Payment Terms | L/C, , D/P, T/T, Western Union, Paypal, Credit card |
Supply Ability | 200 sets per week |
Delivery Time | 10-15 working days after payment or receipt of L/C |
Packaging Details | Plywood case |
Max length of detecting tube | 25m |
Capacity | 42kg |
Actuation | Automatic |
Pattern of extinguishing | Enclosed flooding |
application | server cabinet |
Brand Name | xingjin |
Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
Place of Origin | China |
View Detail Information
Explore similar products
3Kg Fm200 Fire Extinguisher Tube With GB25972-2010 Standard
42kg Co2 Fire Extinguishing Devices Fire Detection Tube Of Indirect Type: 0-49℃,
Co2 Direct Type Fire Extinguisher Tube 12.1Mpa Max Working Pressure
Carbon Dioxide Fire Detecting Extinguisher Professional Manufacturers Direct
Product Specification
Payment Terms | L/C, , D/P, T/T, Western Union, Paypal, Credit card | Supply Ability | 200 sets per week |
Delivery Time | 10-15 working days after payment or receipt of L/C | Packaging Details | Plywood case |
Max length of detecting tube | 25m | Capacity | 42kg |
Actuation | Automatic | Pattern of extinguishing | Enclosed flooding |
application | server cabinet | Brand Name | xingjin |
Certification | CAL,CMA,CNAS,ILAC-MRA,CCC | Place of Origin | China |
High Light | fire detection tubing ,fire extinguisher tube |
Indirect Or Direct Type Standard Qualify Fm200 Fire Suppression System For Equipment Cabinet
Description
Fm200 fire trace suppression system is a kind of easy and highly dependable fire suppression system. This system is a little bit different from other fm200 fire suppression systems because it doesn’t need those electrical elements to help it be a complete system.
There is a warning device, whose function is equal to the electrical elements, on the top of the fire trace suppression system. No matter the direct type or the indirect type, the compositions are the same except the detecting tube part. For the direct type, there is only one soft pipe but plays two roles that the detecting tube and discharge pipe. For the indirect type, there are one detecting soft pipe and one tough pipe for discharging agent.
Components
The direct type fire detecting tube fire suppression system is consist of a cylinder, an at most 25m long fire detecting tube, a container valve and two kinds of agents-- co2 and fm200.
The indirect type fire detecting tube fire suppression system has the same components as the direct type except a release tube added. In this system, the fire detecting tube is used for just detecting function, so it needs a release tube together, however, for the direct type, the fire detecting tube can be used for both detecting and releasing.
Parameter
NO. | Type of Device | Direct Type Fire Detecting Tube Co2 Fire Suppression Device | Indirect Type Fire Detecting Tube Co2 Fire Suppression Device | Direct Type Fire Detecting Tube FM200 Fire Suppression Device |
1 | Storage Pressure(20℃) | 5.17Mpa | 5.17Mpa | 2.5Mpa |
2 | Max. Working Pressure | 12.1Mpa | 12.1Mpa | 4.2Mpa |
3 | Min. Agent Needed for A Unit | 2.5kg/m3 | 1.5kg/m3 | 0.7kg/m3 |
4 | Max. Length of Fire Tube | 25m | 25m | 20m |
5 | Max. Length of Release Tube | -- | 12m | -- |
6 | Max. Filling Ratio | 0.6kg/L | 0.6kg/L | 1.12kg/L |
The fire detecting tube fire suppression device has the following advantages:
1/ Convenient installation and transportation. Because this system combines fire fighting and alarm function together, and no needs to match electrical elements and pipe fittings, so after fixing the cylinder on a place, all left to do is fixing the detecting tube around a potential source of fire.
2/ Non-electric start mode. It doesn’t need the power to activate the system. This system’s work principle is using its own storage pressure instead of relying on the outside force activating. When the detecting tube is broken by the fire, the agent will discharge.
3/ Little occupation of space. This system is suitable for protecting a system, like telecommunication system, rather than a protected zone. The cylinder fixes on the outer cabinet, and will not occupy many places.
Working procedure
Indirect type: the fire burns the detecting tube → the warning system makes some noises to attract people’s attention → the container valve opens and the agent goes through the discharge pipe because of the pressure’s change → agent sprays out and puts out the fire.
Direct type: the fire burns the detecting tube → the warning system rings and the fire agent goes through the detecting tube → reaches the place that is on fire and sprays out to put out the fire.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
>50000
Employee Number:
>100
Ecer Certification:
Verified Supplier
GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments. Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located... GUANGZHOU XINGJIN FIRE EQUIPMENT CO., LTD. is a professional manufacturer of making and installing fm200 fire suppression system and other fire fighting equipments. Guangzhou Xingjin Fire Equipment Co., Ltd., surrounded by convenient transportation and beautiful environment, is located...
Get in touch with us
Leave a Message, we will call you back quickly!