China factories

China factory - Changzhou Skyerscale Co.,Limited

Changzhou Skyerscale Co.,Limited

  • China,Changzhou ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China High Precision Digital Scale Indicator With LED Display
China High Precision Digital Scale Indicator With LED Display

  1. China High Precision Digital Scale Indicator With LED Display
  2. China High Precision Digital Scale Indicator With LED Display
  3. China High Precision Digital Scale Indicator With LED Display

High Precision Digital Scale Indicator With LED Display

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 500pcs/M
Delivery Time 7~10days
Packaging Details carton
A/D Converter type Sigma-Delta
Display Type LED
Signal output 4-20 mA analog output
Display resolution 3000
Power Supply DC 9V 1A adapter or AC 110-220V 50 Hz
Load cell excitation DC 5V
Brand Name CAISUN
Model Number XK315A2-6
Certification
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 500pcs/M Delivery Time 7~10days
Packaging Details carton A/D Converter type Sigma-Delta
Display Type LED Signal output 4-20 mA analog output
Display resolution 3000 Power Supply DC 9V 1A adapter or AC 110-220V 50 Hz
Load cell excitation DC 5V Brand Name CAISUN
Model Number XK315A2-6 Certification
Place of Origin China
High Light Precision control IndicatorDigital Scale Weighing Controller

High Precision control indicator A2-6 Series Weighing Controller (4~20MA)

Specification

 

A/D Converter type Sigma-Delta
Sample rate 10 times / second (50 times / second optional)
Display resolution 3000
Internal resolution 1,000,000
Load cell excitation DC 5V
Load cell Up to 4 x 350 Ω or 8 x 700 Ω load cell
Display 6-digit 0.4 inch LED
Division

1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/

20/50/100/200/500/0.10/0.20/0.50/0.010/0.020/0.050

Power DC 9V 1A adapter or AC 110-220V 50 Hz
Operating temperature 0℃~40℃
Storage temperature -25℃~55℃
Relative humidity 85% RH
Size 95 × 48 × 110 mm
Weight 0.5 kg
Signal output 4-20 mA analog output
Options

a) Opto-isolated RS232 or RS485

b) 6 relay outputs with 2 opto-isolated inputs that can be used to control the output of relay #1 and #2

 

1. Model Number

XK315A2-6□-□□-□

0 - No interface

1 - Optical -isolated RS232C

2 - Optical -isolated RS485

AC - AC 110-220V 50 Hz available for XK315A2-6A series only

DC - DC 9V 1A adapter

A - Basic model with 4-20 mA analog output

B - Basic model plus 6 relay outputs and 2 opto-isolated inputs

2. Key Functions

* 】 Function Select key or Enter key

【→】 Right key

【→T←】 Tare key or Increment key

【→0←】 Zero key or Decrement key

3. Status

〖→T←〗 On when tare and the weight is net weight

〖→0←〗 On when the weight is zero

〖◣◢〗 On when the weight is stable

4. Error Code

〖 OUEr〗 - when the weight is > 100% FS + 9d

〖-OUEr〗 - when the weight is < - 20d

〖HHHHHH〗 - when zero reference is > +2% FS

〖LLLLLL〗 - when zero reference is < -2% FS

5. Interface Operation

Serial format 8-N-1: 8 data bits, No parity bit, 1 stop bit.

1. Adr=00 - continuous ASCII reverse data output, if weight is -123.45, the output is 54.321-

2. Adr=99 - continuous ASCII regular data output, if weight is -123.45, the output is -123.45

3. Adr=01-98 - data output using ModBus protocol

6. Operation

1. Turn on the indicator, it displays the version number and checks the LED from “0” to “9”

2. Zero

· When the weight is stable between ±2% FS,press【→0←】zero the display and〖→0←〗is on

· When the zero reference is > +2% FS, it displays 〖HHHHHH〗

· When the zero reference is < -2% FS, it displays 〖LLLLLL〗

3. Tare

· When the weight is stable,〖→T←〗is on

· When the weight is greater than zero and stable,〖◣◢〗 is on

· Press【→T←】zero display and〖→T←〗is on

4. Clear Tare

· When the weight is stable and the weight is net weight,〖→T←〗is on

· Press【→T←】clears the tare and〖→T←〗is off

7. Configurations

Operation Display Descriptions
Press【→】 〖000000〗 Go to Calibrations and Configurations menu and enter password 002003

Press【→】

Or【→T←】

〖002003〗

To enter password 002003:

· Press【→】to move blinking digit to the right

· Press【→T←】to increment blinking digit

· Press【→0←】to decrement blinking digit

Press【 * 〖CAL SP〗 In Calibrations menu
Press【 * 〖-SEt-〗 In Configurations menu
Press【→】 〖d 0.01〗 Set division
Press【→T←】 〖d 0.05〗 Press【→T←】or【→0←】to select d
Press【 * 〖 100.00〗 Set FS
Press【→】 〖000000〗 Left most digit is blinking

Press【→】

Or【→T←】

〖0300.00〗 Press a combinations of【→】,【→T←】and【→0←】to select FS
Press【 * 〖FLt 2〗

Set filter. FLt=0-2

The bigger filter will result in slower weight result

Press【→T←】 〖FLt 1〗 Press【→T←】or【→0←】to select filter
Press【 * 〖AUtP00〗

Set zero trace range and zero at start range

AUtP=00 no zero set at start,zero trace range is 0.4d;

AUtP=10 zero at start range 20% FS,zero trace range is 0.4d;

AUtP=20 zero at start range 20% FS,zero trace range is 0.8d;

AUtP=30 zero at start range 20% FS,zero trace range is 1.2d;

AUtP=40 zero at start range 20% FS,zero trace range is 1.6d;

AUtP=50 zero at start range 20% FS,zero trace range is 2.0d;

AUtP=60 zero at start range 20% FS,zero trace range is 2.4d;

AUtP=70 zero at start range 20% FS,zero trace range is 2.8d;

AUtP=80 zero at start range 20% FS,zero trace range is 3.2d;

AUtP=90 zero at start range 20% FS,zero trace is 3.6d;

Press【→】

Or【→T←】

〖AUtP10〗 Press a combinations of【→】,【→T←】and【→0←】to select AUtP
Press【 * 〖Adr 00〗

Enter indicator address

Adr=00 continuous reverse data output

Adr=99 continuous regular data output

Adr=01-98 data output using ModBus protocol

Press【→】

Or【→T←】

〖Adr 12〗 Press a combinations of【→】,【→T←】and【→0←】to select Adr
Press【 * 〖b 2400〗

Set Baud rate

b=1200,2400,4800,9600

Press【→T←】 〖b 9600〗 Press【→T←】or【→0←】to select baud rate
Press【 * 〖L00791〗

Calibrate the 4 mA analog output

L means current output is 4 mA

Press【→】

Or【→T←】

〖L00791〗 Press a combinations of【→】,【→T←】and【→0←】to calibrate the 4 mA analog output
Press【 * 〖H03723〗

Calibrate the 20 mA analog output

H means current output is 20 mA

Press【→】

Or【→T←】

〖H03723〗 Press a combinations of【→】,【→T←】and【→0←】to calibrate the 20 mA analog output
Press【 * 〖 0.00〗 Save all parameters

 

Applications:

 

Electronic platform scale, weighing scale, etc.

 

Advantage:

 

1. High Quality:
We have strict quality control system, all of our products comply with international quality standards and are greatly in a variety of different markets throughtout the world.

2. Outstanding Customer Service
We are a professional manufacturer and exporter committed to weighing equipments research and manufacture.

3. Low MOQ & Fast Delivery:
Small order quantity and flexible payment terms, it can meet your promotional business very well.
Fast delivery, it can meet your urgent needs.

 

Please contact us:
whatsapp/Tel:0086 15995095496
skyer@skyerscale.com
www.floorweighingscales.com

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter

  • Year Established:

    2007

  • Total Annual:

    500-1000

  • Employee Number:

    >100以上

  • Ecer Certification:

    Verified Supplier

  Changzhou Skyerscale Co., Limited (Changzhou JRBao Electronic Manufacturing Co.,Ltd. ) is a professional high-tech enterprise, which is in the field of electronic truck scale, railway scale, weighing systems and electromechanical equipment research, development, product design and manufact...   Changzhou Skyerscale Co., Limited (Changzhou JRBao Electronic Manufacturing Co.,Ltd. ) is a professional high-tech enterprise, which is in the field of electronic truck scale, railway scale, weighing systems and electromechanical equipment research, development, product design and manufact...

+ Read More

Get in touch with us

  • Reach Us
  • Changzhou Skyerscale Co.,Limited
  • Hehua East road,Daixi, Changzhou city, Jiangsu province, China
  • https://www.floorweighingscales.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement