China SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer
China SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer

  1. China SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer
  2. China SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer

SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer

  1. MOQ: 1 set
  2. Price: Factory price
  3. Get Latest Price
Packaging Details standard carton box
Delivery Time Within 1-2 working days upon received payment
Payment Terms T/T, MoneyGram, Paypal
Supply Ability 200 sets/week
Place of Origin China
Brand Name HIPPOTECH

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details standard carton box Delivery Time Within 1-2 working days upon received payment
Payment Terms T/T, MoneyGram, Paypal Supply Ability 200 sets/week
Place of Origin China Brand Name HIPPOTECH
High Light mechanical workshop equipmentworkshop tools and equipment

SV5Q Micro LCD Display Auto Workshop Equipment Exhaust Gas Analyzer

Description:

SW-5Q automobile exhaust gas analyzer, in accordance with non-light-disguising infrared absorption method, via micro-computer analysis, directly measure the thickness of HC, CO and CO2 in the exhaust gas of vehicles 

and inspect the density of NO and O2 via Electrochemical sensor so as to calculate excess air coefficient λ.

 The analyzer introduces advanced foreign technology. It is composed of complete imported machinery cores,

 boasts the advantages of accuracy measurement, high endurance and speed. As an Intelligent Equipment, 

it is equipped with Microprocessor, LCD and Chinese language interface. Besides, it also has optional 

equipments such as Induction Tachometer, temperature sensor, inner Micro Printer for customers to purchase.

 The newly-added Storage function can detect Engine's speed and Lubricant's Temperature while measuring

 tail gas, then store and print the results.


Besides detecting functions, its computer programs on detection under Two-speed Idle, written by us

 according to limits and measurement methods for exhaust pollutants from vehicles equipped ignition 

engine under two-speed idle conditions and simple driving mode conditions,  can control the process of 

detection automatically. So it's convenient to use. The analyzer has small size, light weight, storage of 500 

groups' data of exhaust gas measurement. Particularly it is suitable for check along the road. It's utilized for

 auto-manufacturing factories, vehicle inspection stations and garages.

The main technical parameters:

1. Environmental temperature

Temperature:-5~40℃  
humidity: ≦95%  
Air pressure: 70.0~106kPa    
Power:  AC  220V±10%;50Hz±1Hz

2.Measuremnt scope:
HC:   0~10000 10-6(ppm)vol
CO:   0~10.0      10-2(%)vol

CO2 : 0~20.0      10-2  (%)  vol
O2 :  0~25.0      10-2(%)vol 
NO:   0~5000     10-6(ppm)vol  
oil temperature:0~120℃
rotate speed:    0~10000rpm

3.Sampling method:
tail gas: sampling directly .
The length of sampling tube: 5m,the length of probe:900mm.

Oil temperature:inserting the head of thermo scope into the staff gauge of engine lubricant, the length of

 which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting: 

length of lead: 5m.

Rated rpm: Non-contact measurement method. Less than 20cm to the petrol high-voltage flexible cord,

 measuring petrol rotate speed.

 

4.preheat time:10mins

5.resolution:
CO: 0.01% vol  
HC:   1ppm vol normal hexane equivalent 
CO2: 0.01% vol  
O2 :   0.01%vol

NO:  1ppm vol  
rate speed: 1rpm  
oil temperature: 0.1℃

6.indicated error:
CO:    ±0.06% vol or±5% relative error.   
HC:    ±12ppm vol or ±5% relative error

CO2 : ±0.5% vol or ±5% relative error 
O2 :   0.1% vol or±5% relative error

NO: ±25ppm vol or±5% relative error  
rate speed:      ±10rpm(0~10000rpm) ±1% measured value      (>10000rpm)

7.Stability:after preheating, zero excursion and measurement distance excursion in 4 hours should not

 be over the allowance value of sample value error

8.Repetitiveness: ≤1/2 of absolute of the allowed sample value error

9.Output signal: Number volume: RS232 serial massage exit.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2008

  • Total Annual:

    10Million-100Million

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

AG SONIC TECHNOLOGY LIMITED. is the expert manufacturer in auto maintenance, Auto Locksmith tools,obd2 code reader,key programmer field,  we can offer you the most favorable service and also after ... AG SONIC TECHNOLOGY LIMITED. is the expert manufacturer in auto maintenance, Auto Locksmith tools,obd2 code reader,key programmer field,  we can offer you the most favorable service and also after ...

+ Read More

Get in touch with us

  • Reach Us
  • Hippo Technology Co.,LTD
  • Meilong Road,Minzhi Street, Longhua Town, Shenzhen, China
  • https://www.auto-diagnosticstools.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement