Payment Terms | T/T, Paypal, Western Union |
Supply Ability | 500pcs per month |
Delivery Time | 1-4days |
Packaging Details | Standard export package |
Material | ABS |
Application | Measurement of light sources and irradiation systems, transmission measurements, UV radiation safety |
Illumination measurement range | (0.1 ~ 199.9×103) lx |
Ultraviolet wavelength range and peak wavelength | lambda P (315 ~ 400) nm, lambda P = 365nm |
The irradiance measurement range | muw /cm2 (0.1 ~ 199.9×103) |
Long wave response error | <15% |
Size and weight | 180mm×80mm×36mm;0.2kg |
Power | 9V battery(6F22)1pc |
Product name | Black Light Meter And Visible White Light Meter |
Brand Name | HUATEC |
Model Number | LX1500 |
Certification | ISO, CE, GOST |
Place of Origin | Beijing |
View Detail Information
Explore similar products
20-0-20 Gs Pocket Magnetic Strength Meter Gauss Meter Magnetic Filed Indicator
Portable MT Flaw Detector Magnetic Particle For Aviation
110V Crack Testing Equipment Magnetic Particle Testing For Surface Crack Testing
UV Radiometer UV-A Ultraviolet Irradiance Meter UV Light, Ultraviolet Illuminome
Product Specification
Payment Terms | T/T, Paypal, Western Union | Supply Ability | 500pcs per month |
Delivery Time | 1-4days | Packaging Details | Standard export package |
Material | ABS | Application | Measurement of light sources and irradiation systems, transmission measurements, UV radiation safety |
Illumination measurement range | (0.1 ~ 199.9×103) lx | Ultraviolet wavelength range and peak wavelength | lambda P (315 ~ 400) nm, lambda P = 365nm |
The irradiance measurement range | muw /cm2 (0.1 ~ 199.9×103) | Long wave response error | <15% |
Size and weight | 180mm×80mm×36mm;0.2kg | Power | 9V battery(6F22)1pc |
Product name | Black Light Meter And Visible White Light Meter | Brand Name | HUATEC |
Model Number | LX1500 | Certification | ISO, CE, GOST |
Place of Origin | Beijing | ||
High Light | 365nm illuminance meter ,420um illuminance meter ,abs illuminance meter |
365nm And 420um UV Black Light Meter And Visible White Light Meter Illuminance Meter LX1500
Aplplication: Measuremen of light sources and irradiation systems, transmission measurements, UV radiation safety.
The instrument apply to different ultraviolet irradiation measurement field, such as photochemical, polymer materials aging, flaw detection, UV light source, plant cultivation and large scale integrated circuit
Product overview
Ultraviolet/visible (radial) illuminance meter adopts SMT patch technology, adopts high precision and low power consumption digital chip, the instrument shell is streamlined design, the detector after strict spectrum and Angle characteristics correction, stable performance, strong applicability. The instrument integrates two functions of ultraviolet irradiance measurement and illumination measurement, and is widely used in various fields such as photochemistry, polymer material aging, flaw detection, ultraviolet light source, plant cultivation, large-scale integrated circuit industry, agriculture, architecture, environment and scientific research.
Product features
Spectral and angular characteristics are strictly corrected
Digital liquid crystal display with backlight
Manual/automatic range switching
Digital output interface (USB, redundant power supply)
Low battery alert
Automatic delay shutdown
Number holding
Tap the button to operate, beeping prompt
Specifications
Illumination measurement range: (0.1 ~ 199.9×103) lx
Relative indication error: <± 4.0%
V (lambda) matching error: less than 6.0%
Cosine characteristic error: < 4.0%
Response time: <1 second
Ultraviolet wavelength range and peak wavelength: lambda P (315 ~ 400) nm, lambda P = 365nm
The irradiance measurement range: muw /cm2 (0.1 ~ 199.9×103)
Long wave response error: <15%
Relative indication error: <± 8% (relative to NIM standard)
Nonlinear error: <± 1.5%
Response time: <1 second
Zero value error: (full range FS) < ±1.0% of full range
Shift error: <±1.0%
Fatigue error: <3.0%
Ambient temperature: (0~40)℃; Humidity < 85% RH
Size and weight: 160mm×78mm×43mm; 0.2 kg
Power supply: 6F22 9V laminated battery (non-rechargeable battery)
Overall power consumption: < 0.1va
Maintain
Please store the instrument in a clean environment, temperature (0~40)℃ and humidity <85%RH to avoid any damage.
Warranty
We can repair or change it during one year freely if there is any problems which is not caused by improper use and maintain.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2010
Total Annual:
600-1000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Established in year 2000,HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to ... Established in year 2000,HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to ...
Get in touch with us
Leave a Message, we will call you back quickly!