CertifiCAT-partsion | ISO9001 |
Payment Terms | T/T L/C, 30% deposit,70% before delivery |
Supply Ability | 100 units/ Per month |
Delivery Time | 30 days |
Packaging Details | Open type |
Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Speed | 1500rpm |
Weight | 700kgs |
Rated Current | 90-1800A |
Voltage | 400/230V |
Alternator Model | Stamford or Leroy Somer |
Coolant Volume (L) | 21.0 |
Starting Method | 12V DC electrical start |
Brand Name | GSKA |
Model Number | JP-C160 |
Place of Origin | China |
View Detail Information
Explore similar products
150kVA Genset Diesel Generator , 4 Stroke Perkins 1006TAG
120kw 50Hz Genset Diesel Generator , Perkins 1006TAG
550KVA Cummins Generator Set , 50Hz , 3 Phase , 4-Cycle
Cummins 6CTA8.3-G2 Battery Powered Generator , Air Cooling 100KW
Product Specification
CertifiCAT-partsion | ISO9001 | Payment Terms | T/T L/C, 30% deposit,70% before delivery |
Supply Ability | 100 units/ Per month | Delivery Time | 30 days |
Packaging Details | Open type | Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Speed | 1500rpm | Weight | 700kgs |
Rated Current | 90-1800A | Voltage | 400/230V |
Alternator Model | Stamford or Leroy Somer | Coolant Volume (L) | 21.0 |
Starting Method | 12V DC electrical start | Brand Name | GSKA |
Model Number | JP-C160 | Place of Origin | China |
High Light | Silent Diesel Generator 3KW ,1500rpm Silent Electric Generator |
Silent Electric Generator Set Portable Silent Diesel Generator 3KW-1000KW
Protective type unit:
Protective units are used in outdoor places without special requirements for noise. It is mainly composed of standard unit, protective cover shell, smoke exhaust system and so on. Since the protective cover shell is not set with noise reduction device, as long as it meets the conditions of ventilation and rain and snow prevention, it has a smaller shape volume and a lower cost. Open doors and Windows for ventilation when the unit is in operation. The protective power station can be used in single or multiple parallel connections. The parallel connection of multiple power stations is especially suitable for the occasions where the load varies greatly, the continuous operation reliability is required and the low cost is used economically, such as supporting oil RIGS.
parameter:
Size and type selection - typical load of electrical equipment, expected load of appliCAT-parts-partsion
Electrical factors - Peak load with stability, allowed for appliCAT-parts-partsion
Cooling - Engine cooling during power generation
Ventilation - Airflow allowed during cooling (design)
Fuel storage - How long a generator runs at a specific rate of use
Noise-db levels for specific models
Exhaust - ppm (parts per million) of certain elements, considering the environment and the environment around the generator
Start the system - key start, pull start, button start, etc
Engine Data:
Manufacturer / Model: | DCEC Cummins 6CTA8.3-G2, 4-cycle |
Air Intake System: | Turbo, Water/Air Cooling |
Fuel System: | PB/W type fuel pump |
Cylinder Arrangement: | 6 in line |
Displacement: | 8.3L |
Bore and Stroke: | 114*135(mm) |
Compression Ratio: | 17:1 |
Rated RPM: | 1500rpm |
Max. Standby Power at Rated RPM: | 180KW/244HP |
Governor Type: | Electronic |
Exhaust System | |
Exhaust Gas Flow: | 34.7m3/min |
Exhaust Temperature: | 570℃ |
Max Back Pressure: | 10kPa |
Air Intake System | |
Max Intake Restriction: | 6kPa |
Burning Capacity: | 12.4m3/min |
Air Flow: | 238m3/min |
Fuel System | |
100%( Prime Power) Load: | 215 g/Kw.h |
75%(Prime Power) Load: | 211 g/Kw.h |
50%(Prime Power) Load:: | 216 g/Kw.h |
100%( Prime Power) Load: | 39.7L /h |
Oil System | |
Total Oil Capacity: | 23.8L |
Oil Consumption: | ≤4g/kwh |
Engine Oil Tank Capacity: | 18.9L |
Oil Pressure at Rated RPM: | 276-414kPa |
Cooling System | |
Total Coolant Capacity: | 34L |
Thermostat: | 82-95℃ |
Max Water Temperature: | 104℃ |
Alternator SpecifiCAT-parts-partsion:
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data:
Alternator Data | |
Number of Phase: | 3 |
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude: | ≤1000m |
Exciter Type: | Brushless, self-exciting |
Insulation Class, Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | ≤±1% |
Alternator Capacity: | 182KVA |
Alternator Efficiencies: | 92.4% |
Air Cooling Flow: | 0.514m3/s |
Company Details
Business Type:
Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company
Year Established:
1985
Total Annual:
4Million-5Million
Employee Number:
50~100
Ecer Certification:
Active Member
Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part... Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...
Get in touch with us
Leave a Message, we will call you back quickly!