Payment Terms | L/C, T/T |
Supply Ability | 10sets / 2months |
Delivery Time | 25~35 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | AC Withstand Voltage Test for HV cable or GIS |
MAX.Capacity | 3000KVA or OEM |
Max.Voltage | 150KV or OEM |
Test Frequency | 20-300Hz |
Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% |
Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
Brand Name | Fanke High-voltage |
Model Number | CHX-3000KVA/150KV |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
View Detail Information
Explore similar products
High Accuracy Hv Voltage Tester , High Voltage Apparatus For Power Substation
810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30
45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation
132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 10sets / 2months |
Delivery Time | 25~35 Working Days | Packaging Details | Export Standard Wooden Case With Fumigation Free |
Test Principle | Variable Frequency Resonant Circuit | Usage | AC Withstand Voltage Test for HV cable or GIS |
MAX.Capacity | 3000KVA or OEM | Max.Voltage | 150KV or OEM |
Test Frequency | 20-300Hz | Duty Cycle | 60 mints or OEM |
Test Accuracy | No less than 1.5% | Special For | On-site Test For long HV XLPE cable and GIS |
Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable | Brand Name | Fanke High-voltage |
Model Number | CHX-3000KVA/150KV | Certification | ISO9001 |
Place of Origin | Wuhan ,China | ||
High Light | high voltage resonant test system ,high voltage testing of electrical equipments |
Variable Frequency Resonant Withstand Voltage Test Reactor For Long HV XLPE Cable
I. Application :
The high voltage test reactor is HV booster or generator in the variable frequency resonant withstand voltage circuit, it has large capacity and HV for one piece with higher Quality factor putput . it is special for the high voltage XLPE cable test with longer distance .
Fanke company can finish the design and produce the goods according to all kinds of customer's requirement . such as cylinder type and iron tank type .
Test reactor can be produced to be 130KV,150KV,155KV,200KV, 250KV, 300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~5A,10A,15A,20A,25A,30A.
II. Test priciple figure:
VF: Variable Frequency Power Supply Source which is control and measurement part in the test circuit.
T : Excitation Transformer which provide the exciting voltage for HV test reactor
L : Test Reactor which is resonant inductance in the LC circuit and produce the test voltage
Cx: Tested Equipment
MOA1: Lightning Arrestor is protection part on the excitation transformer
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm ) which is HV voltage measurement part
III. General Technical data:
IV.Accessories
V. Typical model of test reactors
1 Optional model for 132KV class XLPE cable on-site withstand voltage test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-775KVA/155KV | 155KV | 5A | 775KVA | 132kV cable≤1km |
CHX-1550KVA/155KV | 155KV | 10A | 1550KVA | 132kV cable≤2km |
CHX-2325KVA/155KV | 155KV | 15A | 2325KVA | 132kV cable≤3km |
CHX-3100KVA/155KV | 155KV | 20A | 3100KVA | 132kV cable≤4km |
CHX-3875KVA/155KV | 155KV | 25A | 3875KVA | 132kV cable≤5km |
CHX-7750KVA/155KV | 155KV | 50A | 7750KVA | 132kV cable≤10km |
CHX-12400KVA/155KV | 155KV | 80A | 12400KVA | 132kV cable≤16km |
CHX-15500KVA/155KV | 155KV | 100A | 15500KVA | 132kV cable≤20km |
Special requirement can be made by order |
Note :Tested cable voltage class≤ 132kV, 0.25uF/km
