Rated Voltage | 230VDC |
Resistive Load Bank | 5KW*6 |
Ambient temperature | -25℃~55℃ |
Protection class | IP23 |
Loading Precision | ± 3% |
Control Methods | Remote control, Computer Control, Local control |
Brand Name | Fullde |
Model Number | FDLB-30KW-230V-J |
Certification | CE, ISO9001 |
Place of Origin | Dongguan,China |
View Detail Information
Explore similar products
500KW Generator Testing Dummy Variable Load Bank With Load Step Control
Indoor / Outdoor Generator Load Bank For Electrical Or Marine Load Testing
Continuous High Power Dummy Load Bank , Load Bank Testing Diesel Generators
Intelligent Stainless Steel Generator Load Bank With Large Load Capacity
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 10 sets per month |
Delivery Time | 25 working days | Packaging Details | Packaged by Wooden Case with Soft Protective Material |
Rated Voltage | 230VDC | Resistive Load Bank | 5KW*6 |
Ambient temperature | -25℃~55℃ | Protection class | IP23 |
Loading Precision | ± 3% | Control Methods | Remote control, Computer Control, Local control |
Brand Name | Fullde | Model Number | FDLB-30KW-230V-J |
Certification | CE, ISO9001 | Place of Origin | Dongguan,China |
High Light | generator dummy load bank ,portable generator load bank |
Product Description and Application
UPS test the main purpose is to identify the actual technical indicators UPS can meet the requirements. UPS testing generally includes two types of dynamic testing and steady-state testing. Steady-state test is to test the input and output phase voltage, line voltage, no-load loss, power factor, efficiency, output voltage waveform, distortion and output voltage under no load, 50% rated load and 100% rated load. And the like. Dynamic testing is generally to test UPS output voltage waveform changes, to test the dynamic characteristics of the UPS and energy feedback path in the load mutation (generally select the load from 0% -100% and from 100% -0%).
Key Features:
Long time empty load or light load may easily lead to the carbon deposition of backup generator unit thus the capacity decreasing and failed start easily occurring.The product can be used for testing performance indicators of data center's generator unit,regularly check,repair and maintain generator unit.It is crucial for data center to guarantee power steady.
Specifications
Technical Parameters | |
Resistive Load Bank | 5KW*6 |
Rated voltage | 230VDC |
Type of Load Bank | Pure Resistive |
Control mode | The circuit breaker is executed |
Working method | Continuous |
Working power supply | The working power is shared with the main circuit power supply |
Cooling method | forced air cooling,horizontal air in, vertical air out |
Ambient temperature | ﹣25℃~55℃ |
Relative humidity | Daily average of not more than 95%, the monthly average of not more than 90% |
Altitude | ≤2500m |
Data Management Software
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
20,000,000-30,000,000
Employee Number:
300~500
Ecer Certification:
Active Member
Company Profile Guangdong Fullde Electrical Technology Co.,Ltd, is the leading manufacturer with more than 11 years experience, which locates in China fashion city – Humen Town, Dongguan city, and near by the High-speed rail station, registered capit... Company Profile Guangdong Fullde Electrical Technology Co.,Ltd, is the leading manufacturer with more than 11 years experience, which locates in China fashion city – Humen Town, Dongguan city, and near by the High-speed rail station, registered capit...
Get in touch with us
Leave a Message, we will call you back quickly!