China 3 Pole MCCB Perkins Diesel Generator , P250HE 250 kva Genset
China 3 Pole MCCB Perkins Diesel Generator , P250HE 250 kva Genset

  1. China 3 Pole MCCB Perkins Diesel Generator , P250HE 250 kva Genset

3 Pole MCCB Perkins Diesel Generator , P250HE 250 kva Genset

  1. MOQ: 20-30 pieces
  2. Price: Negotiable
  3. Get Latest Price
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month
Port: HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion CE/RoHs/ISO9001
Place of Origin China
Brand Name GSKA
Model Number JP-P250HE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires. Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal Supply Ability 500 pieces per Month
Port: HongKong or ShenZhen,ShangHai,Dalian as required CertifiCAT-partsion CE/RoHs/ISO9001
Place of Origin China Brand Name GSKA
Model Number JP-P250HE
High Light standby diesel generator diesel generators sets

 

1. Standby power:                           200.0 kW

2.Engine Make & Model:        Perkins 1306-E87TA300

3.Alternator Model:                          LL5014H

4.Circuit Breaker Type:                 3 Pole MCCB

5.Class:                                       ISO 8528 G2

6.Compression Ratio:                         16.9:1

7.Displacement: l (cu.in)                 8.7 (530.9) 

8.Bore/Stroke: mm (in)            116.6 (4.6)/135.9 (5.4)

9.Moment of Inertia: kg m² (lb. in²)    1.54 (5266)

10.Dimensions(mm*in) :   2960 (116.5)*1003 (39.5)*1718 (67.6)

 

3 Pole MCCB 250kVA Perkins Diesel Generator , P250HE

Output Ratings

Generating Set Model

*                               P250HE Prime*                     Standby*

380-415V, 50 Hz

                                           230.0 kVA                250.0 kVA

                                           184.0 kW                 200.0 kW

480V, 60 Hz

                                            245.0 kVA                269.0 kVA

                                            196.0 kW                 215.2 kW

  • Refer to ratings definitions on page 4.

           Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 1306-E87TA300

Alternator Model:

LL5014H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                1800

Fuel Tank Capacity: litres (US gal)

350 (92.5)

Fuel Consumption:  P230H    l/hr (US gal/hr)

48.7 (12.9)       55.3 (14.6)

Fuel Consumption:   P250HE   l/hr (US gal/hr)

52.6 (13.9)       61.4 (16.2)

P230H / P250HE

 

Engine Technical Data

 

Physical Data     

 

Manufacturer:                                            Perkins

Model:                                                1306-E87TA300

No. of Cylinders/Alignment:                6 / In Line

Cycle:                                                       4 Stroke

Induction:                          Turbocharged Air To Air Charge Cooled

Cooling Method:                             Water Governing

Type:                                              Electronic Governing

Class:                                                 ISO 8528 G2

Compression Ratio:                             16.9:1

Displacement: l (cu.in)                     8.7 (530.9)

Bore/Stroke: mm (in)                  116.6 (4.6)/135.9 (5.4)

Moment of Inertia: kg m² (lb. in²)      1.54 (5266)

Engine Electrical System:

-Voltage/Ground:                                24/Negative

-Battery Charger Amps:                         45

Weight: kg (lb)

- Dry:                                                   671 (1479)

- Wet:                                                  698 (1539)

 

Air System                                                    50 Hz                                                                            60 Hz

 

Air Filter Type:                         Replaceable Element Combustion

Air Flow:

m³/min (cfm)       

-Standby:                                                  16.9 (597)                                                                     23.5 (830)

-Prime:                                                      17.6 (622)                                                                     24.0 (848)

Max. Combustion Air Intake

Restriction: kPa (in H2O)                        6.2 (24.9)                                                                     6.2 (24.9)

Radiator Cooling Air Flow:

m³/min (cfm)                                       324.0 (11442)                                                               414.0 (14620)

External Restriction to

Cooling Air Flow: Pa (in H2O)                  125 (0.5)                                                                     125 (0.5)

 

 

Cooling System                                           50 Hz                                                                             60 Hz

 

Cooling System Capacity:

l (US gal)                                                  39.8 (10.5)                                                                   39.8 (10.5) 

Water Pump Type:                                                                         Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                               101.3 (5761)                                                                118.6 (6745)

-Prime:                                                     93.8 (5334)                                                                109.2 (6210)

Heat Radiation to Room:

kW (Btu/min)       

-Standby:                                                 58.5 (3327)                                                                   66.8 (3799)

Cooling System Capacity:

l (US gal)                                                  39.8 (10.5)                                                                    39.8 (10.5) 

Water Pump Type:                                                                                  Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                101.3 (5761)                                                               118.6 (6745)

-Prime:                                                      93.8 (5334)                                                               109.2 (6210)

Heat Radiation to Room:

kW (Btu/min)       

-Standby:                                                   58.5 (3327)                                                                66.8 (3799)

 

Performance                                                50 Hz                                                                            60 Hz

 

Engine Speed: RPM                                    1500                                                                            1800

Gross Engine Power: kW (hp)

-Standby:                                                    224.0 (300.0)                                                           242.5 (325.0)

