Payment Terms | T/T,Western Union or Paypal |
Supply Ability | 2880pcs/month |
Delivery Time | 3~25 working days |
Packaging Details | Carton |
Usage | Force measurement |
Capacity | 10N 20N 50N 100N 200N 500N 1KN 2KN |
Type | Miniature compression load cell |
Output | Analog Sensor |
Structure | Column Load Cell |
Brand Name | Forsentek |
Model Number | FCFK |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Low Profile Button Load Cell 1KN 2KN 5KN 10KN 20KN 50KN 100KN Compression Force
Micro compression load cell force sensor 5kg 10kg 20kg 50kg 100kg
Button Load Cell 150kN 100kN 50kN 20kN 10kN 5kN 2kN Compression Force Sensor
Pedal force load cell pedal force transducer 500N 1000N 2000N
Product Specification
Payment Terms | T/T,Western Union or Paypal | Supply Ability | 2880pcs/month |
Delivery Time | 3~25 working days | Packaging Details | Carton |
Usage | Force measurement | Capacity | 10N 20N 50N 100N 200N 500N 1KN 2KN |
Type | Miniature compression load cell | Output | Analog Sensor |
Structure | Column Load Cell | Brand Name | Forsentek |
Model Number | FCFK | Certification | CE |
Place of Origin | China |
Micro Compression Load Cell 10N 20N 50N 100N 200N 500N 1KN 2KN Miniature Force Sensor
Miniature Compression Load Cell FCFK is made of stainless steel based on strain gauge technology to deliver maximum 0.3% non-linearity of the rated capacity.Small size flat load cell FCFK offers 0-10N / 0-20N / 0-50N / 0-100N / 0-200N / 0-500N / 0-1kN / 0-2kN eight measuring ranges to choose from, flange to flange mounting,compact design, you may find micro force transducer FCFK applicable for compression force measurement applications where mounting space is limited, such as mold clamping force measurement, assembly force monitoring, force distribution test,etc..Model FCFK can be modified or customized as per client's request.
Dimensions(in milimeter)
Ordering code | Measurement Range | Force direction |
FCFK-10N | 0-10N / 0-2.2lb | Compression |
FCFK-20N | 0-20N / 0-4.4lb | |
FCFK-50N | 0-50N / 0-0-10lb | |
FCFK-100N | 0-100N / 0-20lb | |
FCFK-200N | 0-200N / 0-45lb | |
FCFK-500N | 0-500N / 0-112lbf | |
FCFK-1kN | 0-1000N / 0-225lbs | |
FCFK-2kN | 0-2000N / 0-450lbf |
Specifications
Capacity | 1kg / 2kg / 5kg / 10kg / 20kg / 50kg / 100kg / 200kg 2.2lb / 4.4lb / 11lb / 22lb / 45lb / 112lb / 225lbf / 450lbs |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.3% R.O. |
Hysteresis | ±0.3% R.O. |
Nonrepeatability | ±0.1% R.O. |
Creep(5min) | ±0.1% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.03% R.O./oC |
Temperature shift span | ±0.03% R.O./oC |
Input resistance | 385±50 ohms |
Output resistance | 350±5 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP50 |
Material of element | Stainless steel |
Cable | Ø2*3000mm 4-core shielded |
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: Micro Load Cell FCFK-100N with 2.0mV/V sensitivity powered by 3.3V DC,the output range is 0...+6.6mV.
Example two: Miniature Load Cell FCFK-50N with 2.0mV/V sensitivity powered by 5V DC,the output range is 0...+10mV.
A signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.
Example: FCFK-200N working with amplifier FSC(0-10V)-24V, the Force-Voltage relationship will be 0-200N compression force VS 0-10V output, 1V voltage corresponds to 20N load, 2V voltage corresponds to 40N force,and so on.
Miniature Compression Load Cell 10N 20N 50N 100N 200N 500N 1KN 2KN Micro Force Transducer
Click here to download datasheet
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2008
Total Annual:
7000000-9000000
Employee Number:
100~150
Ecer Certification:
Site Member
Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ... Located in China,Forsentek Co., Limited has provided load cells,force sensors and measuring solutions to more than 30 countries all over the world. At Forsentek,you can find universal products like: Compression load cell Force sensor force transducer Button load cell Micro load cell ...
Get in touch with us
Leave a Message, we will call you back quickly!