Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100 Set/Sets per Month |
Delivery Time | 25 working days |
Packaging Details | Packaged by Wooden Case with Soft Protective Material |
Type | Portable |
Certificate | ISO9001:2008 |
Cooling | Forced air cooling |
Casing Dimensions | 1100*1300*1600 |
Power Factor | 0.8-1 |
Brand Name | Fullde |
Model Number | 300KW-400V |
Certification | CE, ISO9001 |
Place of Origin | Dongguan,China |
View Detail Information
Explore similar products
30KW 230V Weatherproof Resistive Load Bank / Dc Load Bank With PC Connection
500KW Generator Testing Dummy Variable Load Bank With Load Step Control
Indoor / Outdoor Generator Load Bank For Electrical Or Marine Load Testing
Continuous High Power Dummy Load Bank , Load Bank Testing Diesel Generators
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100 Set/Sets per Month |
Delivery Time | 25 working days | Packaging Details | Packaged by Wooden Case with Soft Protective Material |
Type | Portable | Certificate | ISO9001:2008 |
Cooling | Forced air cooling | Casing Dimensions | 1100*1300*1600 |
Power Factor | 0.8-1 | Brand Name | Fullde |
Model Number | 300KW-400V | Certification | CE, ISO9001 |
Place of Origin | Dongguan,China | ||
High Light | generator dummy load bank ,portable generator load bank |
3 Phase Movable Smart Resistance 300KW-400V Generator Load Bank
Fullde Power generator intelligent testing system can accurately test the output power and loading capacity of various generator units,test all the electric parameters including dynamic parameters of generator units,and mainly include two parts: testing control and load cabinet,which is used in coordination with host computer thus materializing intelligentization and automatization to complete the testing of all electric parameters of generator unit,meanwhile,charts,curves and testing report are produced,and no manual operation is required(intelligently controlled,manual/automatic may be selected),to provide scientific testing means for large power generator units.
Testing function:
1. Parameter display and measurement:
Control panel contains Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
2. Load bank use premium components to ensure reliable performance and longer service life including:
Switch: ABB, Siemens and Schneider, PLC: Panasonic and Siemens;
3. Vltage and frequency setting testing, fluctuation testing, transient testing functions, can automatically test maximum and minimum,values of voltage,current and frequency as well as restoring time when testing load changes suddenly;
4. May automatically produce various charts, testing reports,can be signed and change the format according to customer's requirments;
5. Testing reports may be inquired, displayed and printed based on time, model, machine number,the minimum resolution time of stable state record is 1s, transient;
6. When testing,the rated power and loading time of generator unit tested may be input,the system will automatically complete the loading test from 0,25%,50%,75%,85%,90%,100%,110%,100%,90%,85%,75%,50%,25%,0 strictly according to the state standard,store and display the changes,restoring time and curve of V,I,KW,Hz of generator when loaded in the form of format and sketch,the tested points may also be configured manually;
7. Load/unload with one key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
Technical Parameters for reference:
System components | Load bank, resistive load,data collection, automatic control and manual control, electrical control, cooling devices and auxiliary control,Industrial machines, printer. |
Total discharge power | 300KW |
Resistive load stalls | step: 5KW |
Test voltage | Three-phase AC400V |
Test Frequency | 50Hz |
Resistance tube | Insulation resistance of each resistor above DC500V 100MΩ , Pressure AC2000V 1 minute, Resistance to high temperature. |
Load connection | Star (three-phase four -wire) |
Loading precision | ±3%; |
Work way | Continuous work |
Working power | 480VAC/50Hz/Three-phase four-wire system; (reservation terminals) |
Operator terminal | IPC / software, full realization of automated control |
Control mode | Manual control / computer software auto control |
Measured Control Function | Load subtraction control, extended load automatic identification synchronization control |
IPC detection function | I, V, HZ, KW, COSΦ etc.Real-time display, electrical performance testing, curves and report output, system electrical parameters monitoring, automatic data acquisition; |
Parameter record | Form through EXCEL, curves pictures saved by WORD document |
Parameter display | three-phase voltage, three- phase current, apparent power, active power, reactive power, power factor, frequency, etc.; |
Load protection | Overvoltage, overcurrent, high temperature, air flow and fan failure protection; |
Fault alarm | Fan failure, load high temperature alarm |
Dimension | 1100*1300*1600 |
Weight | 450kg |
Applicable Scope | For marine diesel generator sets, land diesel generators, power inverters, UPS systems |
Shipping:
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2006
Total Annual:
20,000,000-30,000,000
Employee Number:
300~500
Ecer Certification:
Active Member
Company Profile Guangdong Fullde Electrical Technology Co.,Ltd, is the leading manufacturer with more than 11 years experience, which locates in China fashion city – Humen Town, Dongguan city, and near by the High-speed rail station, registered capit... Company Profile Guangdong Fullde Electrical Technology Co.,Ltd, is the leading manufacturer with more than 11 years experience, which locates in China fashion city – Humen Town, Dongguan city, and near by the High-speed rail station, registered capit...
Get in touch with us