Payment Terms | L/C, T/T, Western Union, MoneyGram |
Packaging Details | ROBUST CARTON |
Test range | -120dB to +20dB |
Test accuracy | 0.1dB |
Sweep frequency accuracy | 0.01% |
Signal input impedance | 1MΩ |
Signal output impedance | 50Ω |
Signal output range | +/-20V |
In-phase test repetition rate | 99.9% |
Measuring instrument size | 355*145*270(mm) |
Instrument aluminum alloy box size | 410*360*350(mm) |
Overall heigth | 17Kg |
Brand Name | GDZX |
Model Number | ZX-BRY02 |
Certification | ISO9001 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
1A DC Winding Resistance Meter , Instrument Transformer Test Set 1μΩ Resolution
Partial Discharge Detection Transformer Testing Equipment Switchgear PD Tester
High Precision Transformer DC resistence Test Set 1mΩ - 2kΩ Measuring Range
Active Transformer Characteristic Parameter Test Equipment And Loss Test
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Packaging Details | ROBUST CARTON |
Test range | -120dB to +20dB | Test accuracy | 0.1dB |
Sweep frequency accuracy | 0.01% | Signal input impedance | 1MΩ |
Signal output impedance | 50Ω | Signal output range | +/-20V |
In-phase test repetition rate | 99.9% | Measuring instrument size | 355*145*270(mm) |
Instrument aluminum alloy box size | 410*360*350(mm) | Overall heigth | 17Kg |
Brand Name | GDZX | Model Number | ZX-BRY02 |
Certification | ISO9001 | Place of Origin | CHINA |
High Light | transformer test instruments , current transformer test set |
This Transformer Winding Deformation Tester Is For Testing Of Power Transformer (Voltage Level At Or Above 6kV) And Other Transformers With Special Purpose. The Power Transformer Is Inevitably Vulnerable To Impulse Of Various Fault Short-Circuit Current Or Physical Collision In The Process Of Operation And Transportation. The Transformer Windings May Lose Stability Under The Powerful Electro-Dynamic Force Exerted By Such Short-Circuit Current, Which Could Result In Permanent Deformations Such As Local Distortion, Swell Or Dislocation And Will Severely Affect Safe Operation Of The Transformer. Deformation Of Transformer Windings Can Be Measured With Frequency Response Analysis Method According To National Standard DL/T911-2004 For Electric Power Industry, I.E. Detect Amplitude-Frequency Response Characteristics Of Each Transformer Winding And Make Vertical Or Horizontal Comparison Of The Detection Result To Judge Possible Deformation Of The Transformer Winding Ba.
1. In the test process only need to remove the transformer connection bus.
3. Sweeping frequency up to 10MHz, scanning interval can be 0.25kHz, 0.5kHz, 1kHz for multiple analysis
4. High intelligent, auto range adjustment, auto sampling frequency adjustment.
5. Windows platform, compatible with Win98 / 2000 / XP / Win7 / Win8 / Win10 system.
6. Historical curve comparison analysis, max 6 curves observation, auto analysis and diagnosis system
7. Auto save environment parameters and testing results, color printing function.
8. Humanized software design, more convenient to use.
9. Auto complete the test after wiring, during the measurement check the historical curves or stop at any time.
10. Measurement time less than 60 seconds for every phase, 10 minutes for whole transformer windings.
1. Two sweep methods:
1) Linear sweep range (10Hz) - (10MHz) 40000 dots;resolution 0.25kHz, 0.5kHz, 1kHz
2) Section sweep range (0.5kHz) - (1MHz), 2000 dots
Test range | -120dB to +20dB |
Test accuracy | 0.1dB |
Sweep frequency accuracy | 0.01% |
Signal input impedance | 1MΩ |
Signal output impedance | 50Ω |
Signal output range | +/-20V |
Same phase test reproductivity | 99.99% |
Carrying box dimension | 410×360×350(mm) |
Total weight | 13KG |
Product Pictures
Test procedure and cautions
1. First check if the transformer is properly grounded, and the casing leads are all disconnected.
2. Record if the nameplate data and original conditions of the tested transformer are normal, and the position of tap-changers under the current test conditions and carefully enter it into the registration window.
3. Create the a subdirectory for test data file of the transformer tested; after the test, copy the measurement data to the directory, and sort the data well.
4. Data saving format: file is saved in ASCII format, and the user can read and modify it with a variety of text -editing software to.
5. Test the transformer that just stops running. Before the measurement, allow it to cool down the heat; but in the entire measurement process, stop cooling to maintain the temperature, so as to prevent temperature changes in the measuring process affecting the consistency of measurement results.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2012
Total Annual:
8 million-10 million
Employee Number:
100~120
Ecer Certification:
Verified Supplier
About GDZX Wuhan GDZX Power Equipment Co.,Ltd. is located in Wuhan, China, covering an area of 50 acres, with 6,000 m2 of factory space and 12,000 m2 of office buildings. We specialize in power testing equipment, engineering services, equipment commissioning, ope... About GDZX Wuhan GDZX Power Equipment Co.,Ltd. is located in Wuhan, China, covering an area of 50 acres, with 6,000 m2 of factory space and 12,000 m2 of office buildings. We specialize in power testing equipment, engineering services, equipment commissioning, ope...
Get in touch with us
Leave a Message, we will call you back quickly!