Delivery Time | 5-6weeks after deposit |
Packaging Details | standard for export |
Color | Gray (Ral 7035 |
input | 220/230 single phase or 3phase 380/400/480Vac |
Input with TX | Input isolation transformer |
input range | 220/230+15%;3phase 380/400/480Vac+/-15% |
Input Fz | 45-66Hz |
Ouput DCv | 24,48.60,110,125,110,220Vdc |
IP degree | IP21-IP43 |
Cable Entry | bottom |
Operation Temperature | 0-40centigrade |
Capacity | 2.4kw to 220kW |
Brand Name | HRD/OEM |
Model Number | R7000 |
Certification | CE |
Place of Origin | Shenzhen China |
View Detail Information
Explore similar products
AC/DC Industrial rectifier With Input Isolation Transformer
24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer
Product Specification
Delivery Time | 5-6weeks after deposit | Packaging Details | standard for export |
Color | Gray (Ral 7035 | input | 220/230 single phase or 3phase 380/400/480Vac |
Input with TX | Input isolation transformer | input range | 220/230+15%;3phase 380/400/480Vac+/-15% |
Input Fz | 45-66Hz | Ouput DCv | 24,48.60,110,125,110,220Vdc |
IP degree | IP21-IP43 | Cable Entry | bottom |
Operation Temperature | 0-40centigrade | Capacity | 2.4kw to 220kW |
Brand Name | HRD/OEM | Model Number | R7000 |
Certification | CE | Place of Origin | Shenzhen China |
High Light | scr ac dc rectifier ,2.4kw ac dc rectifier ,220kw industrial rectifier |
R7000 Series Industrial Charger & DC UPS, With Input Isolation Transformer, 24VDC,48VDC, 110VDC,125VDC,220VDC
Introduction:R7000 series 2.4kw to 500kW industrial rectifier is specially designed for harsh industrial application environment with high performance application requirements. It provides super high reliability, high performance and high quality DC power.
R7000 industrial rectifier is designed on thyristor technology, the rectifier can charge nickel cadmium battery , lead-acid battery etc. and supply DC load at the same time. It can also be used as independent DC power supply without battery.
Perfect Applications:
P e t r o l e u m , petrochemical, power plant, natural gas, electric power, marine, heavy industry, mining, transportation and other industry field .
Features and benefits:
1)SCR rectifier with DSP control technology, overvoltage,undervoltage protection for reliable operation in all mains conditions
2)Input isolation transformer for AC- DC
3)High operating safety and reliability, even under difficultcircumstances over long periods of time
4) Adjustable manual and automatic charging mode for maximum flexibility on operation
5)Digital control panel and touch screen for meters, alarms,and history events for maximum flexibility on monitoring
6) Advanced intellegent Parallel operation for redundancy requirements,up to 8 units!
7) Support all charging mode for vented/sealed lead acid batteries and Ni- Cd batteries
8)More than 12,000 history records to position issues quickly and accurately
9) Front accessibility for easy maintenance
10)Battery charging temperature compensation
11) Cable voltage drop compensation
Technicaldata:
Input | Rated voltage | 230Vac 1phase or 400Vac 3phase | |||
Voltage range | 230Vac+/-15% or 400Vac+/-15% | ||||
Frequency range | 45-66Hz | ||||
Output | Rated voltage | 24,48,60,110,125,220Vdc | |||
Operating Voltage | Floating:75%-125% of rated voltage at full load and rated voltage+/-10% Equalizing:75%-125% of rated voltage at full load and rated supply voltage(0-10%) Commissioning:75%-140% of rated voltage at half load and rated supply voltage(0-10%) | ||||
Static voltage regulation | +/-0.5% | ||||
Ripple Voltage | ≤1% | ||||
Charging characteristic | IU( according to DIN41773) | ||||
System and Environmental | Protection degree | IP21(Optional to IP43) | |||
Cable entry | bottom | ||||
access | front | ||||
Color | RAL7035 | ||||
Operation temperature | 0-40 centigrade | ||||
Storage temperature | -25-70centigrade | ||||
Noise | <65dBA | ||||
Altitude | <1000m(derating according to EN62040-3) | ||||
Cooling | Forced Ventilation | ||||
Standard | Safe | IEC60146 | |||
EMC | IEC61000-6-2 IEC61000-6-4 | ||||
Performance | IEC601146 | ||||
Communication | RS-232/485,Modbus Protocal | ||||
Rating | Rated Voltage(Vdc) | 24 | 48/60 | 110/125 | 220 |
Rated Current(A) | 25 | 25 | 25 | 25 | |
50 | 50 | 50 | 50 | ||
75 | 75 | 75 | 75 | ||
100 | 100 | 100 | 100 | ||
150 | 150 | 150 | 150 | ||
200 | 200 | 200 | 200 | ||
300 | 300 | 300 | 300 | ||
400 | 400 | 400 | 400 | ||
500 | 500 | 500 | 500 | ||
600 | 600 | 600 | 600 | ||
800 | 800 | 800 | 800 | ||
1000 | 1000 | 1000 | 1000 | ||
2000 | 2000 | 2000 | 2000 | ||
3000 | 3000 | 3000 | / | ||
4000 | 4000 | 4000 | / |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
15,000,000-200,00,000
Employee Number:
300~500
Ecer Certification:
Verified Supplier
About HRD ,founded in 2010, after more than 14 years fast development,HRD has grown into a large leading professional UPS manufacturer with ISO9001:2015 , ISO14001,ISO18001 certified Based on strong high level professional R&D team with... About HRD ,founded in 2010, after more than 14 years fast development,HRD has grown into a large leading professional UPS manufacturer with ISO9001:2015 , ISO14001,ISO18001 certified Based on strong high level professional R&D team with...
Get in touch with us
Leave a Message, we will call you back quickly!