China factories

China factory - WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

  • China,Wuhan ,Hubei
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz
China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz

  1. China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz
  2. China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz
  3. China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz
  4. China 80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz

80KV VLF High Voltage Testing Machine VLF AC Hipot Tester 0.1Hz 0.05Hz 0.02Hz

  1. MOQ: One Set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 20 sets / month
Delivery Time 20~30 working days
Packaging Details Export standard wooden case with fumigation free
Test Principle: Very-low frequency technology principle
Usage 0.1Hz Withstand Voltage test for 35KV and below MV power cable and generator
Design Feature Two HV boosters, 30KV/50KV for single one
Component Controller,HV booster,Compensation capacitor Load
Test Frequency 0.1Hz, 0.05Hz, 0.02Hz
Max.Test Voltage 0~ 80KV(peak), continuously adjustable
Load Range: 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF
Test Accuracy No Less Than 3%
Output Waveform Good Sine Wave,Voltage, Waveform distortion ≤ 5%
HV Booster Using Way Single or In Series Connection
Duty Cycle 60mints
Brand Name Fanke High-voltage
Model Number VLF-80KV/0.1Hz
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 20 sets / month
Delivery Time 20~30 working days Packaging Details Export standard wooden case with fumigation free
Test Principle: Very-low frequency technology principle Usage 0.1Hz Withstand Voltage test for 35KV and below MV power cable and generator
Design Feature Two HV boosters, 30KV/50KV for single one Component Controller,HV booster,Compensation capacitor Load
Test Frequency 0.1Hz, 0.05Hz, 0.02Hz Max.Test Voltage 0~ 80KV(peak), continuously adjustable
Load Range: 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF Test Accuracy No Less Than 3%
Output Waveform Good Sine Wave,Voltage, Waveform distortion ≤ 5% HV Booster Using Way Single or In Series Connection
Duty Cycle 60mints Brand Name Fanke High-voltage
Model Number VLF-80KV/0.1Hz Certification ISO9001
Place of Origin China
High Light high voltage vlf hipot instrumentsvlf cable testing equipment

80KV Very Low Frequency High Voltage Test Set For Cable And Generator , AC High Voltage Testing

 

I. Product Description Of VLF Test Technology :

 

Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test technology principle can be further divided into power frequency, variable frequency (VF)and 0.1Hz very low frequency test(VLF), among which the last one is highly recommended by IEC, due to its remarkable advantages under 50KV test voltage.
 

II. Technogy feature advantage at DC test /power frequency test/VF test/ VLF test 

 

Aspects DC Power Frequency Variable Frequency 0.1Hz VLF
Equivalency Poor Good Good Good
Insulation Damage strong slight slight slight
Operation Safety relatively low relatively low relatively low high
Wiring Difficulty complicated complicated most complicated simple
Volume smallest largest large small

See from the above table , VLF test is the substitute for power frequency test. It is suitable for testing electrical equipment with large capacitance.

 

III. Product advantage and Feaure

  1. Small size and light weight. Big LCD screen and built-in printer.
  2. 0.1Hz, 0.05Hz and 0.02Hz can be chosen, which ensures a wide test range.
  3. It realizes the fully automatic voltage boost, step-down, measurement and protection as well as the manual intervention in the process of automatic voltage boost.
  4. Overvoltage protection and over-current protection. Action time is no longer than 20ms.
  5. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
  6. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
  7. Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.


IV. General Technical data:

  1. Peak voltage: 50kV
  2. Test frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
  3. Fuse: 10A
  4. Maximum load capacity: 0.5μF at 0.1Hz; 1μF at 0.05Hz; 2.5μF at 0.02Hz
  5. Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW.)
  6. Output voltage accuracy: peak voltage instability 1%; frequency instability 3%; waveform distortion: <5%.
  7. Working environment: indoor or outdoor; -10℃-+40℃; 85%RH
  8. Weight: Control unit - 5kg; HV unit: 48kg

Remarks: Capacitance of test object can not be larger than the maximum value of the test instrument. If capacitance of test object is smaller than 0.05μF, the hipot should be equipped with an auxiliary device (supplied by HV HIPOT at your option).


 

V. Other typical model

 

Model Voltage range Test Frequency Maximum load
VLF-30KV/0.1Hz 0~ 30KV 0.1HZ, 0.05HZ, 0.02HZ 5.5μF
VLF-40KV/0.1Hz 0~ 40KV 0.1HZ, 0.05HZ, 0.02HZ 5.5μF
VLF-50KV/0.1Hz 0~ 50KV 0.1HZ, 0.05HZ, 0.02HZ 5.5μF
VLF-80KV/0.1Hz 0~ 80KV 0.1HZ, 0.05HZ, 0.02HZ 2.5μF
Special requirement can be made by order

 

 

 

 

 

 

 

 

VI.Test Voltage standard by this test set

 

1 For MV and below class XLPE cable:

Test peak voltage formula: Umax=3U0

0Single-phase rated voltage of cable

Test time :60mints

 

2 For generator stator

test=1.414*βKU0,

Utest---- 0.1Hz peak test voltage (kV);

 β-------0.1Hz and 50Hz voltage equivalent factor, usually taking 1.2;

 K------ Usually take 1.3 to 1.5, generally take 1.5;

Uo----- Generator stator windings rated voltage (kV);:

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2003

  • Total Annual:

    6000000-10000000

  • Employee Number:

    100~120

  • Ecer Certification:

    Active Member

Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa... Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa...

+ Read More

Get in touch with us

  • Reach Us
  • WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
  • Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
  • https://www.high-voltagetestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details