China factories

China factory - Nanjing Saiko Controls Co.Ltd

Nanjing Saiko Controls Co.Ltd

  • China,Nanjing ,Jiangsu
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element
China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element

  1. China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element
  2. China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element
  3. China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element
  4. China Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element

Wireless Fan Coil Room Thermostat High Accuracy With NTC Sensing Element

  1. MOQ: 64pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T, Western Union,Paypal
Supply Ability 10000pcs/month
Delivery Time 10 working days
Packaging Details 64pcs in one carton
Sensing element NTC
Dimension 86*86*13mm
Rated load 200W
Set-point range 5~35℃
Accuracy ±1℃
Supply 50/60Hz 220V AC ±10%
Brand Name Saiko
Model Number SK306
Certification CE,RoHs
Place of Origin Jiangsu

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union,Paypal Supply Ability 10000pcs/month
Delivery Time 10 working days Packaging Details 64pcs in one carton
Sensing element NTC Dimension 86*86*13mm
Rated load 200W Set-point range 5~35℃
Accuracy ±1℃ Supply 50/60Hz 220V AC ±10%
Brand Name Saiko Model Number SK306
Certification CE,RoHs Place of Origin Jiangsu
High Light heating and cooling thermostatfan coil room thermostat

 

86mm x 86mm x13mm Latest Wireless Digital Room Fan Coil Thermostat
 

  The SK306 series thermostat is a stand-alone microprocessor based thermostat with LCD display .The thermostats are designed to control room temperature by way of on/off controlling the fan coil units(with or without motorized valves), air damper or electric heaters in heating, cooling and ventilation applications.
 
To turn the thermostat on/off
1. The power on and off of the thermostat can be realized through manual operation.
The power on/off condition can be switched through press on/off button.
2. The primary power up of the system is under the power off condition.
 
To adjust thermostat temperature
1. Press △ or ▽ to adjust the temperature, the flashing default temperature is 20ºC;
2. Press △ to increase temperature by 1ºC;
3. Press ▽ to decrease temperature by 1ºC;
4. The system will exit automatically without any operation in 5 seconds.
Temperature calibration
When the thermostat is in stand by state, press "" for 3 seconds, while display "XX" ºC (RT symbol doesn't show), press "up" or "down" key to adjust the temperature to the correct value, it will accept automatically in 5 seconds.
 
Parameters

Power supply 230VAC,50-60Hz
Setpoint range 5~35ºC
Setting unit 1ºC/step
Accuracy ±1ºC
Display 50*36mm LCD screen
Mode setting Heating,cooling and ventilation


Specifications

Mounting Embeded mounting
Switch current rating Resistive:2A/4A.Inductive:1A/2A
Temperature sensor NTC Thermistor 100K
Enclosure Fire Retardant PC ABS
Dimensions 86*86*13mm
Hole pitch 60mm


Heating/Cooling setting
Press "M" key to select heating or cooling mode.
 
Fan speed setting
With each press of the "fan speed key", the thermostat will change the speed among low, medium, high and auto speed. In Auto" mode, the speed automatically change according to the difference between room temp. and set temp.
 
To set timer
When the thermostat is turned on, press "" until the time start flashing, using the up or down key to set the desired time. It will accept automatically in 5 seconds. The thermostat is now set to be turned on/off at the desired time.
 
Display Symbol

Mounting

1. The thermostat is flush mount, a back box of ideally 45mm depth should be sunk into the wall prior to the installation.
2. The installation should be carried out by a qualified electrician.
3. Choose a location about 5 feet (1.5 meters) above the floor with good air circulation.
4. To avoid electrician shock and to prevent damage to the furnace, air conditioners, and thermostat, disconnect the power
supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance.
 
Wiring dirgram

 
 
 
 
 
 


 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2015

  • Employee Number:

    20~40

  • Ecer Certification:

    Site Member

  Heated floor thermostat.com   We started producing electric in-floor heating in Jiangsu,China almost eight years ago in 2011 and have been growing steadily ever since. In 2015 we started selling our own specially-designed lines of in-floor heating products and two years later once...   Heated floor thermostat.com   We started producing electric in-floor heating in Jiangsu,China almost eight years ago in 2011 and have been growing steadily ever since. In 2015 we started selling our own specially-designed lines of in-floor heating products and two years later once...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Saiko Controls Co.Ltd
  • No.40 Ailing Road, Moling Street, Jiangning District, Nanjing
  • https://www.heatedfloorthermostat.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement