Payment Terms | T/T, Western Union |
Vacuum degree reached: | ≤-0.080MPa; |
Vacuum setting resolution: | ± 0.01Pa. |
Sampling frequency: | about 10ms per box |
Brand Name | GERUISI |
Model Number | GRS-5V100A-16L |
View Detail Information
Explore similar products
5V60A-48CH Power Battery Negative Pressure Forming Machine For Prismastic Cell
5V100A 64CH- Energy Feedback Lithium Battery Formation Machine
Helium Mass Spectrometer Leak Detector
2000W/4000W Laser Welding Machine for Prismastic Cell, Cylindrical cell or
Product Specification
Payment Terms | T/T, Western Union | Vacuum degree reached: | ≤-0.080MPa; |
Vacuum setting resolution: | ± 0.01Pa. | Sampling frequency: | about 10ms per box |
Brand Name | GERUISI | Model Number | GRS-5V100A-16L |
High Light | Negative Pressure lithium battery manufacturing equipment ,Prismastic lithium battery manufacturing equipment ,Prismastic lithium ion battery assembly machine |
Parameteres:
1. Suitable for aluminum shell battery size:
2. Charging voltage setting range: DC 0~4.5V;
3. Discharge voltage setting range: DC 2~4.5V;
4. Charging and discharging current setting range: DC 0.1 ~ 150A;
5. Voltage accuracy: ±(0.1%RD +0.1%FS);
6. Current accuracy: ±(0.1%RD +0.1%FS);
7. Voltage resolution: 1mV;
8. Voltage stability: ≤ ± 0.1%;
9. Current stability: ≤ ± 0.1%;
10. Power accuracy: ±(0.1%RD +0.1%FS);
11. Current response time: current output at 150A hardware response time: ≤ 50ms;
12. Time setting range: any setting within 0~999 minutes, the time unit is h, min and s respectively, and the resolution is 0.1s;
13. Time accuracy: ≤ ± 0.1%;
14. Recording method: charging recording time, discharging recording time, still recording time, global recording time;
15. Recording frequency: 100ms ~ 65535s
16. Sampling frequency: about 10ms per box;
17. Charging mode: constant current voltage limit; constant current constant voltage;
18. Charge cut-off condition: voltage; current; time; capacity;
19. Discharge mode: constant current discharge;
20. Discharge cut-off condition: voltage; current; time; capacity;
21. Number of steps: 1-32 steps, with nested loop function;
22. Continuous working time: the power of the equipment should meet the requirements of full load of all channels, 365*24 hours uninterrupted operation;
23. Software features:
1) Local test detailed data storage, you can view the current test data and historical data of each channel at any time, there are two ways of corresponding data and curve, and support the export of EXCE reports in a single or batch form, in addition, you can set the test end automatic guide data as needed.
2) Support capacity sorting, can sort the battery;
3) Support the test end qualified judgment, according to the specified cycle capacity, voltage, time and other information to judge the PASS/NG results;
4) Support all kinds of step protection and global voltage, current abnormal protection, and abnormal alarm;
5) Support database server background storage;
6) Software offline protection;
7) The software offers free upgrades.
8) The software supports all kinds of continuations, such as manual suspension of continuations, software closure of continuations, interruption of power failure, interruption of equipment communication, and abnormal stop of continuations;
24. Protection function
1) Data abnormal recovery;
2) Software over-voltage, under-voltage, over-current, under-current, over-capacity protection
3) The range of voltage and current protection value can be set, and can be prompted and recorded after protection;
4) Set the high alarm lamp to prompt the status;
5) A smoke alarm is installed, and the machine stops running and alarms when a smoke alarm occurs;
6) After the equipment is stopped by the alarm, the unfinished process can be continued from the interrupted position without starting the process from the beginning;
7) If the communication between the lower computer and the upper computer is interrupted and the communication returns to normal, the work can be continued according to the original process;
8) When the equipment is abnormally powered off, the current process step can be continued;
25. Three-color lamp display status
1) Standby (no process is sent or the process is finished)-yellow light;
2) In the process (sleep, charge, discharge)-green light;
3) System failure (overvoltage, overcurrent, hardware failure, etc.) ---- red light.
26. Vacuum part technical parameters:
Company Details
Business Type:
Manufacturer
Ecer Certification:
Site Member
Wuhan Grace New Energy Co., Ltd. is a professional in battery complete experimental equipment, battery testing equipment, and dehumidification and purification equipment. We provides customized solutions for a complete set of lithium battery Laboratory and pilot produce lines, meeting the ... Wuhan Grace New Energy Co., Ltd. is a professional in battery complete experimental equipment, battery testing equipment, and dehumidification and purification equipment. We provides customized solutions for a complete set of lithium battery Laboratory and pilot produce lines, meeting the ...
Get in touch with us
Leave a Message, we will call you back quickly!