Payment Terms | T/T, Western Union,Paypal |
Supply Ability | 5000pcs/ month |
Delivery Time | within 1-3 working days after payment |
Packaging Details | one unit in one box |
DC Power supply | 9-28V DC (Standard adapter: DC 12V/1.5A) |
Protocol | Master poll or Slaver |
Digital inputs | 4 Digital input(dry contacts) |
Digital outputs | 4 Drivable relay outputs |
Com Interface | Rs232 or Rs485 |
Exterior dimension | 95 X 64 X 25mm |
Weight | 256g |
Usage | modbus io module |
Support | GSM/GPRS/3G/4G |
Warranty | 1 Year |
Brand Name | CWT |
Model Number | CWT5002-1 |
Certification | CE,RoHS |
Place of Origin | China |
View Detail Information
Explore similar products
master slave generator gsm gprs rtu modbus 8 digital IO 4 relay output
CWT5002 GSM GPRS RTU modbus industry module , modbus data acquisition,gprs data
GPRS GSM Modbus Protocol Data Logger, RS485/RS232, Modbus Master/Slave
GSM Modbus GSM Telemetry Remote controller RTU, 4I/O, 1 RS232, RS485
Product Specification
Payment Terms | T/T, Western Union,Paypal | Supply Ability | 5000pcs/ month |
Delivery Time | within 1-3 working days after payment | Packaging Details | one unit in one box |
DC Power supply | 9-28V DC (Standard adapter: DC 12V/1.5A) | Protocol | Master poll or Slaver |
Digital inputs | 4 Digital input(dry contacts) | Digital outputs | 4 Drivable relay outputs |
Com Interface | Rs232 or Rs485 | Exterior dimension | 95 X 64 X 25mm |
Weight | 256g | Usage | modbus io module |
Support | GSM/GPRS/3G/4G | Warranty | 1 Year |
Brand Name | CWT | Model Number | CWT5002-1 |
Certification | CE,RoHS | Place of Origin | China |
GSM GPRS RTU modbus industry data Logger
Support 3G WCDMA / 4G LTE Version
E-mail: lisa(at)mobq2000.com
Skype: lisali1220
WhatsApp: 0086 -13652426178
Mobile: 00 86 1365242618
QQ : 2946370755
Advance features
1. Adopted highly integrated industrial CPU
2. Easy used GUI configure software
3. Reliable performance with built-in double watchdog
4. Low maintenance, 24×7 operation
5. Support ring call when alarm
6. Temperature sensor (optional)
7. Internal battery and providing power cut off alarm
Modbus feature
1. Modbus RTU protocol on RS232 or RS485, monitor modbus slave
2. Read or write 32 registers (coil or input registers) on Modbus via GPRS or SMS
3. Upload data to server when coils are triggered
4. Can preset normal range for input registers; upload data to server when above the normal range
5. Support SMS operation (read or write registers)
GPRS feature
1. Support connects 4 servers, the servers must connect internet and have static public IP address or Dynamic Domain name
2. GPRS Transmission base on TCP/IP
3. Support modbus TCP protocol
4 digital inputs feature
1. Upload data when inputs are triggered
2. Upload input status on schedule
3. Can be reuse as pulse counter input
4. SMS alarm when inputs are triggered
5. NO or NC type can be preset
6. Configurable for alarm and recover sms
7. Remote query inputs status
4 relay drivable outputs feature
1. Multiple output type can be preset
2. Remote On/Off/Pulse outputs via GPRS or sms
3. Configurable for pulse time
4. Remote query outputs status via GPRS or sms
5. Outputs can be activated by alarm or call
6. Outputs can be activated on schedule
4 analog inputs feature
1. Can preset normal range for AD input, upload data to server when above the normal range.
2. Current values can be query by server or sms
3. Configurable for alarm and recover SMS
4. Configurable for alarm ensure time
5. Configurable for alarm delay time
6. Support offset and gain
Specifications
DC Power supply: 12-24V DC (Standard adapter: DC 12V/1.5A)
Power consumption: 12V input Max. 150mA/Average 50mA
Frequency range: Quad-frequency 900/1800/850/1900HMz
SIM Card: Supporting 3V SIM Card
Antenna: 50 Ω SMA Antenna interface
Serial port: Selectable RS-232/485
Temperature range: -30°C ~ +70 °C
Humidity range: Relative humidity 95%
Digital Input: 4 digital inputs (Dry contact)
Output: 4 drivable relay outputs (open-collector outputs)
Output drive voltage: Equal to input DC voltage
Output drive power: Drive voltage ≤35V, drive current ≤500mA
Exterior dimension: 95×63×25mm
Weight: 256 g
Screenshot of Program Software:
Application:
Digital Input: 4 digital inputs (Dry contact)
Output: 4 drivable relay outputs (open-collector outputs)
Output drive voltage: Equal to input DC voltage
Output drive power: Drive voltage ≤35V, drive current ≤500mA
Exterior dimension: 95×63×25mm
Weight: 256 g
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
50% - 60%
Employee Number:
50~100
Ecer Certification:
Active Member
Wireless Remote Monitoring Solutions Whatever term you use for Telemetry, whether it's remote monitoring, M2M, Machine2Machine, Machine2Man or even Man2Machine then CWT wire free telemetry products will serve you well. Our Telemetry Solutions have been designed with the user in mind, ... Wireless Remote Monitoring Solutions Whatever term you use for Telemetry, whether it's remote monitoring, M2M, Machine2Machine, Machine2Man or even Man2Machine then CWT wire free telemetry products will serve you well. Our Telemetry Solutions have been designed with the user in mind, ...
Get in touch with us
Leave a Message, we will call you back quickly!