China Decoupler Series Surge Protective Device TOQ 35A 63A For AC DC System
China Decoupler Series Surge Protective Device TOQ 35A 63A For AC DC System

  1. China Decoupler Series Surge Protective Device TOQ 35A 63A For AC DC System
  2. China Decoupler Series Surge Protective Device TOQ 35A 63A For AC DC System

Decoupler Series Surge Protective Device TOQ 35A 63A For AC DC System

  1. MOQ: 1 unit
  2. Price: USD, Negotiable, unit
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 4,000,000 units/year
Delivery Time 5-7 days
Packaging Details Carton
Structure Zinc Oxide Arrester
Application AC/DC System
Inductance factor 15μ H (5μ H) ±20%
Nominal Operating Current In 35A/63A
Trademark XIWUER
Ambient Temperature -40℃~ 85℃
Brand Name Qing Zhu
Model Number TOQ 35A
Certification UL,TUV,CCC,ROHS
Place of Origin XIAN,CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 4,000,000 units/year
Delivery Time 5-7 days Packaging Details Carton
Structure Zinc Oxide Arrester Application AC/DC System
Inductance factor 15μ H (5μ H) ±20% Nominal Operating Current In 35A/63A
Trademark XIWUER Ambient Temperature -40℃~ 85℃
Brand Name Qing Zhu Model Number TOQ 35A
Certification UL,TUV,CCC,ROHS Place of Origin XIAN,CHINA
High Light Decoupler Surge Protective DeviceTOQ Surge Protective Device35A ac surge protector

Decoupler Series TOQ 35A 63A coupling device widely used in multi-level protection lines

 

Decoupler is a coupling device widely used in multi-level protection lines, and is widely used in power lines with current less than 63A in power distribution systems. When the lightning current invades the line, the installed decoupler can make the first-level SPD of the line act first, release most of the lightning wave energy, reduce the energy of the second-level SPD, so as to realize a two-level surge protector The cooperation between the two can realize the large inrush current that the system bears, the low residual voltage, and the protection of the subsequent circuits and equipment from overvoltage.

 

Features

  • It is connected in series in the low voltage operating AC power system, with AC 50Hz/60Hz, nominal voltage of 500V or less.
  • It is used to increase the inductive reactance of the wire, and make up for the deficiency of the wire length, to make sure for the good match between the lightning protectors of two classes;
  • It is used for decoupling between lightning protectors of two classes in one distribution panel;
  • Suitable for different networks: TN TT IT
  • Maintenance is unnecessary

  • Various nominal current choice

Technical Parameters

Model No. TOQ-35 TOQ-63
Nominal Operating Voltage Un 500VAC
Nominal Operating Current In 35A 63A
Inductance factor Ln 15μ H (5μ H) ±20%
DC Resistance Rcu ≤ 3 m Ω
Protective Level IP 20
Recommended Data forBackup Fuse 35AgL/gG 63AgL/gG
Installation Pattern Mounted on 35mm Standard Rail
Ambient Temperature -40℃~ 85℃
Max. Relative Humidity ≤ 95%
Dimension (W×H×D) 35(18)×65×90 35(30)×65×90

Section area of theInductance Solid Conductor/

Stranded/Stranded Soft Wire

Tightening torque atleast 4Nm

10 ~50/10 ~25/10 ~35mm2

AWG8~2

Operation and Maintenance

  • When the installation distance between the switch type surge protector and the voltage limiting type surge protector is less than 10m, or the distance between voltage limiting type surge protectors is less than 5m, decoupler shall be installed between the surge protectors to increase the inductive reactance.
  • It is connected in the power system in series. The installation is carried on by skilled electrical staff.Inspection shall be made before the installation, to check if the nominal Un value and In value match with the actual system voltage and current. It shall not be installed if not match or the appearance is damaged.
  • Pay attention to the temperature allowance when several decouplers and surge protectors are

    connected together.

  • Fix the connection screw regularly, and check the appearance of the device, replace the device immediately if any failure occurs.

 

COMPANY OVERVIEW

 

     Xian Xiwuer Electronic & Info. Co., Ltd. is located in Beiguan, Xi'an city cover in an area of 4000 , with employees of 2300, and about 580 technicians, amongthem, there are 135 engineers, 21 senior engineers. The company has total assets of 315 million RMB Yuan, fixed assets of 137 million RMB Yuan, which is a large enterprise mainly engaged in producing electronic components. The company has the largest production scale of Varistor,SPD( Surge Protective Device)and HV Ceramic Capacitor in China, with the following main products :

1. Varistors & SPD

2. HV Ceramic Capacitor
3. Capacitive Voltage Divider

4. Thermistor 

      The main production line and inspection equipment & instrument are imported from Japan, America, Belgium and Switzerland etc. The annual production capacity of the two leading products has been reached to 5 million pcs and 150 million pcs respectively, with the market holding rate in China of about 10% and 30% respectively by continually technical innovation. Varistors and SPD produced by the company enjoyed great reputation in the international market, being exported to many countries and areas such as Japan,USA, Hong Kong etc., with the customers like India and GE in USA. are already sold to LG company in Korea with large quantity, and also to Spainand India etc.

         Not only the products quality and technical capacity, but also the completeness of the models are all in the leading place in China. The main products have got CCEE, UL, VDE & TUV approval. The quality system was set up according to the requirement of ISO9000 since 1992, and has passed ISO9002 approval by DNV International Organization in July 1994, then got ISO9001 certification by British organization in 2000, by then we are both the first one who are approved by ISO9000 certification in the North-west area of China and the same occupation. We passed all the successive periodical audit and smoothly get the new certificate registered in Holland in Aug.1997; the quality system is strengthened and completed constantly. And we also got ISO18000 certificate.

        We believe we are able to supply satisfied goods and service to customers home and abroad with the most reasonable price and the shortest delivery time, on basis of our excellent quality assurance capacity, technical development capacity and rich manufacturing experiences.

 

CERTIFICATE

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter,Seller

  • Year Established:

    1976

  • Total Annual:

    240M-270M

  • Employee Number:

    390~450

  • Ecer Certification:

    Verified Supplier

Xian Xiwuer Electronic & Info. Co., Ltd. is a wholly state-owned company with a registered capital of 91.46 million RMB Yuan, owning a total assets of 315 million RMBYuan, under the jurisdiction of Xi'an State-owned Assets Supervision & Management Committee. There are about 400 employees... Xian Xiwuer Electronic & Info. Co., Ltd. is a wholly state-owned company with a registered capital of 91.46 million RMB Yuan, owning a total assets of 315 million RMBYuan, under the jurisdiction of Xi'an State-owned Assets Supervision & Management Committee. There are about 400 employees...

+ Read More

Get in touch with us

  • Reach Us
  • XIAN XIWUER ELECTRONIC AND INFO. CO., LTD
  • No.1118, Ziqiang Road, Xi'an-710015, Shaanxi, China.
  • https://www.highvoltcapacitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement