Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 30000 Sets Per Month |
Delivery Time | 1~7days |
Packaging Details | Carton Box /Woody Box |
Product Name | Inverter Brake Unit |
Voltage | 220v 380v 440 |
Frequency | 50Hz 60Hz |
Temperature | -55℃ to +155℃ |
Warranty | 36 Months |
Place Of Origin | Shenzhen China |
Brand Name | K-EASY |
Model Number | Inverter brake unit |
Certification | CE And ISO Certificated |
Place of Origin | China |
View Detail Information
Explore similar products
Stable Fireproof Inverter Brake Unit Dynamic 22KW-75KW 3 Phase
50Hz 60Hz Inverter Brake Resistor , Durable Inverter Braking Chopper Unit
90KW 440V Dynamic Inverter Brake Unit Multipurpose Practical
Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 30000 Sets Per Month |
Delivery Time | 1~7days | Packaging Details | Carton Box /Woody Box |
Product Name | Inverter Brake Unit | Voltage | 220v 380v 440 |
Frequency | 50Hz 60Hz | Temperature | -55℃ to +155℃ |
Warranty | 36 Months | Place Of Origin | Shenzhen China |
Brand Name | K-EASY | Model Number | Inverter brake unit |
Certification | CE And ISO Certificated | Place of Origin | China |
High Light | 50Hz Inverter Brake Unit ,60Hz Inverter Brake Unit ,Practical Braking Resistor Inverter |
Product Type | Rated Current(A) | Crest Current | Minimum Resistance | Size(mm) | Terminals | Drawing Number | ||||
L | L1 | W | W1 | H | ||||||
CDBR-2015 | 15A | 50A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | Figure 1 |
CDBR-2022 | 25A | 75A | 6.8Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-2030 | 30A | 85A | 5Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4030 | 15A | 50A | 20Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4045 | 25A | 75A | 13.6Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4055 | 30A | 85A | 12Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075M | 35A | 100A | 10Ω | 240 | 228 | 85 | 55 | 153 | M4 | |
CDBR-4075 | 35A | 100A | 8Ω | 320 | 304 | 187 | 120 | 163 | M6 | Figure 2 |
CDBR-4110 | 50A | 150A | 6.8Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4160 | 70A | 200A | 5Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4220 | 85A | 300A | 3.3Ω | 320 | 304 | 187 | 120 | 163 | M6 | |
CDBR-4300 | 120A | 400A | 2.5Ω | 320 | 223 | 193 | 304 | 160 | M6 |
In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.
The installation process for an inverter breaker unit can vary depending on the specific unit and the application. However, here are some general steps that can guide you through the process:
Note: This is a general guide, and the specific installation process may vary depending on the unit and application. It is important to follow the manufacturer's instructions and local electrical codes. If you are not familiar with electrical work, it is recommended to seek the assistance of a licensed electrician.
Read the manufacturer's instructions carefully: Before starting the installation, read the manufacturer's instructions and safety precautions carefully. Make sure that you understand the installation process, the wiring requirements, and any other important details.
Choose a suitable location: Choose a location that is suitable for the inverter breaker unit. It should be in a cool, dry, and well-ventilated area, away from direct sunlight, dust, and other contaminants.
Mount the unit: Mount the inverter breaker unit on a suitable surface using appropriate mounting hardware. Make sure that the unit is secure and that there is enough clearance around it for proper ventilation.
Connect the power supply: Connect the power supply wires to the appropriate terminals on the unit. The power supply wires should be sized according to the manufacturer's recommendations and local electrical codes.
Connect the load: Connect the load wires to the appropriate terminals on the unit. Again, the load wires should be sized according to the manufacturer's recommendations and local electrical codes.
Connect the control wires: Connect the control wires to the appropriate terminals on the unit. These wires will be used to control the operation of the inverter breaker unit, such as turning it on and off or adjusting the speed.
Test the unit: Once the installation is complete, test the inverter breaker unit to make sure that it is working properly. Follow the manufacturer's instructions for testing and commissioning the unit.
Maintenance: Regular maintenance of the inverter breaker unit is essential to ensure its continued safe and reliable operation. Follow the manufacturer's instructions for maintenance and inspection of the unit.
Company Details
Business Type:
Manufacturer
Year Established:
2017
Total Annual:
100000000-150000000
Employee Number:
200~280
Ecer Certification:
Active Member
Who We Are Shenzhen K-Easy Automation Co.,Limited. a Professional AC drive, Frequency Inverter, VFD, enterprise which has been specializing in Researching, Manufacturing and Trading high, medium and low voltage frequency inverter, providing our clients with integrated system solutio... Who We Are Shenzhen K-Easy Automation Co.,Limited. a Professional AC drive, Frequency Inverter, VFD, enterprise which has been specializing in Researching, Manufacturing and Trading high, medium and low voltage frequency inverter, providing our clients with integrated system solutio...
Get in touch with us