Payment Terms | T/T, L/C, Western Union |
Supply Ability | USD1000/SET |
Delivery Time | 10-15days |
Packaging Details | Nude packing,Package with Steel Box,or Wooden Box |
Type | DZL/DZH |
Pressure | Low Pressure |
Installation | Assembled Boiler |
Drum | Single drum type |
Burner | Riello, Baltur,or Optional |
Usage | Industrial |
Manufacturing Level | A |
Name | Coal boiler with hopper |
Brand Name | YONGXING |
Model Number | DZL/SZL |
Certification | ISO9001,ISO14001,SGS,BV |
Place of Origin | HENAN |
View Detail Information
Explore similar products
Steel Q345R Material Coal Fired Steam Boiler In Textile Industry 4 Ton Chain
Large Stove Sawdust Fired Boilers / Wood Pellet Fired Steam Boiler 6000Kg Steam
Industrial Steam Generator Furnace Q345R Steel Plate Material Furnace High
8 Ton Coal Fired Steam Boiler With Energy Saving Light Chain Grate ISO9001
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | USD1000/SET |
Delivery Time | 10-15days | Packaging Details | Nude packing,Package with Steel Box,or Wooden Box |
Type | DZL/DZH | Pressure | Low Pressure |
Installation | Assembled Boiler | Drum | Single drum type |
Burner | Riello, Baltur,or Optional | Usage | Industrial |
Manufacturing Level | A | Name | Coal boiler with hopper |
Brand Name | YONGXING | Model Number | DZL/SZL |
Certification | ISO9001,ISO14001,SGS,BV | Place of Origin | HENAN |
High Light | coal fired water tube boiler ,coal fired central heating boilers |
Dzl Type Different Pressure Coal Fired Boiler with Travelling Chain Grate for Vietnam Paper Factory
Advantages
1.Low original dust concentration. Efficient and energy-saving enhanced combustion technology, and designed with large volume furnace and combustion chamber.
2. Sufficient power output. The middle partition wall structure is conducive to fly ash burning, increase the flue gas stroke, and increase the heat transfer in the combustion chamber.
3. Feature layout refresh energy efficiency. Advanced threaded pipe structure, high heat transfer coefficient, low heat loss, and much higher efficiency than similar products.
4. Conquer the drum kit problem. Part of the riser on the two sides of the header is pulled toward the furnace, and the novel furnace structure avoids the "bullet" defect.
5. Rapid warming. A large number of efficient heat transfer thread pipe is placed in the shell, and the heating time is about 1/3 shorter than that of the water tube boiler.
6. Tube sheet is reliable and durable. The use of arched tube sheets and the addition of partitions will improve the water circulation here and allow the front tube sheets to be adequately cooled.
7. Low investment in boiler room. In the same capacity furnace type, the smallest size, the boiler room investment is reduced by at least 1/3 and the old boiler room is suitable for reconstruction and expansion.
8. Power failure self-protection. The natural circulation makes the water wall not vaporized, and it is possible to prevent damage accidents without special protection measures.
Technical data sheet 1
Auxiliary System | Parts |
Water supply system | soft water, demineralized water system, deaerator, feed water pump, water tank, ammonia adding device, dosing device |
Steam (hot water) system | Steam separator (water) cylinder, desuperheater |
Fuel supply system | Coal machine, belt coal conveyor, crusher, vibrating screen electronic belt scale, electromagnetic iron remover, double pear type unloader, pre-furnace coal feeder, etc |
Smoke system | Blower, induced draft fan, chimney, etc. Sewage (steam) system, row, row, sampler, silencer |
Electronic control system | General control, PLC control, DCS control |
Other equipment in the boiler room | Heat exchange station, circulation pump, decontamination unit, etc. |
Flue gas purification system | Dust collector, desulfurization device, denitration device, etc. |
