China factories

China factory - Shenzhen K-Easy Electrical Automation Company Limited

Shenzhen K-Easy Electrical Automation Company Limited

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V

  1. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
  2. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
  3. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
  4. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
  5. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V
  6. China Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V

Three Phase 3Ph Dynamic Braking Unit Inverter 400V 220V 380V

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 30000 Sets Per Month
Delivery Time 1~7days
Packaging Details Carton Box /Woody Box
Product Name Inverter Brake Unit
Voltage 220v 380v 440
Frequency 50Hz 60Hz
Temperature -55℃ to +155℃
Warranty 36 Months
Place Of Origin Shenzhen China
Brand Name K-EASY
Model Number Inverter brake unit
Certification CE And ISO Certificated
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 30000 Sets Per Month
Delivery Time 1~7days Packaging Details Carton Box /Woody Box
Product Name Inverter Brake Unit Voltage 220v 380v 440
Frequency 50Hz 60Hz Temperature -55℃ to +155℃
Warranty 36 Months Place Of Origin Shenzhen China
Brand Name K-EASY Model Number Inverter brake unit
Certification CE And ISO Certificated Place of Origin China
High Light Three Phase Dynamic Braking Unit Inverter3Ph Dynamic Braking Unit Inverter400V Braking Resistor Inverter

K-Drive braking unit use for any 400V 3 ph Inverter 220V 380V single phase Three Phase

 

Brand: K-Drive
Certificate: CE, RoHS

 

 

 
Product Type Rated Current(A) Crest Current Minimum Resistance Size(mm) Terminals Drawing Number
L L1 W W1 H
CDBR-2015 15A 50A 10Ω 240 228 85 55 153 M4 Figure 1
CDBR-2022 25A 75A 6.8Ω 240 228 85 55 153 M4
CDBR-2030 30A 85A 240 228 85 55 153 M4
CDBR-4030 15A 50A 20Ω 240 228 85 55 153 M4
CDBR-4045 25A 75A 13.6Ω 240 228 85 55 153 M4
CDBR-4055 30A 85A 12Ω 240 228 85 55 153 M4
CDBR-4075M 35A 100A 10Ω 240 228 85 55 153 M4
CDBR-4075 35A 100A 320 304 187 120 163 M6 Figure 2
CDBR-4110 50A 150A 6.8Ω 320 304 187 120 163 M6
CDBR-4160 70A 200A 320 304 187 120 163 M6
CDBR-4220 85A 300A 3.3Ω 320 304 187 120 163 M6
CDBR-4300 120A 400A 2.5Ω 320 223 193 304 160 M6

 

 

 

 

 

 

 

Production

In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.

 

 

 

 

 

 

How to maintenace inverter braker unit ?

Maintenance of an inverter breaker unit typically involves the following steps:

  1. Inspect the unit regularly for signs of wear and tear, such as cracks, corrosion, or loose connections. Ensure that all screws and bolts are tight, and that the unit is clean and free of debris.

  2. Check the air filters regularly and clean or replace them as needed. Dirty air filters can reduce the unit's efficiency and increase the risk of damage.

  3. Check the cooling system for leaks or blockages, and ensure that the coolant level is sufficient. Overheating can cause serious damage to the inverter breaker unit.

  4. Inspect the wiring and connections for signs of damage or corrosion. Tighten any loose connections and replace damaged wiring as needed.

  5. Test the unit's performance regularly, using appropriate testing equipment. This can help detect any potential issues before they cause serious damage or failure.

  6. Follow the manufacturer's recommended maintenance schedule and procedures. This may include tasks such as lubrication, cleaning, or component replacement.

  7. Consult with a qualified technician or electrician if you are unsure about any aspect of maintenance or repair. Inverter breaker units can be dangerous to work with, and proper training and expertise are essential for safe and effective maintenance.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2017

  • Total Annual:

    100000000-150000000

  • Employee Number:

    200~280

  • Ecer Certification:

    Active Member

  Who We Are Shenzhen K-Easy Automation Co.,Limited. a Professional AC drive, Frequency Inverter, VFD, enterprise which has been specializing in Researching, Manufacturing and Trading high, medium and low voltage frequency inverter, providing our clients with integrated system solutio...   Who We Are Shenzhen K-Easy Automation Co.,Limited. a Professional AC drive, Frequency Inverter, VFD, enterprise which has been specializing in Researching, Manufacturing and Trading high, medium and low voltage frequency inverter, providing our clients with integrated system solutio...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen K-Easy Electrical Automation Company Limited
  • Wisdom Lmgyu, baishixia community, Fuyong street, Bao 'an District, Shenzhen, China
  • https://www.frequenceinverter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement