CertifiCAT-partsion | ISO9001 |
Payment Terms | T/T L/C, 30% deposit,70% before delivery |
Supply Ability | 100 units/ Per month |
Delivery Time | 30 days |
Packaging Details | Open type |
Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Rated Voltage | 400/230V |
Weight | 1320 |
Generator Type | Super Silent.Open.Trailer.Container |
Automatic transfer switch | SmartGen, Deepsea, Comap |
Controller(optional) | Deepsea, Comap, SmartGen |
Engine | Cummins Diesel Engine |
Frequency | 50HZ/60HZ |
Brand Name | Cummins |
Model Number | JP-C1100 |
Place of Origin | Donggaun,china |
View Detail Information
Explore similar products
6CTAA8.3-G2 Cummins Diesel Generators , 160KW / 200KVA
Electronic Cummins Diesel Generators With Water Cooling, standby800KW, 3 phase
Water Cooled Cummins Diesel Generators , 160KW / 200KVA
160KW / 200KVA Cummins Diesel Generators , 6CTAA8.3-G2
Product Specification
CertifiCAT-partsion | ISO9001 | Payment Terms | T/T L/C, 30% deposit,70% before delivery |
Supply Ability | 100 units/ Per month | Delivery Time | 30 days |
Packaging Details | Open type | Port: | HongKong or ShenZhen,ShangHai,Dalian as required |
Rated Voltage | 400/230V | Weight | 1320 |
Generator Type | Super Silent.Open.Trailer.Container | Automatic transfer switch | SmartGen, Deepsea, Comap |
Controller(optional) | Deepsea, Comap, SmartGen | Engine | Cummins Diesel Engine |
Frequency | 50HZ/60HZ | Brand Name | Cummins |
Model Number | JP-C1100 | Place of Origin | Donggaun,china |
High Light | ISO9001 Cummins Diesel Generators ,4BTA3.9-G2 Silent Generator Set ,230V Open Type Genset |
Cummins Diesel Generator 4BTA3.9-G2 Silent Generator Set Open Type Genset
Power calibration:
diesel generator set is a combination of a diesel engine and a synchronous alternator. The maximum power allowed to use diesel engine is limited by the mechanical load and thermal load of parts, so the maximum power allowed to run continuously is called the calibrated power;
Diesel engine can not exceed the calibrated power use, otherwise it will shorten its service life, and may even cause accidents.
According to the national standard, the calibrated power on the diesel nameplate is divided into the following four CAT-parts-partsegories;
1) 15min power: that is, the maximum power allowed to run the diesel engine for 15min. Overload operation may be required in a short time and the calibrated power with acceleration performance is required, such as the calibrated power of diesel engines of automobiles and motorcycles.
2) 1h power: that is, the maximum effective power of the diesel engine allowed to run continuously for 1h. Such as wheeled tractor, locomotive, Marine diesel engine calibration power.
3) 12h power: that is, the maximum effective power of the diesel engine allowed to run continuously for 12h, that is, we often say the rated power. Such as power station unit, engineering machinery with diesel engine calibration power.
4) Continuous power: that is, the maximum power allowed by the diesel engine to run continuously for a long time.
Cummins Technical Parameters(20-60KW) | |||||
Genset | Model | GSKA22S | GSKA33S | GSKA50S | GSKA66S |
Rated Power(KW/KVA) | 20/25 | 30/37 | 45/56 | 60/75 | |
Standby Power(KW/KVA) | 22/27 | 33/41 | 50/62 | 66/82 | |
Rated Current(A) | 36 | 54 | 81 | 108 | |
weight(kg) | 1070 | 1320 | |||
Size(mm) | 1480*710*1120 | 2250*920*1400 | |||
Diesel Engine | Model | 4B3.9-G1 | 4BT3.9-G1 | 4BTA3.9-G2 | 4BTA3.9-G11 |
Manufacturer | DCEC | ||||
Continuous Power(KW) | 24 | 36 | 50 | 70 | |
Standby Power(KW) | 26 | 40 | 55 | 80 | |
Number of Cylinders | 4 | ||||
Cylinder Diameter*Stroke(mm) | 102*120 | ||||
Cylinder Arrangement | In-line | ||||
Compression Ratio | 16.5 | ||||
Displacement(L) | 3.9 | ||||
Intake Type | Exhaust gas turbocharger | ||||
Cooling Type | Tank fan cooling | ||||
Rated Speed(rpm) | 1500 | ||||
Fuel Consumption(g/kwh) | ≤198 | ||||
Discharge Temperature(℃) | 576 | ||||
Unpitched Sound(db) | 98 | ||||
Speed Regulation | Electronic Speed Regulation | ||||
Alternator | Nominal Voltage(V) | 400/230 | |||
Alternator(Optional) | Leroy-Somer, Stamford, Engga, Marathon, Elmaer, Wandi, etc. | ||||
Rated Capacity(KW/KVA) | 20/25 | 30/37 | 45/56 | 60/75 | |
Rated Power Factor | 0.8(lag) | ||||
Exciter Type | Self Excitation Brushless | ||||
Maximum Voltage Adjustment Rate | ±1% | ||||
Phase | Three-phase Four-wire | ||||
Control Panel | Control Cabinet Model | TBZK880 | |||
Controller(Optional) | SmartGen, Deepsea, Comap | ||||
Rated Capacity of Circuit Breaker(A) | 100A |
Company Details
Business Type:
Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company
Year Established:
1985
Total Annual:
4Million-5Million
Employee Number:
50~100
Ecer Certification:
Active Member
Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part... Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...
Get in touch with us
Leave a Message, we will call you back quickly!