Technical data sheet 2
Item No. | DZH0.5-0.7 | DZH1-1.0 | DZH1-1.25 | DZH2-1.0 | DZH2-1.25 | DZH4-1.25 | DZH4-1.6 | DZH6-1.25 |
Rated steam output(t/h) | 0.5 | 1 | 1 | 2 | 2 | 4 | 4 | 6 |
Rated work pressure(Mpa) | 0.7 | 1 | 1.25 | 1 | 1.25 | 1.25 | 1.6 | 1.25 |
Rated steam temperature(°C) | 165.3 | 184 | 194 | 184 | 194 | 194 | 204 | 194 |
Rated feed water temperature(°C) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Thermal efficiency(%) | 76.6 | 77.18 | 77.6 | 76.8 | 77.7 | 78.8 | 78.8 | 78.5 |
Fuel consumption (kg/h) | 79 | 172 | 178 | 358 | 361 | 726 | 732 | 1080 |
Shipping size(m) | 3.67* 1.76* 2.78 | 4.31* 1.9* 2.86 | 4.31 *1.9* 2.85 | 5.41 *2.6* 3.1 | 5.41 *2.6* 3.26 | 5.86 *2.8* 3.39 | 5.86 *2.8* 3.4 | 6.2* 2.96* 3.58 |
Quckly installed boiler | |||||
boiler model | Unit | DZL1-0.7/1.0-AII | DZL2-0.7/1.0-AII | DZL4-0.7/1.25/1.6-AII | DZL6-1.25/1.6-AII |
capacity | ton/h | 1 | 2 | 4 | 6 |
rated pressure | Mpa | 0.7/1.0 | 0.7/1.0 | 0.7/1.25/1.6 | 1.25/1.6 |
rated steam temeperature | ℃ | 170/184 | 170/184 | 184/193/204 | 193/204 |
feed water temperature | ℃ | 20 | 20 | 20 | 105 |
radiation area | ㎡ | 4.21 | 6.43 | 10.55 | 16.95 |
convection area | ㎡ | 20.68 | 39.23 | 90.45 | 134.87 |
economizer area | ㎡ | 9.66 | 16.56 | 16.56 | 53.13 |
valid grate area | ㎡ | 1.852 | 3.15 | 5.18 | 8.395 |
applicable fuel | * | COAL | COAL | COAL | COAL |
exhaust gas temperature | ℃ | 152/160 | 152/161 | 163/163.8/169.5 | 163/169 |
design efficiency | % | 77.73/77.24 | 78.53/78.18 | 79.37/79.30/78.96 | 79.83/79.19 |
fuel consumption | kg/h | 170.74/172.93 | 341.71/343.63 | 673.22/676.27/682.11 | 866.39/877.51 |
max part size for delivery | mm | 5488*2254*2782 | 5694*2704*3324 | 6743*2954*3508 | 8244*2951*3704 |
TWO PART ASSEMBLED BOILER | ||||||||
boiler model | Unit | SZL6-1.25/1.6-AII | SZL8-1.25/1.6-AII | SZL10-1.25/1.6-AII | SZL12-1.25/1.6-AII | SZL15-1.25/1.6-AII | SZL20-1.25/1.6-AII | SZL25-1.25/1.6-AII |
capacity | ton/h | 6 | 8 | 10 | 12 | 15 | 20 | 25 |
rated pressure | Mpa | 12.5/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
rated steam temeperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
feed water temperature | ℃ | 105 | 105 | 105 | 105 | 105 | 105 | 105 |
radiation area | m2 | 18.19 | 22.14 | 25.8 | 25.8 | 34.117 | 53.78 | 99.21 |
convection area | m2 | 121.9 | 158.86 | 200.38 | 250.17 | 331.616 | 411.8 | 457.78 |
economizer area | m2 | 53.13 | 104.64 | 130.8 | 174.4/261.1 | 117.72/117.2 | 212.4 | 476.16 |
valid grate area | m2 | 7.55 | 9.34 | 10.98 | 12.78 | 16.24 | 20.84 | 24.76 |
applicable fuel | COAL | COAL | COAL | COAL | COAL | COAL | COAL | |
exhaust gas temperature | ℃ | 165.78/169.85 | 161/165 | 160/162 | 158/150 | 156.7/159.4 | 153/159 | 152/156 |
design efficiency | % | 80.11/79.44 | 79.95/79.98 | 80.55/80.28 | 80.68/80.72 | 80.48/80.56 | 81.09/80.77 | 81.38/81.26 |
fuel consumption | kg/h | 863.28/874.78 | 1153.42/1161.38 | 1430.96/1442.74 | 1714.5/1721.8 | 2167.89/2164.7 | 2868.63/2884.7 | 3551/3556 |
max part size for delivery | mm | 7100*2800*3500 7300*2540*2330 | 7300*3000*3500 7400*2700*2330 | 7600*3200*3500 7700*2900*2330 | 7600*3200*3500 8500*2900*2330 | 7350*3373*3505 8904*3370*1100 | 7814.7*3573*3511 9439*3768*1100 | 8478*2600*2740 Bulk packing |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company,Seller
Year Established:
2000
Total Annual:
100-500
Employee Number:
500~1000
Ecer Certification:
Active Member
Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil... Yongxing Boiler Group Co., Ltd. is a group company specializing in research, development, manufacturing, sales and installation services for various boilers and various thermal energy machinery and equipment. Yongxing Boiler occupies an area of 60,000m2, with fixed assets of 15 mil...
Get in touch with us