Payment Terms | D/P, T/T,Paypal, Western Union |
Supply Ability | 1000000PCS/Month |
Delivery Time | 5-7 Days |
Packaging Details | 100PCS/Bag |
Rated Current | 5A to 50A |
Rated Voltage | 12-28V DC |
Reset Type | Modified Reset |
Number of Poles | Single Pole, Normal Closed |
Cabinet | Metal |
Mounting | Stud Mount, Vertical or Horizontal Bracket Mount |
Function Type | Thermal Trip |
Termination | 10-32 Thread |
Packing | PE bag |
Application | Overload Protector |
Brand Name | Tian Rui |
Model Number | E5 Series |
Certification | ROHS |
Place of Origin | China |
View Detail Information
Explore similar products
1A - 100A DC Short Circuit Protection Hydraulic Magnetic Circuit Breaker 125V
200 250 300AMP Waterproof Circuit Breakers For Boat Marine RV Caravan Battery
HD Series Electromagnetic Overload Protector Hydromagnetic Hydraulic Magnetic
RV Yacht Truck Car Battery Power Switch Anti Leakage Protection 200A 300A
Product Specification
Payment Terms | D/P, T/T,Paypal, Western Union | Supply Ability | 1000000PCS/Month |
Delivery Time | 5-7 Days | Packaging Details | 100PCS/Bag |
Rated Current | 5A to 50A | Rated Voltage | 12-28V DC |
Reset Type | Modified Reset | Number of Poles | Single Pole, Normal Closed |
Cabinet | Metal | Mounting | Stud Mount, Vertical or Horizontal Bracket Mount |
Function Type | Thermal Trip | Termination | 10-32 Thread |
Packing | PE bag | Application | Overload Protector |
Brand Name | Tian Rui | Model Number | E5 Series |
Certification | ROHS | Place of Origin | China |
High Light | 50A Battery Circuit Breaker ,Modified Reset Battery Circuit Breaker ,24V Automotive Circuit Breakers |
12V 24V Marine Boat Overload Protector Automatic Reset Waterproof Battery Circuit Breaker with Red Cover
Overcurrent circuit breaker with bi-metal structures, when the circuit is overload, can achieve rapid power off protection function.
E5 Series Waterproof Overload Protector Circuit Breaker with Red Cover
Function Type | Thermal Trip-free,Cycling |
Number of Poles | Single Pole , Normal Closed |
Current &Voltage Ratings | 5-50A,12-28Vdc |
Calibration@25C | 100% Hold , 135% Trip (percent of rating) |
Interrupting Capacity | Branch Circuit Protection: 2,500A @12Vdc |
Termination | #10- 32 Thread and Quick-Connect options available |
Mounting | Stud Mount or Bracket Mount |
Compliances | SAE J553;SAE J1171(Ignition Protected) |
Specifications of Waterproof Overload Protector Circuit Breaker with Red Cover
Single Pole Thermal Type Breakers
Applications: Typically used in Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Rating: 5-50A, 14VDC; 28VDC (Series E51, E53).
Interrupt Rating: Main Circuit Protection: 1.5kA @ 12VDC (Series E51 E53 );
Branch Circuit Protection: 2.5kA @ 12VDC (Series E51 sealed & Series E53 plastic cover).
Operating Temperature Rating: –40°F (–40°C) to 185°F (85°C)
Storage Temperature Rating: –40°F (–40°C) to 260°F (125°C)
Materials: Black UL-Rated thermoplastic body (thermoset for Type II body & buttons). Cover is grey
thermoplastic or steel-Type l gold, Type ll silver
Marking: Standard marking includes amp ratings and part numbers. Custom markings also available.
Termination: #10-32 thread and quick-connect options available
Torque Rating: 24 in-lbs (2 7N•m) max
Mounting Torque Rating: Plastic cover in-lbs (1 7N•m) . Metal cover 30 in-lbs (3 4N•m).
Ingress Protection Rating: IP66 On plastic cover version only (except for terminals)
Compliances: SAE J553; SAE J1171 ((consult factory for Ignition Protection ratings))
Dimension of Waterproof Overload Protector Circuit Breaker with Red Cover
Wiring of Waterproof Overload Protector Circuit Breaker with Red Cover
Six way wiring diagram:
360° wiring design, easy and quicker to install
Temperature Degrating Curves of Waterproof Overload Protector Circuit Breaker with Red Cover
Application of Waterproof Overload Protector Circuit Breaker with Red Cover
Transportation equipment, marine, medical, and other power
supplies:
1.Circuit breaker can do is protect the circuit from a high current short circuit.
2.Through its thermal trip it can protect the circuit from overload conditions. A circuit breaker will trip if too large a draw or current flow occurs across a thermal shunt inside.
3.Easy for mounting.
4.Trip-off time is customizing and adjustable according to customers' demands.
5.The design allows the thermal circuit breaker to be extremely cost-effective while remaining durable and reliable.
Contact Details:
Andy Wu
Email: andy@tianrui-fuse.com.cn
MP/Whatsapp: +86 13532772961
Wechat: HFeng0805
Skype: andywutechrich
QQ: 969828363
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
9000000-9500000
Employee Number:
150~150
Ecer Certification:
Verified Supplier
Dongguan Tianrui Electronics Co., Ltd. was founded in 2010. It covers an area of 4,000 square meters and has a monthly production capacity of 50 million pieces. We are committed to be a comprehensive circuit protection component manufacturer and solution supplier. We are specialized in the design, d... Dongguan Tianrui Electronics Co., Ltd. was founded in 2010. It covers an area of 4,000 square meters and has a monthly production capacity of 50 million pieces. We are committed to be a comprehensive circuit protection component manufacturer and solution supplier. We are specialized in the design, d...
Get in touch with us
Leave a Message, we will call you back quickly!