Payment Terms | L/C, D/A, T/T, D/P, Western Union, MoneyGram |
Supply Ability | 1000 Pieces per Week |
Delivery Time | 5-8 work days |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Application range | Electrically conductive fluids |
Type | GXEFM2000 |
Measuring principle | Faraday’s law |
Primary measured value | Flow velocity |
Secondary measured value | Volume flow |
Product | Electromagnetic Flow Meter |
Brand Name | Kacise |
Model Number | GXEFM2000 |
Certification | certificate of explosion-proof, CE |
Place of Origin | China (Mainland) |
View Detail Information
Explore similar products
Sea Water Electromagnetic Flow Meter Transmitter Negative Pressure Resistant
Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC
Flange / Thread Electromagnetic Water Flow Meter With Grounding Rings
12V IP68 WaterProof Magnetic Flow Meter Low Power Consumption Blue Color
Product Specification
Payment Terms | L/C, D/A, T/T, D/P, Western Union, MoneyGram | Supply Ability | 1000 Pieces per Week |
Delivery Time | 5-8 work days | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Application range | Electrically conductive fluids | Type | GXEFM2000 |
Measuring principle | Faraday’s law | Primary measured value | Flow velocity |
Secondary measured value | Volume flow | Product | Electromagnetic Flow Meter |
Brand Name | Kacise | Model Number | GXEFM2000 |
Certification | certificate of explosion-proof, CE | Place of Origin | China (Mainland) |
High Light | wastewater flow meter ,electromagnetic water flow meter |
Description
GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
There are two basic components of electromagnetic flow meter:
1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and
2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.
The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.
Technical Data
Measuring system
Measuring principle | Faraday’s law |
Application range | Electrically conductive fluids |
Measured Value | |
Primary measured value | Flow velocity |
Secondary measured value | Volume flow |
Design
Features | Fully welded maintenance-free sensor |
Flange version with full bore flow tube | |
Standard as well as higher pressure ratings | |
Large diameter range from DN15~3000 with rugged liners approved for drinking water | |
Industry specific insertion lengths | |
Modular construction | The measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version |
Compact version | With 511B converter: 110~240Vac Power |
With 521B converter: 18~36V DC Power | |
With W800L/W800W: Battery Power | |
Remote version | In wall mount version with 211B converter (110~240Vac or 221B converter 18~36V DC |
With W800F converter: Battery Power | |
Measurement range | -12…+12m/s /-40...+40ft/s |
Measuring accuracy
Reference conditions | Flow conditions similar to EN 29104 |
Medium: water | |
Electrical conductivity: ≥300μs/cm | |
Temperature: +10~+30℃/+50~+80℉ |
Inlet setion: ≥5DN | |
Operating pressure: 1Bar/14.5psig | |
Flow Meter Accuracy | Standard: 0.5% of rate |
Optional: 0.2% of rate |
Operating conditions
Temperature | |
Process temperature | Hard rubber liner: -5~+60℃ |
Polypropylene liner: -5~+90℃ | |
PTEF liner: -5~+120℃ | |
Ambient temperature | Standard (with aluminum converter housing) |
-20~+60℃ (Protect electrics against self-heating with ambient temperature above 55℃ | |
Stroage temperature | -20~70℃ |
Pressure | |
EN 1092-1 | DN2200~3000: PN2.5 |
DN1200~2000: PN6 | |
DN200~1000: PN10 | |
DN65~150: PN16 | |
DN10~50: PN40 | |
Other pressure on request | |
ISO insertion length | Optional for DN15~600 |
ASME B16.5 | 1~24”: 150lb RF |
Other pressure on request | |
JIS | DN10~1000/ 2~40”: 10K |
Other pressure on request | |
Pressure drop | Negligible |
Fluid | |
Physical condition | Conductive liquids |
Electrical conductivity | ≥5μs/cm |
Permissible gas content (volume) | ≤5% |
Permissible solid content | ≤70% |
Installation conditions
Installation | Take care that flow sensor is always fully filled |
For detailed information see chapter “Cautions for installation” | |
Flow direction | Forward and reverse |
Arrow on flow sensor indicates positive flow direction | |
Inlet run | ≥5 DN |
Outlet run | ≥2 DN |
Process connection
Flange | |
EN1092-1 | DN25~3000 in PN6~40 |
ASME | 1~120” in 150 lb RF |
JIS | 25~1000 in 10~20k |
Design of gasket surface | RF |
Other sizes or pressure ratings on request |
Ordering information
Model Suffix Code | Description | ||||||||||
GXEFM3000 | -1200 | -Com | -4mA | -Hart | -DC | -Pt | -Teflon1 | -GR | -D1400 | -Exd IIC T6 Gb | |
Diameter | -XXXX | Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm | |||||||||
Transmitter | -Com | Compact type | |||||||||
-Rem | Remote type | ||||||||||
-Bat | Battery power supply type | ||||||||||
-PRO | process control type | ||||||||||
Signal Outpt | -N | No output | |||||||||
-4mA | 4-20mA | ||||||||||
-Pul | 1~5KHz pulse | ||||||||||
-4Pul | 4~20mA / 1~5KHz | ||||||||||
Communication | -N | No communication | |||||||||
-Hart | HART | ||||||||||
-MOD | MODBUS-RTU | ||||||||||
-PRO | PROFIBUS | ||||||||||
-GPRS | GPRS net | ||||||||||
-CDMA | CDMA net | ||||||||||
-WHRT | Wireless HART | ||||||||||
-Other | special order | ||||||||||
Power Supply | -AC | 85V~250Vac@46~63Hz nominal 20W | |||||||||
-DC | 20~36VDC nominal 20W | ||||||||||
-Bat | Battery power supply | ||||||||||
-Bat+ | Battery +12Vdc dual power supply | ||||||||||
Other | special request | ||||||||||
Electorde Material | -316L | Stainless steel 316L | |||||||||
-HasB | Hastelloy B | ||||||||||
-HasC | Hastelloy C276 | ||||||||||
-Pt | Platinum | ||||||||||
-Ta | Tantalum | ||||||||||
-Ti | Titanium | ||||||||||
-WC | wolfram carbide | ||||||||||
Liner material | -Rub1 | Neoprene(-20-60℃) | |||||||||
-Rub2 | Neoprene(-20-90℃) | ||||||||||
-Tef1 | polytetrafluroethylene(-30-120℃) | ||||||||||
-Tef2 | polytetrafluroethylene(-20-160℃) | ||||||||||
-P | Polyurethane | ||||||||||
-FVMQ | FVMQ | ||||||||||
-PFA | DFA | ||||||||||
-ETFE | Ethylene tetraflurorethylene | ||||||||||
Grounding Ring | -N | No grounding ring | |||||||||
-GR | Grounding ring | ||||||||||
-GE | Grounding Electrode | ||||||||||
Wet part Connection attribute | -DXX | DXX: D06, D10, D16, D25,D40 D06: DIN PN6: D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc | |||||||||
-AX | AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600# | ||||||||||
-JX | JX: J1, J2, J3 J1: JIS10K; J2: JIS 20K; J3: JIS 30K | ||||||||||
-WF | Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel | ||||||||||
-TR | Tri-Clamp for sanitary type (Body material: stainless steel) | ||||||||||
Explosive-proof grade | -Exd IIC T6 Gb | Exd IIC T6 Gb | |||||||||
-N | don't need |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us