China Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC
China Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC

  1. China Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC

Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC

  1. MOQ: 1pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, T/T, D/P, Western Union, MoneyGram
Supply Ability 1000 Pieces per Week
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Type Sewage Wastewater Flow Meter
output 220VAC Power Supply
Product Electromagnetic Flow Meter
Power supply 220VAC Power Supply
Product name Electromagnetic Flowmeter
Output 4-20mA /RS485/HART/PROFIBUS DP
Brand Name Kacise
Model Number GXEFM2000
Certification certificate of explosion-proof, CE
Place of Origin China (Mainland)

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, T/T, D/P, Western Union, MoneyGram Supply Ability 1000 Pieces per Week
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Type Sewage Wastewater Flow Meter output 220VAC Power Supply
Product Electromagnetic Flow Meter Power supply 220VAC Power Supply
Product name Electromagnetic Flowmeter Output 4-20mA /RS485/HART/PROFIBUS DP
Brand Name Kacise Model Number GXEFM2000
Certification certificate of explosion-proof, CE Place of Origin China (Mainland)
High Light wastewater flow meterelectromagnetic water flow meter

Kacise Digital Sewage Waste Water Electromagnetic Flowmeter with 4-20ma output or Modbus RS485 ​ ​ 

Application field

 

Petroleum, Chemical, Metallurgy, Textile, Papermaking, Environmental protection, Food industry and Municipal administration, Water conservancy construction, Heating heating engineering, River dredging and other fields.

 

 

 

Features Fully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular construction The measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact version With 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range -12…+12m/s /-40...+40ft/s

 

Measuring system

 

Measuring principle Faraday’s law
Application range Electrically conductive fluids
Measured Value
Primary measured value Flow velocity
Secondary measured value Volume flow

 

 

 

Measuring accuracy

 

Reference conditions Flow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

 

  Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter Accuracy Standard: 0.5% of rate
Optional: 0.2% of rate

 

Operating conditions

 

Temperature
Process temperature Hard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperature Standard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature -20~70℃
Pressure
EN 1092-1 DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion length Optional for DN15~600
ASME B16.5 1~24”: 150lb RF
Other pressure on request
JIS DN10~1000/ 2~40”: 10K
Other pressure on request
Pressure drop Negligible

 

Installation conditions

 

Installation Take care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow direction Forward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run ≥5 DN
Outlet run ≥2 DN

 

Process connection

 

Flange
EN1092-1 DN25~3000 in PN6~40
ASME 1~120” in 150 lb RF
JIS 25~1000 in 10~20k
Design of gasket surface RF
  Other sizes or pressure ratings on request

 

Ordering information

 

Model Suffix Code   Description
GXEFM3000 -1200 -Com -4mA -Hart -DC -Pt -Teflon1 -GR -D1400 -Exd IIC T6 Gb  
Diameter -XXXX                   Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter -Com                 Compact type
-Rem                 Remote type
-Bat                 Battery power supply type
-PRO                 process control type
Signal Outpt -N               No output
-4mA               4-20mA
-Pul               1~5KHz pulse
-4Pul               4~20mA / 1~5KHz
Communication -N             No communication
-Hart             HART
-MOD             MODBUS-RTU
-PRO             PROFIBUS
-GPRS             GPRS net
-CDMA             CDMA net
-WHRT             Wireless HART
-Other             special order
Power Supply -AC           85V~250Vac@46~63Hz
nominal 20W
-DC           20~36VDC nominal 20W
-Bat           Battery power supply
-Bat+           Battery +12Vdc dual power supply
Other           special request
Electorde Material -316L         Stainless steel 316L
-HasB         Hastelloy B
-HasC         Hastelloy C276
-Pt         Platinum
-Ta         Tantalum
-Ti         Titanium
-WC         wolfram carbide
Liner material -Rub1       Neoprene(-20-60℃)
-Rub2       Neoprene(-20-90℃)
-Tef1       polytetrafluroethylene(-30-120℃)
-Tef2       polytetrafluroethylene(-20-160℃)
-P       Polyurethane
-FVMQ       FVMQ
-PFA       DFA
-ETFE       Ethylene tetraflurorethylene
Grounding Ring -N     No grounding ring
-GR     Grounding ring
-GE     Grounding Electrode
Wet part Connection attribute -DXX   DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX   AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX   JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF   Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR   Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade -Exd IIC T6 Gb Exd IIC T6 Gb
-N don't need

 

GXEFM2000 Series Electromagnetic Flow Meter

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement