China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 304 Stainless Steel AC220V Turbidity Water Treatment Sensor with installation
China 304 Stainless Steel AC220V Turbidity Water Treatment Sensor with installation

  1. China 304 Stainless Steel AC220V Turbidity Water Treatment Sensor with installation
  2. China 304 Stainless Steel AC220V Turbidity Water Treatment Sensor with installation

304 Stainless Steel AC220V Turbidity Water Treatment Sensor with installation

  1. MOQ: 0-100
  2. Price: $0-$2000
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 100
Delivery Time 10-15 days
Packaging Details Common package or custom package
host:Material PVC
host:Protection Level I65/IP67(customized version)
host:Signal Output 485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA Communication (function option)
host:Installation Method Wall mount
sensor:Supply Voltage DC5V
Brand Name kacise
Model Number KBU601
Certification CE,FDA
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 100
Delivery Time 10-15 days Packaging Details Common package or custom package
host:Material PVC host:Protection Level I65/IP67(customized version)
host:Signal Output 485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA Communication (function option) host:Installation Method Wall mount
sensor:Supply Voltage DC5V Brand Name kacise
Model Number KBU601 Certification CE,FDA
Place of Origin CHINA
High Light AC220V Turbidity SensorIP67 PVC Turbidity Sensor304 stainless steel Turbidity Sensor

Production Introduction


The turbidity meter KXTX00 series,an online measuring instrument designed for the concentration of suspended solids.
The optical system of the turbidimeter consists of a tungsten filament lamp, a 90° detector for monitoring scattered light and a transmission light detector.The turbidimeter microprocessor calculates the signal ratio from the 90° detector and the transmission photodetector.The ratio calculation technique can correct the interference caused by chromaticity and light-absorbing substances (such as activated carbon) and compensate the influence caused by the fluctuation of light intensity, providing long-term calibration stability.The optical system of turbidimeter also requires to reduce the drifting light and improve the accuracy of test.
After the light wave sent by the transmitter on the turbidimeter sensor passes through the absorption, reflection and scattering of the measured objects in the transmission process, part of the transmitted light can illuminate the detector in the direction of 180° and part of the scattered light scatters to the detector in the direction of 90°.The light intensity received on the 180° and 90° direction detector has a certain relationship with the turbidity of the measured sewage, so the turbidity of the sewage can be calculated by measuring the intensity of transmitted light and scattered light.

 
Typical applications


It is used to measure the turbidity of water during the treatment of municipal sewage, industrial wastewater, and industrial slurry.
Measurement of turbidity of backwash water of filter in waterworks.
Turbidity measurement of water and sedimentation tank effluent;Industrial production process,
Water quality of circulating cooling water.
● Using scattered light and transmitted light detection technology
● Optional self-cleaning (air or water flushing) function
● Chinese/English smart menu operation
● Data recording/upload function
● Various automatic calibration functions
● Three sets of relay control switches
● High limit, low limit, hysteresis control
● 4-20MA /RS485 various signal output modes
● Password protection can be set to prevent non-staff misoperation

 
 
Measuring principle
 

Features:
1. The use of multi-beam mutual compensation technology can eliminate measurement errors caused by light window sticking, as well as temperature changes and components
Parts aging and other effects
2. LCD display, Chinese menu operation, stable performance, strong reliability, convenient operation for workers
3. The throw-in sensor is easy to install, has high accuracy, good repeatability and strong anti-interference ability
4. Support 485 communication 4-20mA analog output/support HART protocol/NB.GPRS.LORA communication (function option)
5. Complete product series, with corresponding sensors for different concentration ranges, and wide measurement range.
The sensors of the turbidity meter are mainly divided into three categories according to the different measuring ranges
 
Throw-in single beam sensor is suitable for turbidity measurement less than 1000NTU,
The signal is transmitted and received at a 90° right angle,
Use the scattered light generated by the colloidal particles suspended in water to calculate the turbidity value,
The input sensor is simple to use, easy to install and easy to maintain.


 

PN Range Resolution Precision
KNT500 0.1-400NTU 0.1NTU Accuracy 2% calibration
KNT600 0.1-1000NTU 0.1NTU Accuracy 2% calibration

 
It can also be used to measure the concentration of sludge, support different units, different ranges of customization.
 
 
Turbidity meter size structure diagram


Turbidity meter technical parameters

 

Class Performance parameter
Host Supply Voltage AC220V or DC24V (choose one of the two)
Power Consumption <2W
Display LCD Chinese display/TFT color LCD (customized version)
Measuring range

0~100NTU,0~500NTU,0~5000NTU
0~10000NTU,0~25g/L,0~50g/L

Resolution 0.01NTU,0.1NTU,1NTU,0.01mg/L
Precision 2-3% calibration accuracy
Operating Temperature Transmitter -10~65℃
Material PVC
Protection Level I65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Installation Method Wall mount
Sensor Supply Voltage DC5V
Protection Level ip68
Temperature 0-60℃
Sensor Material 304 stainless steel (input type), PVC (circulation type)
Cable Length Standard 10 meters (extendable)
Operating Temperature 0-60℃
Storage Temperature -10-60℃
Installation Method Bracket drop-in installation / flow-through wall-mounted installation

 
Ordering Information Selection Table

 

Ordering Information Selection Table
KXTX00 PH/ORP analyzer
Power supply DC24V
AC220V
Cable length 5m
10m
15m
20m
Temperature compensation Sensor without temperature compensation
Sensor with temperature compensation
Signal output Only 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KNT600-DC24V--5m-Sensor without temperature compensation-Only 485 Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.

 
Contact us


Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China


 

Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement