China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China TDLAS200 Wide-Temperature Range Methane Gas Detection Module
China TDLAS200 Wide-Temperature Range Methane Gas Detection Module

  1. China TDLAS200 Wide-Temperature Range Methane Gas Detection Module
  2. China TDLAS200 Wide-Temperature Range Methane Gas Detection Module
  3. China TDLAS200 Wide-Temperature Range Methane Gas Detection Module

TDLAS200 Wide-Temperature Range Methane Gas Detection Module

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Product model TDLAS200
Detection object Methane (CH4)
Measurement principle Laser absorption spectrum (TDLAS)
Volume 53ml
Fastest response time 0.1s
Measurement range 0~5000ppm
Brand Name KACISE
Model Number TDLAS200
Certification CE
Place of Origin china

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Product model TDLAS200 Detection object Methane (CH4)
Measurement principle Laser absorption spectrum (TDLAS) Volume 53ml
Fastest response time 0.1s Measurement range 0~5000ppm
Brand Name KACISE Model Number TDLAS200
Certification CE Place of Origin china
High Light Methane Gas Detection ModuleTDLAS200 Methane Gas Detection Module

TDLAS200 Wide-Temperature Range Methane Gas Detection Module

 

1.Introduction

 

The KACISE TDLAS200 Wide-Temperature Range Methane Gas Detection Module is designed for reliable performance in extreme conditions, with an operating temperature range of -20~50℃. It offers a detection range of 0~5000ppm and a fast response time of 0.1 seconds, ensuring accurate methane monitoring. The module features a compact design and a digital interface for easy integration. KACISE combines advanced TDLAS technology with robust construction, making this module ideal for industrial and environmental applications requiring wide-temperature operation.



2.Features

  1. High sensitivity, only responds to the target gas
  2. Built-in reference cell, can be automatically calibrated
  3. Easy to integrate, digital interface directly outputs status and concentration

3.Measuring Principle

"Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
"The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.

4.Technical Parameters

Product model TDLAS200
Detection object Methane (CH4)
Measurement principle Laser absorption spectrum (TDLAS)
Static detection limit 0.5ppm@25℃10SPS (typical value, please contact us for details)
Volume 53ml
Fastest response time 0.1s
Measurement range 0~5000ppm
Measurement deviation

0-200ppm true value +/-2ppm

200-1000ppm true value +/-1%

1000-5000ppm true value +/-2%

12hrs drift +/-1.5ppm
Operating temperature -20~50℃
Power supply 5-12VDC 1W (typical) 3W (maximum)
Dimensions and weight 115×59×38mm
Gas interface Pagoda direct M-5AU-4
Fastest response time Detection time 0.1s

*1 Please ensure that the power input voltage of the module is not less than 5V

*2 Pump selection recommendation <500ml/min

5.Dimensions of the detection module

Dimensions of the detection module host: 115×59×38mm (excluding cables and gas connectors)

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement