for the hair of staff members to be mixed into the fan blades, which occupies a small space and covers a short service life
7.3M HLVS industrial ceiling fan
1
1.5KW
1.5KW
Large coverage area, long service life, low maintenance cost, installation does not occupy the workshop space, safety and environmental protection
The energy consumption of large industrial ceiling fan is about 1 / 50 of that of central air conditioner and 1 / 10 of that of traditional industrial wall fan
application space of product
The technology of industrial large fans originated from the United States, and it is the most direct and effective solution to the problem of ventilation and cooling in tall spaces. Localization has been widely used in various industries. At present, DAISEN industrial large fans are widely used in: 4-20m high processing plants, warehousing and logistics, indoor sports stadiums, gyms, station shopping malls, breeding and other places.
According to the demands of customers, DAISEN independently developed, designed and manufactured power and fluid mechanical fan blades through researching the market, which can provide a large area of the wind speed that simulates natural wind, drive air circulation in a closed room, effectively improve human body sensation and comfort, and operate smooth and reliable. DAISEN HVLS ceiling fans have a wider range of applications, lower prices, and can meet customer needs from multiple angles.
What are you looking for? Come and order!
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2017
Total Annual:
2000000-3000000
Employee Number:
35~50
Ecer Certification:
Verified Supplier
Sichuan Junyi Industrial Equipment Co.,ltd,focuses on the ventilation and Ventilation Research of tall and large buildings. It has a product R & D team with strong technical force and a rigorous marketing team.
In the process of rapid development, the company always ad...
Sichuan Junyi Industrial Equipment Co.,ltd,focuses on the ventilation and Ventilation Research of tall and large buildings. It has a product R & D team with strong technical force and a rigorous marketing team.
In the process of rapid development, the company always ad...
No.5, building 11, Juneng international industrial port, No.117, Nansan Road, economic development zone, Longquanyi District, Chengdu, Sichuan Province, China