Products
Manufacturer of a wide range of products which include Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,PD Free Partial Discharge...
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
Payment Terms | L/C, T/T |
Supply Ability | 5units/2months |
Delivery Time | 35~45 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Resonant Circuit |
Usage | AC Hipot Test for large generator stator or rotor winding |
Max.capacity: | 3750KVA |
Max. Voltage | 65KV |
Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
Test Frequency | 50Hz or 60Hz |
Duty Cycle | 10mints or made by order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
Note | PD free Type can be made by order |
Brand Name | Fanke High-voltage |
Model Number | CHX-L-3750KVA/65KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C , T/T |
Supply Ability | 5units/2months |
Delivery Time | 45~75 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Test Transformer Circuit |
Test Standard | IEC60060-1:2010 |
Max.capacity | 400KVA |
Max. Voltage | 400KV |
Usage | AC Hipot test in the factory quality inspection for Power transformers, gas-insulated switchgears, bushings, arresters and insulation materials |
Component: | Control Console,Voltage Regulator,Cylinder Type Test Transformer, Protection resistance,And Voltage Divider |
Test Frequency | 50Hz Or 60Hz |
Duty Cycle | 60mints Or Made By Order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
PD level | PD free , No corona , No more than 5pC |
Brand Name | Fanke High-Voltage |
Model Number | CQSB-400KVA/400KV |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C , T/T |
Supply Ability | 5units/2months |
Delivery Time | 45~75 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Power Frequency Test Transformer Circuit |
Test Standard | IEC60060-1:2010 |
Max.capacity | 400KVA |
Max. Voltage | 400KV |
Usage | AC Hipot test in the factory quality inspection for Power transformers, gas-insulated switchgears, bushings, arresters and insulation materials |
Component: | Control Console,Voltage Regulator,Cylinder Type Test Transformer, Protection resistance,And Voltage Divider |
Test Frequency | 50Hz Or 60Hz |
Duty Cycle | 60mints Or Made By Order |
Test Accuracy | No Less Than 1.0% |
Output Waveform | Pure Sine Wave |
PD level | PD free , No corona , No more than 5pC |
Brand Name | Fanke High-Voltage |
Model Number | CQSB-400KVA/400KV |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Impulse current method for PD detecting |
Usage | Digital Partial Discharge Test |
Refer standard | IEC60270 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Application | Power transformer ,CB, bushing, CT,PT ,discloser and so on |
PD Display | Ellipse, Expand, Beeline, Win XP operation |
Capacitance range | 6pF~250uF can be detected |
Optional model | 2channels , 4channels, 6channels |
Sensitivity | 0.1pc |
Brand Name | Fanke High-Voltage |
Model Number | XD210X series |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Impulse current method for PD detecting |
Usage | Digital Partial Discharge Test |
Refer standard | IEC60270 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Application | Power transformer ,CB, bushing, CT,PT ,discloser and so on |
PD Display | Ellipse, Expand, Beeline, Win XP operation |
Capacitance range | 25pF~6000pF can be detected |
Optional model | 2channels , 4channels |
Error | ±5% |
Brand Name | Fanke High-Voltage |
Model Number | JFD-2000 series |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Impulse current method for PD detecting |
Usage | Digital Partial Discharge Test |
Refer standard | IEC60270 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Application | Power transformer ,CB, bushing, CT,PT ,discloser and so on |
PD Display | Ellipse, Expand, Beeline, Win XP operation |
Capacitance range | 6pF~250uF can be detected |
Optional model | 2channels , 4channels, 6channels |
Sensitivity | 0.1pc |
Brand Name | Fanke High-Voltage |
Model Number | XD210X series |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: 15000~25000 USD /Unit
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Impulse current method for PD detecting |
Usage | Partial Discharge Test |
Refer standard | IEC60270 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Application | power transformer ,CB, bushing, CT,PT ,discloser and so on |
PD Display | Ellipse, Expand, Beeline |
Capacitance range | 6pF~250uF can be detected |
Brand Name | Fanke High-Voltage |
Model Number | JF2002 |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: 15000~25000 USD /Unit
Payment Terms | T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Impulse current method for PD detecting |
Usage | Partial Discharge Test |
Refer standard | IEC60270 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Application | power transformer ,CB, bushing, CT,PT ,discloser and so on |
PD Display | Ellipse, Expand, Beeline |
Capacitance range | 6pF~250uF can be detected |
Brand Name | Fanke High-Voltage |
Model Number | JF2002 |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One unit
Price: 15000~25000 USD /Unit
Payment Terms | L/C, T/T |
Supply Ability | 10units/month |
Delivery Time | 20~25 work days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | High-frequency current sensor (HFCT) measurement and Ultrasonic detecting technology |
Usage | Patrol type Partial Discharge Detecting Tester For Live XLPE cable And Power Transformer |
Refer standard | GB / T 7354 Partial discharge measurement ;DL/T 417 Guideline for local measurement of partial discharge of electric equipment ; |
Brand Name | Fanke High-Voltage |
Model Number | PPD8609A |
Certification | ISO9001 |
Place of Origin | China |