2 Optional model for 230KV class XLPE cable on-site withstand voltage test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-2020KVA/255KV | 255KV | 8A | 2020KVA | 220~230kV cable≤1km |
CHX-4080KVA/255KV | 255KV | 16A | 4080KVA | 220~230kV cable≤2km |
CHX-6120KVA/255KV | 255KV | 24A | 6120KVA | 220~230kV cable≤3km |
CHX--8160KVA/255KV | 255KV | 32A | 8160KVA | 220~230kV cable≤4km |
CHX--10200KVA/255KV | 255KV | 40A | 10200KVA | 220~230kV cable≤5km |
CHX--20400KVA/255KV | 255KV | 80A | 20400KVA | 220~230kV cable≤10km |
CHX--25500KVA/255KV | 255KV | 100A | 25500KVA | 220~275kV cable≤12.5km |
Special requirement can be made by order |
Note :Tested cable voltage class≤ 230kV, 0.25uF/km
3 Optional model for 330KV class XLPE cable on-site withstand voltage test
Model | Rated voltage | Rated output current | Rated output capacity | Max Application |
CHX-3500KVA/350KV | 350KV | 10A | 3500KVA | 330kV cable≤1km |
CHX-7000KVA/350KV | 350KV | 20A | 7000KVA | 330kV cable≤2km |
CHX-10500KVA/350KV | 350KV | 30A | 10500KVA | 330kV cable≤3km |
CHX-14000KVA/350KV | 350KV | 40A | 14000KVA | 330kV cable≤4km |
CHX-21000KVA/350KV | 350KV | 60A | 21000KVA | 330kV cable≤5km |
CHX-28000KVA/350KV | 350KV | 80A | 28000KVA | 330kV cable≤10km |
Special requirement can be made by order |
Note :Tested cable voltage class≤ 330kV, 0.25uF/km
4 Optional other model for long XLPE cable on-site withstand voltage test
Model | Rated voltage | Rated output current | Rated output capacity | Application (From 20Hz starting) |
CHX-2600KVA/130KV | 130KV | 10A,20A | 1300KVA | For U0=64KV and below cable |
CHX-3000KVA/150KV | 150KV | 10A, 20A | 3000KVA | For U0=87KV and below cable |
CHX-10000KVA/250KV | 250KV | 20A, 40A | 10000KVA | For U0=127KV and below cable |
CHX-20000KVA/250KV | 250KV | 20A, 80A | 20000KVA | For U0=127KV and below cable |
CHX-21000KVA/350KV | 350KV | 20A, 60A | 21000KVA | For U0=230KV and below cable |
CHX-42000KVA/350KV | 350KV | 20A, 80A | 42000KVA | For U0=230KV and below cable |
Special requirement can be made by order |
Note : XLPE cable test voltage is considering as 1.7U0
5 Optional model for HV or EHV class cable and GIS On-site AC hipot test
Model | Rated voltage | Rated output current | Rated output capacity | Application (From 20Hz starting) |
CHX-2600KVA/130KV,260KV | 130KV,260KV | 20A@130KV | 2600KVA | For U0=64KV cable For 72.5KV class GIS |
10A@260KV | For U0=127KV cable For 145KV class GIS | |||
CHX-9000KVA/150KV,300KV | 150KV,300KV | 60A@150KV | 9000KVA | For U0=87KV cable For 72.5KV class GIS |
30A@300KV | For U0=160KV cable For 170KV class GIS | |||
CHX-10000KVA/250KV,500KV | 250KV,500KV | 40A@250KV | 10000KVA | For U0=127KV cable For 145KV class GIS |
20A@500KV | For U0=290KV cable For 362KV class GIS | |||
CHX-20000KVA/250KV,500KV | 250KV,500KV | 80A@250KV | 20000KVA | For U0=127KV cable For 145KV class GIS |
40A@500KV | For U0=290KV cable For 362KV class GIS | |||
CHX-21000KVA/350KV,700KV | 350KV,700KV | 60A@350KV | 21000KVA | For U0=190KV cable For 170KV class GIS |
30A@700KV | For U0=290KV cable For 550KV class GIS | |||
Special requirement can be made by order |
VI. On-site test standard table from IEC 60840:2011 and IEC 62067:2011 for XLPE cable
VII. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
6000000-10000000
Employee Number:
100~120
Ecer Certification:
Active Member
Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa... Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa...
Get in touch with us
Leave a Message, we will call you back quickly!