Payment Terms | L/C, D/A, D/P, T/T, MoneyGram |
Supply Ability | 10 sets/month |
Delivery Time | 20-25 days |
Packaging Details | Wooden case |
Product name | Water Treatment System Processing Reverse Osmosis Plant |
Material | FRP or SUS304 |
Capacity | 5000LPH |
Warranty | 1 Year |
Type | RO |
RO membrane's desalting rate | 99% |
Voltage | 380V 3PH 50HZ |
Condition | New |
Brand Name | FILLPACK |
Model Number | RO-5000 |
Certification | CE,ISO |
Place of Origin | ZhangJiaGang City, JiangSu Province, China |
View Detail Information
Explore similar products
Stainless Steel 304 20tph Borehole Drinking Ro Water Filter Plant Machine
Sus304 Auto Operation Valve Drinking 4000lph Ro Water Treatment Machine
500LPH RO Water Treatment Filter Machine With 4040 Membrane
Drinkable 3000lph Reverse Osmosis Water Treatment Machine FRP Filter Tank
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, MoneyGram | Supply Ability | 10 sets/month |
Delivery Time | 20-25 days | Packaging Details | Wooden case |
Product name | Water Treatment System Processing Reverse Osmosis Plant | Material | FRP or SUS304 |
Capacity | 5000LPH | Warranty | 1 Year |
Type | RO | RO membrane's desalting rate | 99% |
Voltage | 380V 3PH 50HZ | Condition | New |
Brand Name | FILLPACK | Model Number | RO-5000 |
Certification | CE,ISO | Place of Origin | ZhangJiaGang City, JiangSu Province, China |
High Light | 5t/h reverse osmosis water treatment machine ,5t/h ro water treatment machine ,380v reverse osmosis water treatment machine |
5T/H reverse osmosis drinking pure water treatment machine / equipment / plant / machine / system / line
5T/H reverse osmosis drinking pure water treatment machine
1. Running continuously, product water quality stability.
2. Don't need to use acid-base regeneration.
3. It's be closing down because of regeneration.
4. Saving backswing and cleaning water.
5. It has high productivity.
6. Without regeneration waste water, don't need waste water treatment device.
7. Save factory space.
8. The pure water treatment machine arrives at food grade and up to the CE, ISO, SGS standard.
The FAQ of pure water treatment machine
Q1: How often the pure water treatment machine should be washed?
A1: Generally, when the standardized flux decrease 10%~15%, or the system desalinization rate decrease 10%~15%, or the operation pressure or section pressure differences increase 10%~15%, the pure water treatment machine should be washed. Washing times is related to system preprocessing, when SDI15<3, the washing frequency is around 4 times/year; when the SDI15 is around 5, may be the washing frequency is 1 times than SDI15<3, but the washing frequency is also depend on the actual situation.
Q2: What is SDI?
A2: It is used to evaluate the colloid contamination possibility of RO system.
Q3: Which should be choice between RO treatment and ion exchanger treatment in general situation?
A3: Both RO treatment and ion exchanger treatment can be adopted. Base on economic conditions, generally, if the saltness is highre, the RO treatment is much substantial. If the saltness is lower, the ion exchanger is much substantial. Now, because the RO technology is widespread, more and more people adopt RO treatment+ion exchanger.
Q4: How long dose one RO membrane can be used?
A4: Generally, one membrane can be used for 5 years. On the other hand, the membrane life time is depend on the chemical stability of membrane, physical stability of components, cleanable, raw water source, preprocessing, washing frequency, operation and management and so on.
Q5: How about the membrane separation ability?
A5: RO technology is the most precision liquid filter technology. RO membrane can intercept inorganic molecule and molecule that dimension larger than 100. On the other hand, hydrone can permeate membrane freely.
Q6: What is the Max. silicon dioxide concentration can be allowed in raw water?
A6: The Max. silicon dioxide concentration is depend on temperature, PH and antisludging agent. When the antisludging agent isn't add, the Max. is 100ppm on concentration water side.
Q7: What kind of preform need before water flow into RO?
A7: The particle and suspended solids can be avoided through sand filter, carbon filter, ion exchanger, and precision filter. In order to the particle damage the HP pump blade and membrane components.
Q8: Could the membrane avoid virus and germ?
A8: The membrane has very high removal rate, at least 3log. Of course, the other components, detection and maintenance way are also importance steps, it can't depend on RO membrane completely.
Q9: Could temperature influence water yield?
A9: The temperature is higher, the water yield is more, vice versa; when the temperature become higher, the pressure should be turn down, vice versa.
Reverse osmosis is a kind of reverse migration movement, with the aid of semipermeable membrane separate the solute and solvent under pressure. Using RO technology to avoid inorganic ion, germ, virus, organics, colloid and so on in raw water.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2010
Total Annual:
2000000USD-2500000
Employee Number:
20~30
Ecer Certification:
Verified Supplier
ZhangJiaGang City FILL-PACK Machinery Co.,Ltd. is located in Jiangsu Zhangjiagang,which dedicated to technology research,manufacture and sales.Since the establishment,we always keep engaging in gallon filling field. Mainly provide the gallon bottles whole factory planning, from preform design to bot... ZhangJiaGang City FILL-PACK Machinery Co.,Ltd. is located in Jiangsu Zhangjiagang,which dedicated to technology research,manufacture and sales.Since the establishment,we always keep engaging in gallon filling field. Mainly provide the gallon bottles whole factory planning, from preform design to bot...
Get in touch with us
Leave a Message, we will call you back quickly!