China factories

China factory - Beijing HiYi Technology Co., Ltd

Beijing HiYi Technology Co., Ltd

  • China,Beijing ,Beijing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Handheld Exhaust Gas Analyzer Diesel Smoke Level Testing Portable Automobile
China Handheld Exhaust Gas Analyzer Diesel Smoke Level Testing Portable Automobile

  1. China Handheld Exhaust Gas Analyzer Diesel Smoke Level Testing Portable Automobile
  2. China Handheld Exhaust Gas Analyzer Diesel Smoke Level Testing Portable Automobile

Handheld Exhaust Gas Analyzer Diesel Smoke Level Testing Portable Automobile

  1. MOQ: 1
  2. Price: $1000-3000/set
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 10000 set/month
Delivery Time 3-7 days
Packaging Details plastic case
Name Opaque Smoke Meter
Display 7 inch high brightness LCD display
Temperature Temperature: -5~40℃
Humidity ≤95% RH
Pressure 70~106 kps
Measurement range Dark lighting N 0-99.9%
Optical absorption coefficient K 0-16.00m-1
Brand Name HiYi
Model Number 5Y
Certification CEE/RoHS
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 10000 set/month
Delivery Time 3-7 days Packaging Details plastic case
Name Opaque Smoke Meter Display 7 inch high brightness LCD display
Temperature Temperature: -5~40℃ Humidity ≤95% RH
Pressure 70~106 kps Measurement range Dark lighting N 0-99.9%
Optical absorption coefficient K 0-16.00m-1 Brand Name HiYi
Model Number 5Y Certification CEE/RoHS
Place of Origin China
High Light Handheld Exhaust Gas AnalyzerDiesel Exhaust Gas AnalyzerPortable Exhaust Gas Analyzer
Diesel Smoke Level Testing Opaque Portable Automobile Smoke Meter LCD Display Handheld Exhaust Gas Analyzer
5Y Opaque Smoke Meter
OVERVIEW

The measurement unit of 5Y opaque smoke meter adopts shunt technology to measure the smoke emission of diesel engine. Air curtain technology is used to protect optical system from pollution.

 

SPECIFICATION
Warm up time
10 minutes
Size
Control unit: 610*500*330 mm
Test unit: 500*300*33 0mm
Weight
Control unit: 6kg (include printer)
Test unit: 13.5Kg
Power supply
AC220V ±10%; 50Hz ±1Hz
Environment conditions
Temperature: -5~40℃
Humidity: ≤95%
Pressure: 70~106 kps
Measurement range
Dark lighting N:0-99.9%
Optical absorption coefficient K: 0-16.00m-1
Resolution
Opacity N: 0.1%
Coefficient of light absorption K:0.01m-1
Indication Error
Opacity N: ±2.0%(absolute error)
Display
7 inch high brightness LCD display
Optional function
Gas temperature and engine speed optional configuration

 

FEATURES & BENEFITS

1.The performance of the instrument meets the requirements of GB3847-2005.

2.Fission structure,Measurement and control unit

■ Separate structure, separate measurement and control unit, easy to operate.

■ The measurement unit adopts the split-flow technology to measure the exhaust smoke of diesel vehicles. Air curtain technology is used to protect optical system from pollution. The constant temperature control of the testing room can prevent condensation and avoid the influence of temperature change on the measurement accuracy.
■ Optional function: Gas temperature and engine speed optional configuration
3.Multi test mode,convenient to use
■ It has the functions of free acceleration test and transient measurement, and can automatically process test data and display measurement results.
■ Opacity and absorption coefficient, N&K, simple operation

■ The alarm of K value exceeding the standard: When the K value exceeds the user's set value, the instrument automatically alarms.

4.Powerful standard configuration

■ Digital time display.
■ Large and high brightness LCD display
■ Support multi-language (English & Chinese)operation menu
■ Equipped with internal printer
■ Automatically Auto-zeroing
■ Have more than 500 groups of data storage and access functions
■ Equipped with RS-232C digital serial communication interface to facilitate networking
■ The input function of license plate number can input the vehicle platoon head and license plate number of provinces, municipalities and autonomous regions, which makes the vehicle and test results correspond one by one in the use of users, making it more convenient to inquire and call between departments.

APPLICATION

It's suitable for all levels of traffic, public security testing stations, environmental protection exhaust control points at all levels, teaching laboratories of colleges and universities, automobile manufacturers, engine manufacturers, motorcycle manufacturing areas, as well as the use of one, two and three types of automobile repair plants, 4S shops, automobile repair and maintenance departments. 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2001

  • Total Annual:

    10000000-15000000

  • Employee Number:

    30~50

  • Ecer Certification:

    Verified Supplier

HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan... HiYi Techonology is a professional company of committed to the development of the gas detection industry, has more than 15-year experience in specializing in the research, development, manufacture and sale of gas detectors. With the strong technical force and economic strength, company is constan...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing HiYi Technology Co., Ltd
  • Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
  • https://www.hiyipro.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement