Payment Terms | T/T |
Supply Ability | 10sets /month |
Delivery Time | 10-15 Working Days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Product name | Cable Fault Distance Locator |
Appilcation | Cable Fault Locating And Underground Path Tracing |
Cable class | No More Than 35KV |
Detecting way | LV impulse method, impulse HV flash-over method, multiple pulse method |
Fault locating error | ±0.2m |
Data storgae | 8G |
Brand Name | Fanke High-voltage |
Model Number | FKDL2000 |
Certification | ISO9001 |
Place of Origin | Wuhan ,China |
View Detail Information
Explore similar products
Variable Frequency Resonant Withstand Ac High Voltage Test Set For Long HV XLPE
Easy Radiation High Voltage Cable Testing Equipment Underground Cable Identifier
High Accuracy High Voltage Cable Testing Equipment Cable Heat Cycle Test Systems
Durable High Voltage Measurement Equipment , Cable Fault Location Equipment
Product Specification
Payment Terms | T/T | Supply Ability | 10sets /month |
Delivery Time | 10-15 Working Days | Packaging Details | Export Standard Wooden Case With Fumigation Free |
Product name | Cable Fault Distance Locator | Appilcation | Cable Fault Locating And Underground Path Tracing |
Cable class | No More Than 35KV | Detecting way | LV impulse method, impulse HV flash-over method, multiple pulse method |
Fault locating error | ±0.2m | Data storgae | 8G |
Brand Name | Fanke High-voltage | Model Number | FKDL2000 |
Certification | ISO9001 | Place of Origin | Wuhan ,China |
High Light | ac high voltage test set ,high voltage cable identifier |
Underground Cable Route and Cable Fault Distance Locator, Distribution Cable Fault Detector
I. Application :
FKDL2000 cable fault distance locator is a kind of Integrated testing apparatus , which is made from the fault detecting test host, cable path tracing signal generator, cable tracing path signal receiver and cable fault locator, etc.The host machine, including the integrated computer, the low-voltage pulse generator, and the data processor, is used to test fault distance and measure cable length and wave propagation velocity in cable.The sine wave signal with frequency of 30KHz and amplitude peak of 30V produced by path signal generator is used to find the cable path.Path signal receiver is used for receiving the signal path, and used to find the cable louding and estimate the cable burial depth. Fault locator is used for fault exact positioning.The detecting way of the has three kinds of LV impulse method, impulse HV flash-over method, multiple pulse method. The optional part is DC high voltage booster and control cabinet , which is used for providing a breakdown voltage to enlarge the insulation damaged and easily repairing .
The Integrated testing apparatus is able to test cable fault at different voltage levels below 35KV. It can test cable fault of different cable sections, different dielectric and different cable materials. Can test open-circuit cable fault, short-circuit cable fault, low-resistance cable fault, high-resistance leakage cable fault and high-resistance flash-over cable fault.
II. Technical index:
1, Fault measuring system
2, Cable Tracing Path signal generator Part
3, Cable Fault Locator Part
4. Other Technical Data
Model | FKDL2000 |
Application | Can test cable fault at different voltage levels below 35KV. Can test cable fault of different cable sections, different dielectric and different cable materials. Can test open-circuit cable fault, short-circuit cable fault, low-resistance cable fault, high-resistance leakage cable fault and high-resistance flash-over cable fault. |
Cables | Can test all faults of railway communication control cable, streetlight cable and airport signal cable. |
Display mode | 12.1in industrial LCD touch screen (Windows XP platform) |
Test method | LV impulse method, impulse HV flash-over method, multiple pulse method |
Storage | 8G |
Test distance | no less than 60Km |
Operate | Touch pen and mouse |
Min. test distance (non-detection area): | 0-5m or without |
Locating error | ±0.2m |
Test error | system error is no ore than ±1% |
Multiple pulse generator | Impulse voltage ≤40KV |
Resolution | V/fm,V is transmitting velocity m/μs |
software cursor | 0.10m. |
Sampling frequency | 6.25MHz,12.5MHz,25MHz,50MHz,100MHz (Adaptive pulse width). |
Power source and power consumption | AC 220V±10%, power consumption≤15W |
Standby time | continuous working 6 hours |
Host weight | 6.2KG |
Dimension: | 180mm×300mm×400mm |
Temperature | -20℃- 40℃ |
Relative humidity | ≤80% |
III. Configuration:
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
6000000-10000000
Employee Number:
100~120
Ecer Certification:
Active Member
Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa... Founded in 2003, FANKE is the domestic leader specializing in designing and manufacturing HV test, measurement and overhaul equipments. In 2003, Wuhan HIGHVOLT Co.,Ltd is established as our subsidiary. We provide a diversity of complete testing solutions and one-stop service for electric power compa...
Get in touch with us
Leave a Message, we will call you back quickly!