Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time | 7 Working days |
Packaging Details | Carton / Wooden box |
Supply Ability | 100 Piece/Pieces per Month |
Pressure | 1.6 Mpa ,2.5Mpa ,4.0Mpa (Special) |
Diameter | DN200 ~ DN2600 |
Temperature | -20°C - +160 °C |
Power Supply | 24VDC, 220VAC |
Communication | RS-485 / MODBUS , HART |
Accuracy | ±1% (Standard) |
Electrode | SUS316,HC,HB,Titanium, Tantalum, etc. |
Output signal | 4~20mA / Pulse / 0~10V |
Installation | Insert |
Protection Class | IP65, IP68(optional) |
Brand Name | KACISE |
Model Number | KEF Series |
Certification | ISO / CE |
Place of Origin | China |
View Detail Information
Explore similar products
Sanitary Type Electromagnetic Flow Meter Smart Water Flow Meter GXEFM2000
Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant
Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC
Flange / Thread Electromagnetic Water Flow Meter With Grounding Rings
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 7 Working days |
Packaging Details | Carton / Wooden box | Supply Ability | 100 Piece/Pieces per Month |
Pressure | 1.6 Mpa ,2.5Mpa ,4.0Mpa (Special) | Diameter | DN200 ~ DN2600 |
Temperature | -20°C - +160 °C | Power Supply | 24VDC, 220VAC |
Communication | RS-485 / MODBUS , HART | Accuracy | ±1% (Standard) |
Electrode | SUS316,HC,HB,Titanium, Tantalum, etc. | Output signal | 4~20mA / Pulse / 0~10V |
Installation | Insert | Protection Class | IP65, IP68(optional) |
Brand Name | KACISE | Model Number | KEF Series |
Certification | ISO / CE | Place of Origin | China |
High Light | wastewater flow meter ,smart water flow meter |
Plug-in Type Electromagnetic Flow Meter With LCD Display
Introduction
The Electromagnetic Flow Meter operates on the principles of Faraday's law of electromagnetic induction, specifically designed for measuring the flow of conductive media within a tube. Here's a rephrased explanation:
The Electromagnetic Flow Meter is a sophisticated instrument based on Faraday's law, meticulously crafted to gauge the flow of conductive substances through a tube. This innovative meter utilizes cutting-edge technology by incorporating a single chip for digital excitation and employs the CAN local fieldbus for enhanced functionality.
This flow meter not only provides local indication of flow parameters but also generates an electrical current signal ranging from 4 to 20mA. This signal serves multiple purposes, including recording, adjustment, and control of the flow. With its versatility and precision, electromagnetic flow meters find extensive application across diverse industrial sectors such as chemical, environmental protection, metallurgy, pharmaceuticals, paper production, and water supply systems.
Features
1. Measurement depends on fluid density, humidity, temperature, pressure and conductivity.
2. There is no obstructive in the conduit and no pressure drop, and the straight pipe required is relatively short.
3. The sensor is equipped with the advanced processing technology that provides excellent immunity to negative pressure.
4. Parameters can be set up using infrared touch nubs no need to open the cover of the converter.
5. Automatic alarm functions for selfdiagnosis, empty load test, high and low limit of flow, two-stage flow value, etc.
Parameters
Pipe diameter | DN200~DN2600 | |
Accuracy | 0.3% (Option), 0.5%, 1.0% of F.S.. | |
Repeatability | Below 0.25% | |
Power | AC: 220V, 50-60Hz; DC: +24V(Option) | |
Output Signals | 4~20mA, Pulse, 0~5V | |
Conduit connection | M20 * 1.5 Thread | |
Communication Interface | RS-232; RS-485; HART | |
Operation Pressure | 1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special) | |
Fluid Temperature | -20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material | |
Ambient Temperature | Sensor -40°C ~80°C. transducer -15°C ~50°C | |
Ambient Humidity | ≤ 85%RH (at 20C) | |
Cable Outlet Size | M20×1.5 | |
Power Supply | 220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years) | |
Power Consumption | ≤ 15W | |
Protection Ratings | Remote type: sensor IP68, transducer IP65. | |
Materials | Electrode | 316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc. |
Liner | PTFE, Soft rubb er, Hard rubber, F46, FS, PUR. | |
Measuring tube | SS 304, carbon steel | |
Flange | Carbon Steal, SS304 | |
Ground ring | 316L (stainless steel), HC, Ti, Ta, Cu. | |
Connection of Flange | National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw. Tri-clamp for sanitary application Insertion type. | |
EX-proof protection | Exde ib ii BT2 | |
Quality control | ISO9001-2008, CE |
Model selection
Application
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!