Delivery Time | 3-5working days |
Packaging Details | wooden box |
Classification | Flame type(6Lamp Positions) |
Model | BXT-AAS6H |
Detector | Hamamatsu Photomultiplier Tube from Japan |
wavelength range | (190-900)nm |
Wavelength indication error | ≤±0.1nm |
Wavelength repeatability | ≤±0.025nm |
Baseline drift | 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) |
Light source system | Rotary turret-type fully automatic switching lamp holder |
Element lamp Lighting mode | 400Hz, 1/4 duty cycle pulse is on |
Monochromator | Czerny-Turner Enhanced type |
Grating line density | 1800 |
Spectral bandwidth | 0nm、0.1nm、0.2nm、0.4nm、1.0nm、2.0nm Multi-gear automatic switching |
Atomizer | Flame atomizer |
Flame atomization system | Standard equipment |
Burner | 0.5mmx100mmAll-titanium combustion head |
Sprayer | Metal sleeve high-efficiency glass spray nozzle |
Atomization chamber | Corrosion-resistant all-plastic atomization chamber |
Repetition | RSD≤0.7% |
Detection limit | (Cu)<0.006ug/ml |
Safety protection | It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown. |
Sample size | 1-99 |
Result output | Multi-format data storage and print output |
Communication interface | RS232, USB expansion interface |
Host machine size | 1000x400x470mm |
Weight(kg) | 75 |
Brand Name | BAXIT |
Model Number | BXT-AAS6H |
Place of Origin | china |
View Detail Information
Explore similar products
Lab Device Touch Screen FP640 Digital Flame Photometer For K Na Of Agricultural
FP640 Laboratory Touch Screen Flame Photometer Metal Analyzer Na K Flame
7 Inch LCD Touch Screen Flame Spectrophotometer BXT-FP640 In Field Of Agricultur
Digital Flame Spectrometer Lab Flame Photometer For K Na Ca Ba Li Analysis
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000units |
Delivery Time | 3-5working days | Packaging Details | wooden box |
Classification | Flame type(6Lamp Positions) | Model | BXT-AAS6H |
Detector | Hamamatsu Photomultiplier Tube from Japan | wavelength range | (190-900)nm |
Wavelength indication error | ≤±0.1nm | Wavelength repeatability | ≤±0.025nm |
Baseline drift | 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) | Light source system | Rotary turret-type fully automatic switching lamp holder |
Element lamp Lighting mode | 400Hz, 1/4 duty cycle pulse is on | Monochromator | Czerny-Turner Enhanced type |
Grating line density | 1800 | Spectral bandwidth | 0nm、0.1nm、0.2nm、0.4nm、1.0nm、2.0nm Multi-gear automatic switching |
Atomizer | Flame atomizer | Flame atomization system | Standard equipment |
Burner | 0.5mmx100mmAll-titanium combustion head | Sprayer | Metal sleeve high-efficiency glass spray nozzle |
Atomization chamber | Corrosion-resistant all-plastic atomization chamber | Repetition | RSD≤0.7% |
Detection limit | (Cu)<0.006ug/ml | Safety protection | It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown. |
Sample size | 1-99 | Result output | Multi-format data storage and print output |
Communication interface | RS232, USB expansion interface | Host machine size | 1000x400x470mm |
Weight(kg) | 75 | Brand Name | BAXIT |
Model Number | BXT-AAS6H | Place of Origin | china |
Atomic Absorption Spectrophotometer
Atomic absorption spectrophotometer can be widely applied in various industries such
as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental
protection and commodity inspection. The application of it for the analysis of trace and ultra-trace
elements has gradually shifted from inorganic chemistry to organic chemistry in recent years.
Working principle
The characteristic spectral radiation of the element to be measured is emitted by the light
source and absorbed by the ground-state atoms of the element to be measured in the vapor
of the sample produced by the atomizer such as a flame or graphite furnace. The content of
the element to be measured is determined by measuring the amount of the characteristic
spectral radiation absorbed.
Classification | Flame type (4,6,8Lamp Positions) | Flame Graphite Integrated Machine (4,6Lamp Positions) | Fully automatic flame graphite integrated machine (8Lamp Positions) |
Model | BXT-AAS4H BXT-AAS6H BXT-AAS8H | BXT-AAS4HS BXT-AAS6HS | BXT-AAS8HS-P |
Detector | Hamamatsu Photomultiplier Tube from Japan | ||
wavelength range | (190-900)nm | (185-900)nm | |
Wavelength indication error | ≤±0.1nm | ||
Wavelength repeatability | ≤±0.025nm | ||
Baseline drift | 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic) | ||
Light source system | Rotary turret-type fully automatic switching lamp holder | ||
Element lamp Lighting mode | 400Hz, 1/4 duty cycle pulse is on | ||
Monochromator | Czerny-Turner Enhanced type | ||
Grating line density | 1800 | ||
Spectral bandwidth | 0nm,0.1nm,0.2nm,0.4nm,1.0nm,2.0nm Multi-gear automatic switching | ||
Atomizer | Flame atomizer | ||
Flame atomization system | Standard equipment | ||
Burner | 0.5mmx100mmAll-titanium combustion head | ||
Sprayer | Metal sleeve high-efficiency glass spray nozzle | ||
Atomization chamber | Corrosion-resistant all-plastic atomization chamber | ||
Repetition | RSD≤0.7% | ||
Detection limit | (Cu)<0.006ug/ml | ||
Safety protection | It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown. | ||
Graphite Furnace Atomic Absorption System | No | Standard configuration | |
Detection limit | No | 1.5pg | |
Precision | No | ≤3% | |
Heating temperature range | No | Room temperature-3000℃ | |
Heating speed | No | 2000 degrees per second | |
Temperature control accuracy | No | 1% | |
Heating conditions setting | No | 11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system | |
Safety protection | No | Pressure system failure protection, cooling system failure protection, real-time power monitoring | |
Background correction (deuterium lamp) | No | When using 1ABS, the value should be ≥ 60 times. | |
Background correction | No | When using 1ABS, the value should be ≥ 60 times. | |
Automatic sample introduction system | No | 85 channels, automatic calibration curve configuration, automatic dilution function, high-precision injection | |
Sample size | 1-99 | ||
Result output | Multi-format data storage and print output | ||
Communication interface | RS232, USB expansion interface | ||
Host machine size | 1000x400x470mm | 1030x430x400mm | |
Weight(kg) | 75 | 120 | 130 |
Applicable scenarios
Product detail illustration
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller,Other
Year Established:
2012
Total Annual:
10,000,000-20,000,000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Shanghai Glomro Industrial Co., Ltd was founded in 2012. Specializing in the production of thermal analysis machine, laboratory instrument, analytical instrument, testing equipment, industrial measurements and instruments products. Products of high quality, fashiona... Shanghai Glomro Industrial Co., Ltd was founded in 2012. Specializing in the production of thermal analysis machine, laboratory instrument, analytical instrument, testing equipment, industrial measurements and instruments products. Products of high quality, fashiona...
Get in touch with us
Leave a Message, we will call you back quickly!