China factories

China factory - WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

  • China,Wuhan ,Hubei
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30
China 810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30

  1. China 810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30
  2. China 810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30

810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30

  1. MOQ: One unit
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10units/2months
Delivery Time 25~45 Work Days
Packaging Details Export Standard Wooden Case With Fumigation Free
Test principle Variable frequency resonant circuit
Test Item AC withstand voltage test under 52KV , 132KV
Max.capacity 810KVA
Max. voltage 54KV , 135KV
Design feature Portable Type , Lighter Single Piece Weight, Special for On-site Installation and test
Component: V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test frequency 30-300Hz
Duty cycle 60 mints
Test accuracy No less than 1.5%
Output waveform Good sine wave
Test length of cable 5km of 35KV cable , 1km of 132KV class
Test standard IEC 60060-1:2010;IEC 62271-203:2011 for GIS, IEC 60840:2011 for XLPE cable;
Brand Name Fanke High-voltage
Model Number CHX-810KVA/54KV,135KV
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10units/2months
Delivery Time 25~45 Work Days Packaging Details Export Standard Wooden Case With Fumigation Free
Test principle Variable frequency resonant circuit Test Item AC withstand voltage test under 52KV , 132KV
Max.capacity 810KVA Max. voltage 54KV , 135KV
Design feature Portable Type , Lighter Single Piece Weight, Special for On-site Installation and test Component: V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test frequency 30-300Hz Duty cycle 60 mints
Test accuracy No less than 1.5% Output waveform Good sine wave
Test length of cable 5km of 35KV cable , 1km of 132KV class Test standard IEC 60060-1:2010;IEC 62271-203:2011 for GIS, IEC 60840:2011 for XLPE cable;
Brand Name Fanke High-voltage Model Number CHX-810KVA/54KV,135KV
Certification ISO9001 Place of Origin China
High Light high voltage resonant test systemresonant test set

Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV and 132KV Cable Test

 

I. Product Usage :


This test set model CHX-810KVA/54KV, 135KV is designed for 35KV and 110KV class XLPE cable on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 54KV or 135KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive  test or hand-over test on  AC withstand voltage test  for XLPE cables 35KV within 5km and 132KV class within 1km .

Test range of the set is as following:

1. 5km of 35kV/300mm2 cable, tested capacitance ≤0.97uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

2, 1km of 132kV/630mm2 cable , tested capacitance ≤ 0.201uF, test frequency 30-300Hz, test voltage 128kV, test time 60min.

   

 

II. General Technical Data

 

  1. Rated capacity: 810kVA;
  2. Input power: three-phase 380V voltage, frequency is 50Hz;
  3. Rated voltage: 54kV; 135kV;
  4. Rated current: 15A; 6A;
  5. Working frequency: 30-300Hz;
  6. Device output waveform: sine wave
  7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
  8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
  9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
  10. Quality factor: device itself Q≥30 (f=45Hz);
  11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
  12. Measurement accuracy: system effective value 1.5;


III. Main Components:

 

SN Name of Components Type and specification Qty. Each weight Each Dimension
1 Variable frequency power FKVF-30kW/380V 1piece 35kgs 480*480*520mm
2 Excitation transformer CQSB(J)-30kVA/2.5KV,5KV 1piece 130kgs 550*550*580mm
3 HV resonant test reactor CHX(kf)-81kVA/27kV/34H 10pieces 75kgs D480*H520mm
4 Capacitive divider TRF-150kV/2000pF 1set 30kgs D200*H1250mm
5 Special test accessories   1set    

 

 
 
 
 
 
 
 
 
 
 

IV. Test priciple :

 
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )
 
 
V. Main Measuring and control software panel:  

 Note: This is the software panel before start test for parameter setting
 

 

 
VI.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Insulation supporting base
  • corona ring for 135KV test
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .

 
VII. Other Optional Model 

 

1. For  GIS on-site  test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-135KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-270KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-216KVA/216KV 27KV*8 1A 216KVA For 123KV and below GIS
CHX-270KVA/270KV 27KV*10 1A 270KVA For 145KV and below GIS
CHX-275KVA/275KV 275KV 2A 275KVA For 170KV and below GIS
Special requirement can be made by order

 

 

2. For 45KV  XLPE cable on-site test 

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-108/54 54KV 2A 108KVA 45kV cable≤1km
CHX-216/54 54KV 4A 216KVA 45kV cable≤2km
CHX-324/54 54KV 6A 324KVA 45kV cable≤3km
CHX-432/54 54KV 8A 432KVA 45kV cable≤4km
CHX-540/54 54KV 10A 540KVA 45kV cable≤5km
CHX-1080/54 54KV 20A 1080KVA 45kV cable≤10km
Special requirement can be made by order

 

3. For 66KV XLPE cable on-site test

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-160/80 80KV 2A 160KVA 66kV cable≤0.5km
CHX-320/80 80KV 4A 320KVA 66kV cable≤1km
CHX-640/80 80KV 8A 640KVA 66kV cable≤2km
CHX-960/80 80KV 12A 960KVA 66kV cable≤3km
CHX-1280/80 80KV 16A 1280KVA 66kV cable≤4km
CHX-1600/80 80KV 20A 1600KVA 66kV cable≤5km
CHX-3200/80 80KV 40A 3200KVA 66kV cable≤10km
CHX-9600/80 80KV 120A 9600KVA 66kV cable≤20km
Special requirement can be made by order

 

 

 

VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2003

  • Total Annual:

    6000000-10000000

  • Employee Number:

    100~120

  • Ecer Certification:

    Active Member

Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa... Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa...

+ Read More

Get in touch with us

  • Reach Us
  • WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
  • Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
  • https://www.high-voltagetestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement