Payment Terms | T/T |
Supply Ability | 20 sets / month |
Delivery Time | 15-20working days |
Packaging Details | Export standard wooden case with fumigation free |
Usage | CT PT Volt-ampere Characteristics Tester ,Demagnetization |
Test Items | CT/PT volt-ampere ,CT/PT ratio, DC resistance, |
Other items | secondary load test functions, angular phase difference, secondary withstand voltage |
Advantage | Variable frequency method, portable type, Full functions |
Test standard | IEC60044-1, IEC60044-6 |
Accuracy | < 0.2% |
Brand Name | Fanke High-voltage |
Model Number | FK-401 |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
View Detail Information
Explore similar products
SF6 Gas Insulation Inflatable Experimental High Voltage Transformer
SF6 Gas Insulation Inflatable Experimental High Voltage Transformer
2000A~5000A CT PT Testing Equipment Secondary Current Injection Test Kit One
150Hz CT PT Testing Equipment Three Times Frequency Power Generator
Product Specification
Payment Terms | T/T | Supply Ability | 20 sets / month |
Delivery Time | 15-20working days | Packaging Details | Export standard wooden case with fumigation free |
Usage | CT PT Volt-ampere Characteristics Tester ,Demagnetization | Test Items | CT/PT volt-ampere ,CT/PT ratio, DC resistance, |
Other items | secondary load test functions, angular phase difference, secondary withstand voltage | Advantage | Variable frequency method, portable type, Full functions |
Test standard | IEC60044-1, IEC60044-6 | Accuracy | < 0.2% |
Brand Name | Fanke High-voltage | Model Number | FK-401 |
Certification | ISO9001 | Place of Origin | Wuhan ,China |
High Light | ct pt analyzer ,ct pt test set |
Portable CT/PT Analyzer , CT/PT Excitation Characteristics Tester ,Variable Frequency Testing
I. Product Description
FK-401 CT/PT Analyzer is a kind of professional testing equipment for CT/PT electric equipments. It can meet all kinds of CT (e.g.: protection, measuring, TP) excitation characteristics ( i.e. voltage characteristics ), ratio, polarity , secondary winding resistance, secondary load, ratio error and phase angle error and other testing requirements , and is also compliant with various types of PT electromagnetic unit excitation characteristics, ratio, polarity , secondary winding resistance , ratio error and phase angle error and other testing requirements.
II. Main Performed Test items:
III. Technical features
1. Full-featured , meet all kinds of CT (e.g.: protection, measuring, TP) excitation characteristics ( i.e. voltage characteristics ), ratio, polarity , secondary winding resistance, secondary load, ratio error and phase angle error and other testing requirements , also compliant with various types of PT electromagnetic unit excitation characteristics, ratio, polarity , secondary winding resistance , ratio error and phase angle error and other testing requirements.
2. Automatically gives the knee voltage / current, 10% ( 5% ) error curve , accuracy limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr), saturated and unsaturatied inductors and others CT, PT parameters.
3. Meet IEC60044-1, IEC60044-6 CT/PT standard.
4. Based on an advanced low-frequency testing theory, able to test knee point of the CT test up to 30KV.
5.Device can store 2000 groups of test data, non-volatile. After the test is completed with U disk to the PC data analysis software, and generate reports in WORD file.
6. Testing is simple and convenient, one button operation completes CT resistance, excitation, ratio and polarity tests,.Except for load test , various other CT tests are using the same wiring.
7. Easy to carry, instrument weight<9kg
IV. Test Data
Testing purposes | Protective CT |
Output | 0~180Vrms, 12Arms,36A(peak value) |
Voltage measurement accuracy | ±0.2% |
CT ratio measurement | Range: 1~30000 |
Accuracy: ±0.2% | |
PT ratio measurement | Range: 1~10000 |
Accuracy: ±0.2% | |
Phase measurement | Resolution: 0.5min |
Accuracy: ±5min | |
Secondary winding resistance measurement | Range: 0~300Ω |
Accuracy: 2%±2mΩ | |
AC load measurement | Range: 0~300VA |
Accuracy: 2%±0.2VA | |
Input supply voltage | AC220V±10%, 50Hz |
Work Environment | Temperature:-10℃ ~ 50℃, humidity≤90% |
Dimension & weight | Dimension: 340×300×150mm3, weight≤9kg |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
6000000-10000000
Employee Number:
100~120
Ecer Certification:
Active Member
Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa... Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa...
Get in touch with us
Leave a Message, we will call you back quickly!