-Prime:                                                        205.5 (276.0)                                                           223.5 (300.0)

BMEP: kPa (psi)

-Standby:                                                  2058.0 (298.5)                                                         1857.0 (269.3)

-Prime:                                                      1888.0 (273.9)                                                         1711.0 (248.2)

Regenerative Power: kW                              20.8                                                                              28.6

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                                       Spin-On, Full Flow

Total Oil Capacity l (US gal):                                    26.4 (7.0)

Oil Pan l (US gal):                                                      22.7 (6.0)

Oil Type:                                                               API CG4 15W-40

Cooling Method:                                                           Water

 

Fuel System:

 

Fuel Filter Type:                                                   Replaceable

Element Recommended Fuel:                     Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110%              100%               75%                50%

Load               Load               Load               Load

P230H

 

Exhaust System                                          50 Hz                                                                            60 Hz

Silencer Type:                                                                                       Level 1

Silencer Model & Qty:                                                  SD100 (1) Pressure Drop Across

Silencer System: kPa (in Hg)                 8.70 (2.569)                                                             8.70 (2.569)

Silencer Noise Reduction

Level: dB                                                         12                                                                                  10

Max. Allowable Back

Pressure: kPa (in. Hg)                            10.7 (3.2)                                                                     10.7 (3.2)

Exhaust Gas Flow:m³/min (cfm)       

-Standby:                                                 44.5 (1572)                                                                 58.1 (2052)

-Prime:                                                     45.9 (1621)                                                                  59.2 (2091)

Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                                     508 (946)                                                                    447 (836)

-Prime:                                                         480 (895)                                                                    431 (808)

50 Hz         52.6 (13.9)      48.7 (12.9)       37.6 (9.9)        26.8 (7.1)

60 Hz         61.4 (16.2)      55.3 (14.6)      41.1 (10.9)       29.3 (7.7)

 

P250HE

 

50 Hz                                52.6 (13.9)      40.4 (10.7)       28.6 (7.6)

60 Hz                                61.4 (16.2)      45.0 (11.9)       31.5 (8.3)

 

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

P230H / P250HE

 

Alternator Performance Data

Data Item

50 Hz                                                            60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V

Motor Starting Capability* kVA

495

465

425

546

543

362

425

397

468

Short Circuit Capacity** %

300

300

300

300

300

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

2.780

 

0.130

 

0.080

3.000

 

0.140

 

0.086

3.320

 

0.160

 

0.095

2.320

 

0.110

 

0.066

2.660

 

0.130

 

0.076

4.210

 

0.200

 

0.121

3.540

 

0.170

 

0.101

3.830

 

0.180

 

0.110

3.170

 

0.150

 

0.091

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data                                                                                                     Operating Data

Manufacturer: FG WILSON

Overspeed: RPM  2250

Model:  LL5014H

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF:50

Insulation Class:  H

Wave Form IEC = THF:  2.0%

Winding Pitch Code:  2/3 - 6

Total Harmonic Content LL/LN:                         4.0%

Wires:12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating:  IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                   17.2 (978)

-60 Hz:                                  18.1 (1029)

Excitation System:  SHUNT

AVR Model:                                                             R448

P230H / P250HE

 

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

 

Voltage         Prime Model                Standby Model          Voltage          Prime Model                Standby Model

                             P230H                         P250HE                                       P230H                         P250HE

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

230.0              184.0

250.0              200.0

480/277V

245.0              196.0

269.0              215.2

400/230V

230.0              184.0

250.0              200.0

220/127V

245.0              196.0

268.0              214.4

380/220V

230.0              184.0

250.0              200.0

380/220V

245.0              196.0

265.0              212.0

230/115V

230.0              184.0

250.0              200.0

240/120V

245.0              196.0

267.0              213.6

220/127V

215.0              172.0

240.0              192.0

230/115V

245.0              196.0

267.0              213.6

220/110V

230.0              184.0

250.0              200.0

440/254V

245.0              196.0

266.0              212.8

200/115V

230.0              184.0

250.0              200.0

220/110V

245.0              196.0

265.0              212.0

 

 

 

208/120V

245.0              196.0

268.0              214.4

 

 

 

230/115V

245.0              196.0

267.0              213.6

 

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


 

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 


 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

Net (+ lube oil)

2100 (4630)

Length

2960 (116.5)

Wet (+ lube oil & coolant)

2137 (4711)

Width

1003 (39.5)

Fuel, lube oil & coolant

2432 (5362)

Height

1718 (67.6)

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

Warranty

All equipment carries full manufacturer's warranty.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company

  • Year Established:

    1985

  • Total Annual:

    4Million-5Million

  • Employee Number:

    50~100

  • Ecer Certification:

    Active Member

  Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...   Since establishment in 1985, Guangdong ALI Testing Equipment Co., Ltd, a wholly-owned subsidiary of GSKA Group has been providing a wide and complete range of products and services to the society. GSKA has now 16 offices, warehouses and service centres in China, with head office loCAT-part...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong ALI Testing Equipment Co,.Ltd
  • No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China
  • https://www.genset-dieselgenerator.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement