China factories

China factory - Forsentek Co., Limited

Forsentek Co., Limited

  • China,Shenzhen ,Guangdong
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg
China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

  1. China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg
  2. China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg
  3. China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg
  4. China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg
  5. China Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

  1. MOQ: 5pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T,Western Union or Paypal
Supply Ability 8860pcs/month
Delivery Time 3~25 working days
Packaging Details Carton
Usage Weight measurement sensor
Type Small single point load cell
Output Analog Transducer
Capacity 0.5kg 1kg 2kg 5kg 10kg 20kg
Feature Off-center load cell
Brand Name Forsentek
Model Number FH02
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,Western Union or Paypal Supply Ability 8860pcs/month
Delivery Time 3~25 working days Packaging Details Carton
Usage Weight measurement sensor Type Small single point load cell
Output Analog Transducer Capacity 0.5kg 1kg 2kg 5kg 10kg 20kg
Feature Off-center load cell Brand Name Forsentek
Model Number FH02 Certification CE
Place of Origin China

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

Small size Single Point Load Cell Sensor FH02 is made of aluminum alloy based on strain gauge technology.Weight transducer FH02 offers 0.5kg / 1kg / 2kg / 3kg / 5kg / 6kg / 10kg / 15kg / 20kg nine rated capacities to choose from. Small Weight Sensor FH02 is temperature compensated to deliver stable readout throughout the working temperature range. Single point load cell transducer FH02 is corner trimmed for platform sizes up to 120x120mm, suitable for off-center load measurement.Beam loadcell FH02 is widely used for bench scales, weight monitoring laboratory equipment, home appliances, dosing machines and other weighing applications. Custom made service is available at Forsentek if the current specifications are not applicable.

2kg single point load cell 1kg
Dimensions
small single point load cell 2kg
Specifications

Rated capacity

0.5kg / 5N / 1.1 lb

1kg / 10N / 2.2lbf

2kg / 20N / 4.4 lb

3kg / 30N / 6.6 lbf

5kg / 50N / 11 lb

6kg / 60N / 13 lbf

10kg / 100N / 22 lb

15kg / 150N / 33 lbf

20kg / 200N / 44 lb

Rated output

0.5kg @ 1.0mV/V
1kg-20kg @ 2.0mV/V

Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.02% of the full capacity
Hysteresis ±0.02% of the full capacity
Nonrepeatability ±0.02% of the full capacity
Creep(5min) ±0.02% of the full capacity
Safe overload 150% of the full scale
Ultimate overload 200% of the full scale
Compensated temperature 0...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.03% R.O./10oC
Temperature shift span ±0.03% R.O./10oC
Input resistance 410±30 ohms
Output resistance 350±10 ohms
Insulation resistance >5000M ohms
Ingress protection IP65
Material of element Aluminum alloy
Cable Ø3*400mm 4-core
Wiring code Red--Excitation+ Black--Excitation-
Green--Signal+ White--Signal-


A load sensor is a transducer that converts mechanical force into electrical signal which is proportional to the weight(or force) being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV.Overloading is the most common cause of loadcell failure, a load cell is just like a spring in certain aspects, which will be damaged if overstretched. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The gap distance can be determined by loading the sensor with rated capacity,then adjust the meachnical stop to reach the bottom of the transducer.In most cases,the load cell will be used to measure load at 30-60% of the full scale,thus the gap distance can also be adjusted using reference load a little higher than the target load to be measured instead of the rated capacity.

small single point load cell with overload protection

Small Single Point Load Cell 1kg Single Point Loadcell Sensor 2kg

1kg single point load cell 2kg

Click here to download datasheet

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2008

  • Total Annual:

    7000000-9000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Site Member

Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ... Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ...

+ Read More

Get in touch with us

  • Reach Us
  • Forsentek Co., Limited
  • 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000
  • https://www.forsensor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement