China KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature
China KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature

  1. China KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature
  2. China KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature
  3. China KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature

KWS630 Online fluorescence Dissolved Oxygen Sensor Automatic Temperature

  1. MOQ: 0-100
  2. Price:
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100
Delivery Time 5-8 work day
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Housing Material POM and 316SS
Operating Temprature 0~45℃,<0.2MPa
Power supply 12~24VDC ±10%
Measuring range 0~20mg/L(0~200%saturation)
Theory Ultraviolet fluorescence method
Accuracy 1%
Output signal RS485
Brand Name Kacise
Model Number KWS630
Certification Intrinsically safe mode E, explosion proof type D, CE
Place of Origin China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100
Delivery Time 5-8 work day Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Housing Material POM and 316SS Operating Temprature 0~45℃,<0.2MPa
Power supply 12~24VDC ±10% Measuring range 0~20mg/L(0~200%saturation)
Theory Ultraviolet fluorescence method Accuracy 1%
Output signal RS485 Brand Name Kacise
Model Number KWS630 Certification Intrinsically safe mode E, explosion proof type D, CE
Place of Origin China (Mainland)
High Light water turbidity sensoroil in water sensor

Online fluorescence dissolved oxygen sensor
 


Introduction

 

The KWS630 fluorescent dissolved oxygen sensor utilizes the fluorescence method for the precise measurement of dissolved oxygen in water. Positioned at the top of the sensor is a film coated with a layer of fluorescent material. In the presence of light emitted by the light-emitting diode, the fluorescent material emits fluorescence upon returning from the stressed state to the ground state. The concentration of dissolved oxygen is determined by measuring the duration of this fluorescence.

 

Additionally, the sensor incorporates a built-in temperature sensor, which automatically compensates for variations in dissolved oxygen values based on temperature changes. This integrated feature enhances the accuracy and reliability of dissolved oxygen measurements by accounting for the influence of temperature on the fluorescence response. The KWS630 fluorescent dissolved oxygen sensor thus offers a robust and efficient solution for monitoring dissolved oxygen levels in water.

 

Features

  1. No electrolyte required, no polarization
  2. No need to consume oxygen, no flow rate
  3. Built-in temperature sensor
  4. Automatic temperature compensation
  5. Free from chemical interferences such as sulfides
  6. Small drift, fast response, more accurate measurement
  7. Maintenance free, longer cycle life and lower cost of ownership
  8. Fluor cap replacement is simple
  9. RS-485 interface, Modbus-RTU protocol

 


 
Technical Specifications

 

product Online fluorescence dissolved oxygen sensor
principle Ultraviolet fluorescence method
Measuring range 0~20mg/L
Response time 10 sec
accurate 1%
Protection level IP68
Deepest depth Underwater 60 meters underwater 10 meters
temperature range 0 ~ 50℃
Output Support RS-485, MODBUS protocol
Power supply DC 5~12V, current <50mA
size Φ26*177.5 mm
Probe cable length 10 m, customizable 5 m, 15 m and 30 m cable
Fluorescent cap life 1 year
Maximum working pressure 6bar
product material POM or 316 ss

 

Installation and electrical connection


1. The temperature sensing part of the installation should be immersed below the liquid level to avoid collision with the surface of the membrane head. The membrane head portion should be protected from deposits.
2. Electrical connection
Red line - power cord (12 ~ 24V)
Black line - ground (GND)
Blue line - 485A
White line - 485B
Bare wire - shield
After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.
Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.
 
Company Information

 

Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.
We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.
Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.
 

Our Services
  • Your inquiry will be replied in 24hours.
  • OEM&ODM, we can help you to design and your request will be put into product.
  • Distributorship are offered for your unique design product and some of our sensors.
  • Protection for your marketting area, ideas of design and all your private information.
  • Discounts are offered based on order quantities.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement