Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100 |
Delivery Time | 10-15 days |
Packaging Details | Common package or custom package |
System | Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output; |
Range | 0~4000 NTU |
Pressure | 0.6MPa |
Calibrate | It has been calibrated before delivery and no calibration is needed on site |
Output | 1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user; |
Display | The display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc. |
Brand Name | kacise |
Model Number | KBU601 |
Certification | CE,FDA |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100 |
Delivery Time | 10-15 days | Packaging Details | Common package or custom package |
System | Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output; | Range | 0~4000 NTU |
Pressure | 0.6MPa | Calibrate | It has been calibrated before delivery and no calibration is needed on site |
Output | 1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user; | Display | The display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc. |
Brand Name | kacise | Model Number | KBU601 |
Certification | CE,FDA | Place of Origin | CHINA |
High Light | 316L Water Turbidity Sensor ,Lightning Proof Water Turbidity Sensor ,0.6MPa water quality probe |
KLT900 online Lightning proof enclosure turbidity meter Water quality detection 316L stainless steel sensor
Production Introduction
Because the water contains suspended and colloidal particles, so that the original colorless transparent water turbidity phenomenon, the degree of turbidity is called turbidity.
The unit of turbidity is expressed as "degree", which is equivalent to the degree of turbidity produced by 1L of water containing 1mg SiO2 (or mg aragonite, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1 FTU = 1JTU.Turbidity is an optical effect, the extent to which light is blocked as it passes through the water layer, indicating the water layer's ability to scatter and absorb light.
It is related not only to the content of suspended matter, but also to the composition, particle size, shape and surface reflectivity of impurities in water.
Measuring principle
TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.
Turbidity meter size structure diagram
host size
sensor size
Turbidity meter technical parameters
Performance | value |
System | Menu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output; |
Supply | AC220V (min85V- max265V) 50/60Hz |
Maximum power consumed | 15 VA |
Fuse | 2A /220VAC |
Range | 0~4000 NTU |
Measurement Unit | NTU and mg/L are available. |
Resolution Rate | 0.1NTU |
Accuracy | 2% of the measured value, within 10NTU the error is not greater than 1NTU. |
Display | The display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc. |
Principle | infrared light scattering 90° and 135° |
Output | 1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user; |
Host:Material | ABS+PC |
Host:Protection Level | IP65 |
Sensor Material | 316L stainless steel |
Cable Length | Dedicated shield cable, standard 10 meters (extendable) |
Operating Temperature | 0-50℃ |
Pressure | 0.6MPa |
Calibrate | It has been calibrated before delivery and no calibration is needed on site |
Ordering Information Selection Table
Ordering Information Selection Table | ||
KXTX00 | PH/ORP analyzer | |
Power supply | DC24V | |
AC220V | ||
Cable length | 5m | |
10m | ||
15m | ||
20m | ||
Temperature compensation | Sensor without temperature compensation | |
Sensor with temperature compensation | ||
Signal output | Only 4-20mA | |
Only 485 | ||
Also with 4-20mA , 485 signal output | ||
Special custom signal | ||
KLT500-DC24V--5m-Sensor without temperature compensation-Only 485 | Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication. |
Q&A
How is the NTU standard solution prepared?
Turbidity (NTU) standard solution preparation method
1. Preparation method of 20NTU standard liquid:
Take 50mL of 400NTU standard stock solution and inject it into the volumetric flask. Then take 950mL of pure water and inject it into the volumetric flask, shake and mix it well. The liquid is 20NTU standard liquid.
2. Preparation method of 10NTU standard liquid:
Inject 25mL of 400NTU standard stock solution into the volumetric flask, and then 975mL of pure water into the volumetric flask, shake and mix, and the liquid is 10NTU standard liquid.
3. The standard 10NTU and 20NTU liquid prepared should be used now and stored at room temperature. It will change the next day and cannot be used.
4. 400NTU standard solution cannot be stored at room temperature. Turbidity standard solution should be stored within 1-10 ℃ (stored in the refrigerator).
Contact us
Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us